List the four phases of a planned maintenance service call.
2. What is the purpose of checking the supply voltage both before and after operating the system?
3. Name key safety aspects of combustion appliances that should be checked on a planned maintenance service call.
The correct answer and explanation is:
1. The Four Phases of a Planned Maintenance Service Call
A planned maintenance service call typically consists of the following four phases:
- Pre-Service Inspection – Reviewing system history, checking for visible issues, and preparing tools.
- Operational Testing – Running the system to check performance and identify potential issues.
- Preventive Maintenance & Repairs – Cleaning, adjusting, and replacing worn components as needed.
- Final Testing & Documentation – Verifying system performance, ensuring safety, and recording maintenance actions.
2. Purpose of Checking Supply Voltage Before and After Operating the System
Checking the supply voltage both before and after running the system is essential to ensure proper functionality and prevent damage.
- Before Operation: This confirms that the electrical supply is within the correct voltage range for safe system startup. A low or high voltage can indicate wiring problems, faulty connections, or an issue with the power supply.
- After Operation: This ensures the system does not cause excessive voltage drops or fluctuations, which could indicate an overloaded circuit, failing components, or inefficient electrical consumption. This step also helps diagnose issues like overheating or compressor failure in HVAC systems.
3. Key Safety Aspects of Combustion Appliances to Check in a Planned Maintenance Service Call
During a planned maintenance service call, combustion appliances must be inspected to ensure safety and efficiency. Key safety aspects include:
- Ventilation & Flue System: Ensuring the flue is clear and venting properly to prevent carbon monoxide buildup.
- Gas Leak Detection: Checking gas connections and fittings for leaks to avoid fire hazards or exposure risks.
- Burner & Ignition System: Verifying proper ignition and flame characteristics for complete combustion.
- Heat Exchanger Condition: Inspecting for cracks or damage that could lead to carbon monoxide leaks.
- Safety Controls & Shutoff Valves: Testing pressure switches, flame sensors, and emergency shutoff mechanisms.
By thoroughly checking these aspects, technicians ensure safe operation and prevent hazards such as fire, carbon monoxide poisoning, and equipment failure.