NEIEP 800 Final Exam Version 2 (Latest 2023/ 2024 Update) Questions and Verified Answers| 100% Correct| Grade A
NEIEP 800 Final Exam Version 2 (Latest
2023/ 2024 Update) Questions and Verified
Answers| 100% Correct| Grade A
Q: With wye-delta, reduced current starting is accomplished without the need for . Answer: resistors Q: run buttons should run the platform and sling at leveling speeds only.
Answer:
Temporary
Q: A _ consists of a piston held closed by an adjustable spring and must open at a
certain pressure to prevent any further increase in pressure.
Answer:
relief valve
Q: A lowering valve allows the car to be lowered at a speed not exceeding 20fpm in case
of power failure.
Answer:
manual
Q: As the oil temperature changes, the _ will change as well and will effect the
performance, more specifically, the leveling and approach of the elevator.
Answer:
viscosity
Q: Be sure wellways are properly _ to avoid accidental injury to you, your team or anyone working outside of our industry. Answer: barricaded Q: Barricades around the wellway must be inches high and be capable of withstanding a
__lb force. Answer: 42, 200 Q: A protects you if you come in contact with a hot wire or component and then come in
contact with ground. It opens the circuit and diverts the supplied current to ground.
Answer:
GFCI
Q: A _ is useful for horizontal (side-to-side) pulling of the truss while being
lowered into the wellway.
Answer:
lever hoist
Q: Code specifies the use of anti-slide devices if the outer edge of the deck is greater than
_ inches from the center line of the handrail.
Answer:
12
Q: (True/False) Anti-slide devices must be less than 3/4″ in height, have no sharp corners or
edges and fastened to the deck no closer than 4 inches from the handrail and spaced no greater
than 6ft apart.
Answer:
True
Q: Sometimes referred to as sag switches, _ switches are located within the step
band of both upper and lower truss assemblies and function to prevent a step that is sagging by
more than inch.
Answer:
step level, 1/8
Q: Per code, an installed escalator can exceed the 30 degree angle of inclination by
degree.
Answer:
1
Q: When it comes to moving walks code states that the angle of inclination of the truss from the
horizontal shall not exceed degrees within ft of the entrance or exits and shall not
exceed __ degrees at any point.
Answer:
3, 3, 12
Powered by https://learnexams.com/search/study?query=