IICRC WRT Exam Questions and Verified Answers
Q: If at any time during the remediation of a cat 3 loss, any materially interested party disagrees
with how the remediation processes will be performed, restorers should __
immediately until the conflict is resolved.
Answer:
STOP
Q: Which property of a material more relates to water vapor passing through or out of it?
Answer:
Permeance
Q: In order to effectively dry wood subfloor beneath vinyl floor, restorers should remove the
Answer:
vinyl floor
Q: When cellulosic insulation gets wet it should be _
Answer:
removed
Q: Gypsum board that is saturated and sagging should safely __ and _.
Answer:
Drained and removed
Q: When inspecting a water damaged structure, techs should inspect all _______
areas
Answer:
potentially affected
Q: Class _ water losses contain the least amount of water absorption and evaporation load where wet, porous materials represent less than 5% of the combined floor, wall and ceiling surface area in the space Answer: 1 Q: Class _ water losses contain a significant amount of water absorption and evaporation load where wet, porous materials represent 5%-40% of the combined, floor, wall and ceiling surface area in the space Answer: 2 Q: The greatest amount of water absorption and evaporation load where wet, porous materials represent more than 40% of the combined wall, floor, and ceiling surface areas and where low evaporation materials or assemblies have absorbed minimal moisture is a Class______
Answer:
3
Q: Water intrusion that involves a significant amount of water absorption bound within low
evaporation materials and may require longer drying times is a class _ Answer: 4 Q: moisture detection equipment should be used to measure and document __________ and ___________________.
Answer:
Moisture content and relative humidity readings.
Q: A _ can be used to determine the extent of water migration in carpet and pad
Answer:
moisture sensor
Q: Thermo-hygrometer
Answer:
measures temperature and humidity
Q: Moisture levels of structural materials are measured and dry standards are determined using
a ___________
Answer:
moisture meter