Q: What happens to axial resolution when spatial pulse length is decreased?
Answer:
improves
Q: How much will a 3.5 MHz pulse be attenuated after passing through 2 cm of soft tissue?
Answer:
3.5 dB
Q: Propagation speed errors result in
Answer:
improper axial position
Q: Enhancement is caused by
Answer:
weakly attenuating structures
Q: The Doppler shift frequency is
Answer:
directly proportional to the velocity of the reflector

Q: The number of frames per second necessary for a real-time image to be flicker free is
Answer:
more than 15
Q: True/False: The SPTA intensity will always be larger than the SATA intensity.
Answer:
True
Q: The intensity of the ultrasound beam is usually greater at the focal zone because of
Answer:
the smaller beam diameter
Q: If the amplitude is doubled, the intensity is
Answer:
quadrupled
Q: The attenuation for soft tissue is
Answer:
increased with tissue thickness
Q: The acoustic impedance of the matching layer

Answer:
can be chosen to improve transmission into the body
Q: True/False: In a pulse-echo system, the quality factor should be made as large as possible.
Answer:
False
Q: True/False: The beam diameter is constant in the near zone.
Answer:
False
Q: The operating frequency is dependent on
Answer:
thickness of the crystal
Q: The period of an ultrasound wave is
Answer:
the time of one wavelength
Q: The dynamic range of a system is
Answer:
the ratio of smallest to largest power level that the system can handle

Q: True/False: The intensity of an ultrasonic beam can be measured with radiation force
balance.
Answer:
True
Q: Increasing the pulse repetition period
Answer:
increases the maximum depth that can be imaged
Q: Ultrasound bioeffects
Answer:
are not confirmed below 100 mW/cm² SPTA
Q: True/False: No refraction can occur at an interface if the media impedances are equal.
Answer:
False
Q: True/False: Smaller transducers always produce smaller beam diameters.
Answer:
False
Q: True/False: The ultrasound beam profile can be measured with a hydrophone.
Powered by https://learnexams.com/search/study?query=

ARDMS SPI Exam Review (Latest 2023/ 2024 Update) Questions and Verified Answers| 100% Correct| Grade A

red blood cells

Example of nonspecular reflector

decreases

What happens to spatial pulse length when frequency increases?

wavelength

Axial resolution is dependent on?

beam diameter

Lateral resolution is dependent on?

Fraunhofer zone

Where does the beam of an unfocused transducer diverge?

two or more strong reflecting surfaces

Reverberation artifacts are a result of

False

True/False: Grating lobes are essential for the proper operation of a linear phased array.

False

True/False: Electronically steered scanners always produce higher resolution images than do mechanically steered scanners.

True

True/False: An annular array scanner uses mechanical beam steering.

False

True/False: A linear sequenced array cannot be dynamically focused.

registration or B-mode alignment

Which AIUM test object function utilizes all the groups of wires in the AIUM 100 mm test object?

Image: registration or B-mode alignment

axial resolution

Which AIUM test object function utilizes the A group of wires in the AIUM 100 mm test object?

Image: axial resolution

lateral resolution

Which AIUM test object function utilizes the B group of wires in the AIUM 100 mm test object?

Image: lateral resolution

dead zone

Which AIUM test object function utilizes the D group of wires in the AIUM 100 mm test object?

Image: dead zone

depth calibration

Which AIUM test object function utilizes the C or E groups of wires in the AIUM 100 mm test object?

Image: depth calibration

improves

What happens to axial resolution when spatial pulse length is decreased?

3.5 dB

How much will a 3.5 MHz pulse be attenuated after passing through 2 cm of soft tissue?

improper axial position

Propagation speed errors result in

weakly attenuating structures

Enhancement is caused by

directly proportional to the velocity of the reflector

The Doppler shift frequency is

more than 15

The number of frames per second necessary for a real-time image to be flicker free is

True

True/False: The SPTA intensity will always be larger than the SATA intensity.

the smaller beam diameter

The intensity of the ultrasound beam is usually greater at the focal zone because of

quadrupled

If the amplitude is doubled, the intensity is

increased with tissue thickness

The attenuation for soft tissue is

can be chosen to improve transmission into the body

The acoustic impedance of the matching layer

False

True/False: In a pulse-echo system, the quality factor should be made as large as possible.

False

True/False: The beam diameter is constant in the near zone.

thickness of the crystal

The operating frequency is dependent on

the time of one wavelength

The period of an ultrasound wave is

the ratio of smallest to largest power level that the system can handle

The dynamic range of a system is

True

True/False: The intensity of an ultrasonic beam can be measured with radiation force balance.

increases the maximum depth that can be imaged

Increasing the pulse repetition period

are not confirmed below 100 mW/cm² SPTA

Ultrasound bioeffects with an unfocused beam

False

True/False: No refraction can occur at an interface if the media impedances are equal.

False

True/False: Smaller transducers always produce smaller beam diameters.

True

True/False: The ultrasound beam profile can be measured with a hydrophone.

True

True/False: The pulsed-Doppler system yields better depth resolution than the continuous wave (CW) system.

False

True/False: The gray-scale display was made possible when digital scan converters replaced analog scan converters.

False

True/False: Videotape recorders operating at 30 frames per second cannot be used with mechanical real-time units because the fram rate is too slow.

False

True/False: Linear phased array scanners need no form of mechanical focusing because focusing is performed electronically.

True

True/False: The fram rate of real-time scanners depends on the number of lines used to form the image.

True

True/False: It is not possible to steer an annular phased array electronically.

False

True/False: The near zone length should be kept as short as possible.

25%

What percentage of intensity of an ultrasound pulse incident on an interface of 0.25 and 0.75 rayls is reflected?

higher frequency transducers

Axial resolution can be improved by using

longitudinal wave

When particle motion of a medium is parallel to the direction of a wave propagation, the wave being transmitted is called a

0.3 mm

The wavelength in a material having a wave velocity of 1500 m/s emplying a transducer frequency of 5 MHz is

difference in acoustic impedances

The factor that determines the amount of reflection at the interface of two dissimilar materials is

λ = c/ƒ

The equation that describes the relationship among propagation, wavelength, and frequency is

reflection, refraction, mode conversion

What three things can occur when an ultrasonic beam reaches the interface of two dissimilar materials?

equal to the product of density and velocity

The acoustic impedance of a material is

1540 m/s

The average velocity of ultrasonic waves in soft tissue is

False

True/False: Receiver-angle values in CW Doppler analysis do not influence the final Doppler shift.

wave velocity

Refraction occurs because of difference in ______ across an interface between two materials

acoustic impedance

Reflection factor at an interface between two materials depends primarily on the change in ______ across the interface.

medium and mode of vibration

The velocity of sound waves is primarily dependent on

no change

Increasing the frequency of an ultrasonic longitudinal wave will result in ______ in the velocity of that wave.

refraction

The change in direction of an ultrasonic beam, when it passes from one medium to another, in which elasticity and density differ from those of the first medium is called

using a higher frequency transducer

A long near zone can be obtained by

0.75 mm

If a 2 MHz frequency is used in human soft tissue, the wavelength is approximately

impedance

The ratio of particle pressure to particle velocity at a given point within the ultrasonic field is

Doppler shift frequency

What is the following formula used to determine?
(2 × velocity of reflector × original frequency) / velocity of sound

Huygens

The principle that states that all points on a wavefront can be considered as point sources for the production of sperical secondary wavelets was postulated by

tenfold

A 10 dB difference in signal intensity is equivalent to a _______ difference.

threshold, negative, reject level

The level below which signals are not transmitted through an ultrasound receiver system is the

compression

Gray-scale systems typically use _____ as a means of signal dynamic range reduction.

A-mode

The strength of the echo is related to the height of the deflection on the oscilloscope for the ____ display.

suppression, rejection, compression

What are methods of restricting the dynamic range of the signal?

digital

Most of the scan converters currently in use are of the _____ type?

duty factor

The fraction of time that pulsed ultrasound is actually on is the

sensitivity

The ability of an imaging system to detect weak reflections is called

rectangular

What image shape is produced by a linear sequenced array transducer?

magnitude of the voltage spike

The major factor in determining the acoustic power output of the transducer is the

thermal and cavitational

Two primary mechanisms that produce tissue biological effects are

quality factor, Q Factor

The _____ relates bandwidth to operating frequency.

side lobes

The extraneous beams of ultrasound generated from the edges of individual transducer elements and not in the direction of the main ultrasonic beam are called

pulse duration

The product of the period and the number of cycles in the pulse is the

silicon oxide

The substance typically used as a matrix on the imaging surface of an analog scan converter tube is

the reflector surface is small and smooth as compared with wavelength

Specular reflection occurs when

Schlieren

The refractive index of water is slightly altered when a sound beam passes through it, thus causing compression and rarefaction of the water molecules. The phenomenon is the basis for the _____ technique of beam measurement.

reverberation

Artifacts appearing as parallel, equally spaced lines are characteristic of

enhancement

An increase in reflection amplitude from reflectors that lie behind a weakly attenuating structure is called

using a larger diameter transducer

The amount of dispersion in the far field of an ultrasound beam can be decreased by

spatial pulse length

Longitudinal or axial resolution is directly dependent on

Q factor

The transducer _____ is equal to the ratio of the operating frequency to the frequency bandwidth.

Schlieren

The technique that uses an optical system to produce a visible image of an ultrasonic beam is the _____ technique.

blood

Which of the following is the least obstacle to the transmission of ultrasound?
A. MUSCLE
B. FAT
C. BONE
D. BLOOD

dynamic range

The ratio of the largest power to the smallest power that the ultrasound system can handle is the

longitudinal

Ultrasound waves in tissues are called _____ waves.

axial resolution

The row of wires in the middle are used to check

Image: axial resolution

scan C

Which of the diagrams shows correct arm registration?

Image: scan C

dead zone

The row of wires on top is used to check?

Image: dead zone

call for service

While using the AIUM test object to test an articulated-arm scanner you obtain an image similar to scan A. You should

Image: call for service

horizontal caliper check

The row of wires on the bottom is used to check for

Image: horizontal caliper check

lateral resolution

Which of the following CANNOT be checked when the AIUM test object is scanned from the top only?
A. AXIAL RESOLUTION
B. LATERAL RESOLUTION
C. VERTICAL DISTANCE CALIBRATION
D. HORIZONTAL DISTANCE CALIBRATION

gray scale, dynamic range

What parameters CANNOT be evaluated by the AIUM test object?

registration

Scanning a test object from three sides without erasing would be used to check

all the above

When using the AIUM test object, which of the following should be kept constant for comparisons?
A. OUTPUT POWER
B. TGC
C. REJECT
D. TRANSDUCER MHz & FOCUS

all the above

Which of the following type(s) of ultrasound machine can be used with AIUM test object?
A. LINEAR ARRAY
B. STATIC SCANNER
C. PHASED ARRAY
D. ANNULAR ARRAY
E. SECTOR SCANNER

lead zirconate titanate, barium titanate, lithium sulfate, lead metaniobate, ammonium dihydrogen phosphate

Name 5 synthetic piezoelectric materials.

tourmaline, quartz, Rochelle salt

Name 3 natural piezoelectric materials.

oil

Which of the following materials would NOT be suitable as acoustic insulators for transducer backing?
A. CORK
B. RUBBER
C. OIL
D. ARALDITE W/ TUNGSTEN POWDER
E. EPOXY RESIN

mechanical vibration that can be transmitted through matter

Ultrasound can be described as a

subsonic infrasound

If the frequency of sound is below 16 Hz it is called

ultrasound

If the frequency of sound is above 20 kHz it is called

audible sound

If the frequency of sound is between 16 Hz and 20 kHz it is called

ultrasound

Which of the following is not among the spectrum of electromagnetic waves?
A. X-RAYS
B. ULTRASOUND
C. ULTRAVIOLET
D. INFRARED
E. VISIBLE LIGHT

frequency, cycle per second

The term Hertz denotes

electrical energy into mechanical energy and vice versa

An ultrasound transducer converts

battery, loudspeaker, light bulb, human being

Name 4 examples of a transducer

increase or decrease in size depending on the voltage polarity

When electric voltage is applied on both faces of a piezoelectric crystal, the crystal will

five million cycles per second

The abbreviation 5 MHz denotes

reduce pulse duration, improve axial resolution, reduce spatial pulse length

The function of the damping material in the transducer housing is to

1540 m/s

What is the velocity of ultrasound in human soft tissue at 37°C?

time to complete one cycle

in physical science, the word period denotes

motion of particles parallel to the axis of wave propagation

Longitudinal waves are characterized by

motion of particles perpendicular to the axis of wave propagation

Transverse waves are characterized by

compressions

Ultrasound wave propagation causes displacement of particles in a medium. The regions of greatest particle concentration are

rarefactions

Ultrasound wave propagation causes displacement of particles in a medium. The regions of lowest particle concentration are called

pressure

The prefix piezo- is derived from a Greek word that denotes

axial resolution

Other than depth, longitudinal, and range/radial resolution, what is another term for the ability to distinguish two objects parallel to the ultrasound beam?

electrical connector

#123

Image: electrical connector

backing material

#124

Image: backing material

damping material

#125

Image: damping material

tuning coil

#126

Image: tuning coil

housing

#127

Image: housing

face material

#128

Image: face material

piezoelectric ceramic material

# 129

Image: piezoelectric ceramic material

shield

#130

Image: shield

matching layer

#131

Image: matching layer

cathode

#132

Image: cathode

electron gun

#133

Image: electron gun

control grid

#134

Image: control grid

focusing lens

#135

Image: focusing lens

Y-plate

#136

Image: Y-plate

X-plate

#137

Image: X-plate

electron beam

#138

Image: electron beam

evacuated glass

#139

Image: evacuated glass

glass screen

#140

Image: glass screen

lateral resolution

Other than azimuthal, angular, and transverse resolution, what is another term for the ability to distinguish two objects perpendicular to the ultrasound beam?

decrease

If frequency increases, the wavelength will

increase

If frequency decreases, the wavelength will

decrease

As frequency increases, the penetration will

increase

As frequency increases, the resolution will

decrease

As frequency increases, the beam width will

air, bone, BaSO₄

Ultrasound has difficulty in propagating through which of the following?
A. AIR
B. BONE
C. BaSO₄
D. IVP CONTRAST

barium sulfate

Which of the following CANNOT be used as a coupling medium?
A. WATER
B. SALINE
C. BARIUM SULFATE
D. AQUEOUS GELS

attenuation

Progressive weakening of the sound beam as it travels

piezoelectric effect

Piezoelectric crystals subject to pressure resulting in an electrical charge appearing on their surfaces

reverse piezoelectric effect

Mechanical deformation that results from high voltage applied on faces of the crystal, and, as a result, generate ultrasound

attenuation equation

dB = 10 log₁₀ (I₂ / I₁)

energy

A waveform transfers _____ from one point in space to another point in space.

oscillate around an equilibrium point

In a mechanical wave, there are material particles that

distance

Wavelength is a measure of

mechanical

Ultrasonic waves are

impedance

The density of tissue × the speed of sound in tissue

dB

Amplitude is measured in

above 20,000 Hz

The spectrum of ultrasonic frequency is

frequency

Period is inversely proportional to

the received echoes become larger

In a pulse-echo system, as the ultrasound beam becomes more perpendicular to the organ interface

azimuthal

Axial resolution is also known as all of the following except?
A. DEPTH
B. RANGE
C. AZIMUTHAL
D. LONGITUDINAL

bone

Which of the following has the highest sound velocity?
A. SOFT TISSUE
B. BONE
C. AIR
D. WATER

SPTA intensities below 100 mW/cm²

According to the AIUM, no significant biologic effects have been proven in mammals exposed to

the time the pulse is present

Temporal peak intensity is measured at

SATA

Which of the following has the lowest intensity?
A. SPTP
B. SATP
C. SPTA
D. SATA

beam uniformity ratio

Spatial peak intensity / spatial average intensity

1%

The duty factor of a pulsed echo system is normally less than

better axial resolution

A shortened spatial pulse length results in

V = ƒλ

The equation for measuring the relationship among velocity (or propagation speed), frequency, and wavelength is

all the above

Attenuation of an ultrasound beam can occur by which of the following?
A. DIVERGENCE OF A BEAM
B. SCATTERING
C. REFLECTION

dB/cm/MHz

Attenuation coefficient of sound can be defined by which of the following?
A. dB/cm/MHz
B. dB/cm²/Hz
C. cm/Hz/dB
D. m/dB/cm³

broad

If the transducer Q factor is low, the bandwidth will be

reducing the spatial pulse length

Axial resolution can be improved by

spatial pulse length

Axial resolution is primarily affected by

increase transducer frequency

Which of the following will improve both axial and lateral resolution?
A. SHORT PULSE LENGTH
B. NARROW BEAM WIDTH
C. INCREASE BEAM DIAMETER
D. INCREASE TRANSDUCER FREQUENCY

range

All of the following are also known as lateral resolution except?
A. AZIMUTHAL
B. TRANSVERSE
C. RANGE
D. ANGULAR

100%

Continuous wave Doppler has a duty factor of

density × propagation speed

Acoustic impedance formula

rayls

Acoustic impedance is defined by which of the following?
A. RAYONS
B. METERS/dB
C. mW/cm²
D. RAYLS

frequency

Acoustic impedance is not dependent on which of the following?
A. FREQUENCY
B. DENSITY
C. STIFFNESS
D. NONE OF ABOVE

strength of the echo

The height of the vertical spike on the A-mode display corresponds to

M-mode scans

B-mode ultrasound includes all the following except?
A. STATIC SCANS
B. M-MODE SCANS
C. REAL-TIME SCANS
D. ALL THE ABOVE

percentage of reflection

R = [(Z₂ − Z₁) / (Z₂ + Z₁)]² × 100

nearly 100%

The reflection coefficient between water and air is

100% reflected

What happens to the ultrasound beam beyond the critical angle?

less than the wavelength

Rayleigh scattering occurs if the particle dimensions are

particle displacement

One of the acoustic parameters that determines intensity of an ultrasound wave is?
A. WAVEFORM
B. PARTICLE DISPLACEMENT
C. PERIOD
D. POWER

time

Power is defined as energy per unit

lateral resolution

The ability to resolve structures lying perpendicular to the axis of the ultrasound beam is called

Directly with frequency

In most soft tissue, the attenuation coefficient varies approximately?
A. INVERSELY WITH FREQUENCY
B. WITH THE SQUARE OF THE FREQUENCY
C. LOGARITHMICALLY WITH FREQUENCY
D. DIRECTLY WITH FREQUENCY

conversion of ultrasound into heat

Ultrasound absorption in a medium results in

0.5 dB/cm/MHz

The typical value of attenuation in soft tissue is

reverberation

False echoes are produced by

99%

Approximately what percentage of the ultrasound beam will be transmitted between fat and muscle?

multiple point sources

Huygens’ principle describes

weak diffractors

Enhancement occurs posterior to

half-value layer

The role of sound attenuation in tissue is expressed in terms of

propagation speed error

Improper location of an echo may be attributed to

distance to reflector

The range equation explains

angle of incidence = angle of reflection

For a specular reflector

propagation speed

Which of the following is determined by the medium?
A. INTENSITY
B. PERIOD
C. PROPAGATION SPEED
D. AMPLITUDE

force

Which of the following is not an acoustic variable?
A. DENSITY
B. PRESSURE
C. TEMPERATURE
D. FORCE

TGC

Abbreviation for time gain compensation

lower than 1540 m/s

The propagation speed for fat is
A. HIGHER THAN 1540 m/s
B. LOWER THAN 1540 m/s
C. EQUAL TO 1540 m/s
D. CANNOT BE MEASURED

muscle

Which of the following has a propagation speed closest to the average soft tissue?
A. BONE
B. AIR
C. FAT
D. MUSCLE

air fat muscle bone

Arrange the following media in terms of propagation speed from lowest to highest.
BONE, FAT, AIR, MUSCLE

increases

As frequency increases, backscatter

critical angle

The angle at which total reflection occurs is called

second

The pulse repetition frequency is the number of pulses occurring per

unitless

The unit used for the duty factor is

3 dB/cm

The typical value for attenuation coefficient for 6 MHz ultrasound in soft tissue is

perpendicular

Normal incidence occurs when the ultrasound beam travels ____ to the boundary between the two media

acoustic impedance mismatch

The amount of energy transmitted and/or reflected at the boundary between two media depends on

solid

Which of the following has a higher acoustic impedance coefficient?
A. SOLID
B. LIQUID
C. GAS
D. ALL HAVE EQUAL ACOUSTIC IMPEDANCE COEFFICIENT

of medium 2 > medium 1

According to Snell’s law, the transmission angle is greater than the incidence angle if the propagation speed
A. OF MEDIUM 2 > MEDIUM 1
B. OF MEDIUM 1 > MEDIUM 2
C. OF TWO MEDIA ARE EQUAL
D. IS CALCULATED 3 dB DOWN

propagation speed and pulse round-trip time

According to the range equation, what two things are necessary to calculate the distance to the reflector?

diaphragm

The mirror image artifact is commonly seen around what structure?

either a much lower or a much higher acoustic impedance than its surroundings

The comet tail artifact can be seen posterior to an object that has

tissue−gas interface

Which of the following may produce the comet tail artifact?
A. LIVER−KIDNEY INTERFACE
B. SPLEEN−KIDNEY INTERFACE
C. TISSUE−GAS INTERFACE
D. GAS−FLUID INTERFACE

farther than it really is

If the ultrasound beam passes through a mass in the liver that contains fat, how might the diaphragmatic echo posterior to it appear?

increasing damping

Bandwidth can be increased by

all the above

Which of the following will not affect the echo intensity in the image?
A. OUTPUT POWER
B. OVERALL GAIN
C. TIME GAIN CURVE

dynamic range

On some sonographic equipment, adjusting the compression will affect which of the following processes?
A. SLOPE POSITION
B. DYNAMIC RANGE
C. OUTPUT
D. BALANCE

better axial resolution than lateral resolution

Generally, ultrasound transducers have

1000 Hz

The pulse repetition frequency of an ultrasound unit is typically

brightness modulation

B-mode display denotes

99.9%

What percentage of the time is a typical pulsed ultrasound system capable of receiving echoes?

decreases by ½

If the frequency doubles, what happens to the wavelength?

linear-sequenced array

Which of the following does not display a sector format?
A. LINEAR-SEQUENCED
B. ELECTRONIC-PHASED ARRAY
C. MECHANICAL ROTATING WHEEL
D. MECHANICAL WOBBLER

impedance formula

Z = ρV

lead zirconate titanate

Which of the following is most commonly used in ultrasound transducers?
A. LEAD ZIRCONATE TITANATE (PZT)
B. BARIUM SULFATE
C. METANIOBATE
D. QUARTZ

improve lateral resolution

Transmit-delay focusing in a linear array transducer will

frequency

For real-time systems, which of the following is not related to the other?
A. FRAME RATE
B. LINES PER FRAME
C. PULSE REPETITION FREQUENCY
D. FREQUENCY

pulse emitted per second

The pulse repetition frequency is

beam steering

Which of the following is not a role of the pulser?
A. DRIVING THE TRANSDUCER
B. TELLING RECEIVER WHEN ULTRASOUND PULSES ARE PRODUCED
C. TELLING MEMORY WHEN ULTRASOUND PULSES ARE PRODUCED
D. BEAM STEERING

converting the voltage delivered to the receiver from one form to another

Demodulation is a process of

demodulation & compression

Which of the following are not operator adjustable?
A. COMPENSATION & REJECTION
B. AMPLIFICATION & COMPENSATION
C. DEMODULATION & COMPRESSION
D. REJECTION & AMPLIFICATION

lateral resolution

Which of the following varies with distance from the transducer?
A. LATERAL RESOLUTION
B. FREQUENCY
C. AXIAL RESOLUTION
D. SPATIAL PULSE LENGTH

#3

What number is period?

Image: #3

decreasing half-intensity depth

Increasing axial resolution by increasing frequency also results in

reflection

Redirection of a portion of the ultrasound beam from a boundary is called

binary numbers

Digital computers use a special number system called

binary digit

bit denotes

byte

An 8-bit binary number is referred to as

program

Which of the following is not an example of computer hardware?
A. MONITOR
B. PROGRAM
C. DISK DRIVE
D. PRINTER

random access memory

The acronym RAM denotes

read only memory

The acronym ROM denotes

printer

Which of the following is not an input device?
A. KEYBOARD
B. PRINTER
C. DISK DRIVE
D. MAGNETIC DISK

ROM

What is the type of permanent memory that is produced at the time of manufacture and cannot be changed by the computer user?

EPROM

The type of programmable memory that allows the user to write, store, or erase data is called

central processing unit

CPU denotes

8, 16, 32, or 64 bits

The most common binary word length in microprocessors is

128 × 1024 × 8 = 1,048,576

An 8-bit word microcomputer with 128K words of memory can store how many bits of data?

ultraviolet light

The contents of EPROM can be completely erased by what application?

modem

A sonographic image can be transferred from one computer to another by way of

BASIC

The most commonly used programming language for personal computer is

baud rate

The unit for measuring the speed of data communication is called

hard disk

Which of the following disks has the highest storage capacity and fastest access time?
A. 3½-IN MICROFLOPPY DOUBLE DENSITY
B. HARD DISK
C. 5¼-IN MINIFLOPPY
D. 3½-IN MICROFLOPPY HIGH DENSITY

beginner’s all-purpose symbolic instruction code

The acronym BASIC denotes

modem

An electronic device that translates signals from digital into analog and analog into digital

two

Each binary digit in a binary number is represented in memory by a memory element, which at any time is in one of ____ states.

two

In binary numbers, how many values are used for each digit?

11110

The number 30 in binary is

(2⁴ = )16

How many gray levels (echo amplitude levels) can a 4-bit deep digital scan converter store?

6

An ultrasound instrument that could represent 64 shades of gray would require a ____ bit memory

heating, cavitation

Which of the following are effects seen in tissue at high ultrasound intensities?
A. FUSION, IONIZATION
B. HEATING, CAVITATION
C. EXPANSION, ENCRUSTATION
D. REABSORPTION, DEHYDRATION

amplification, compensation, compression, rejection

What are the functions performed by the receiver in the ultrasound machine?

a large amplitude pulse from the transducer

A large amplitude pulse from the pulser results in

transducer and receiver

Voltage pulses from the pulser go to the

pulser, transducer, receiver, image memory, display

The five major components of a pulse-echo ultrasound system are

cutting a curved transducer element (subdicing) and/or using an acoustic lens

Transducers are focused by two major methods: internal focusing and external focusing. These methods can be accomplished by

none; unitless

The unit applied to the Q factor (quality factor) that describes the ratio of operating frequency to bandwidth is called

shadowing

Reduction in echoes from a region distal to an attenuating structure

enhancement

An increase in echoes from a region distal to a weakly attenuating structure or tissue

anechoic

Without echoes

artifact

An echo that does not correspond to the real echo information

echogenic

A structure that possesses echoes

hyperechoic

Echoes of higher amplitude than the normal surrounding tissue

hypoechoic

Echoes of lower amplitude than the normal surrounding tissues

interface

The surface forming the boundary between two media having different acoustic impedance

sonolucent

A tissue or structure that does not have internal echoes (echo-free)

air

The backing material that is usually constructed in a continuous wave Doppler transducer is

surgical, therapeutic, and Doppler

Transducers with continuous wave operation are commonly used in which applications?

water waves

Which of the following waves are visible under normal conditions?
A. WATER WAVES
B. X-RAY WAVES
C. RADIO WAVES
D. SOUND WAVES

a vacuum

Ultrasound CANNOT travel in

wavelength

Lambda (λ) represents

period

The time it takes to complete a single cycle is called

20 Hz

A wave vibration at 20 cycles per second has frequency of

1 MHz

A wave vibrating at 1 million cycles per second has a frequency of

transducer

The device that produces the ultrasound beam is commonly called a

A-mode

A graphic presentation with vertical spikes arising from a horizontal baseline; the height of the vertical spikes represents the amplitude of the deflected echo

B-mode

A 2D image of internal body structures displayed as dots; the brightness of the dots is proportional to the amplitude of the echo; the image is applicable to both real-time and static scanners

M-mode

A graphic presentation of moving structures in a waveform; the display is presented as a group of lines representing the motion of moving interfaces versus time

silicon

Which of the following is NOT an essential part of the cathode-ray tube (CRT)?
A. ELECTRON GUN
B. FLUORESCENT SCREEN
C. SILICON
D. DEFLECTION SYSTEM (HORIZONTAL & VERTICAL PLATES)

vacuum

The CRT used in ultrasound usually encloses

anode

The positively charged CRT terminal is called the

cathode

The negatively charged CRT terminal is called the

beam diameter

The intensity of the ultrasound beam depends on

Huygens’

Whose principal states “All points on an ultrasound waveform can be considered as point sources for the production of secondary spherical wavelets”?

duty factor

The fraction of time that a pulsed ultrasound system is actually producing ultrasound is called the

sector, linear, and annular scanners

Real-time ultrasound instrumentation can be classified as

the compressibility of the medium

The speed at which ultrasound propagates within a medium depends primarily on

reverberation

An artifact that results from a pulse that has traveled two or more round-trip distances between the transducer and the interface is called

gain

The ratio of output of electric power to input electric power is termed

Multipath

What type of artifacts result from echoes that take an indirect path back to the transducer?

analog and digital

A scan converter will accept echo signals from the receiver and store them in the “memory” of the instrument. Identify the types of memory used in scan converters.

preprocessing

To achieve the best possible digital representation of an analog system, the echo signals should undergo

frequency & transducer diameter

Near zone length may be increased by increasing

density

mass divided by volume

propagation

Progression or travel

frequency

number of cycles per unit time

power

rate at which work is done

duty factor

the product of pulse duration and pulse repetition frequency

bandwidth

range of frequencies contained in the ultrasound pulse

impedance

density multiplied by sound propagation speed

absorption

conversion of sound to heat

quality factor

operating frequency divided by bandwidth

intensity

power divided by area

DECREASED EFFICIENCY, SENSITIVITY AND SPL

Which of the following is a true definition for a highly damped transducer?
A. INCREASED EFFICIENCY, SENSITIVITY, AND SPL
B. DECREASED EFFICIENCY, SENSITIVITY, AND SPL
C. INCREASED EFFICIENCY AND SENSITIVITY, BUT DECREASED SPL
D. DECREASED EFFICIENCY, BUT INCREASED SENSITIVITY AND SPL

attenuation

Gain compensation is necessary due to

spectral analysis

The frequency bandwidth may be determined by which of the following?
A. SPECTRAL ANALYSIS
B. SCHLIEREN SYSTEM
C. HYDROPHONE ANALYSIS
D. CATHOD ANALYSIS

analog

This type of scan converter stores any increment of signal amplitude

(2⁵ = 32 then 42/32 =) 1.3 dB/gray level

The gray-scale resolution for a 5-bit digital instrument that has a dynamic range of 42 dB is

(Distance = velocity × time, so 1540 × 0.01 = 15.4 m × 2 =) 30.8 m

If it takes 0.01 second for a pulse emitted by the transducer to reach an echo source of soft tissue, what distance must the pulse travel to be recorded?

edge artifact

An artifact that is produced from interaction of the incident beam with a curved surface and results in an acoustic shadow is referred to as

split image artifact

An artifact that results from refraction of the ultrasound beam at a muscle-fat interface and give rise to double images is called

comet tail artifact

An artifact that would least likely produce a pseudo-mass is

athletic patients and mesomorphic habitus patients

Split image artifact is more noticeable in

gas bubble

What is the least likely cause for a split image artifact?

partial volume effect

The most likely cause for a beam thickness artifact is

beam angle

Beam thickness artifact is primarily dependent on

may be diffuse or specular in appearance

Which of the following is NOT true for side lobe artifact?
A. CAUSED BY MULTIPLE SIDE LOBES OF THE TRANSDUCER
B. APPARENT IN REAL-TIME IMAGE
C. MAY BE DIFFUSE OR SPECULAR IN APPEARANCE
D. NOT VISIBLE ON REAL-TIME IMAGE

metallic surgical clips (or shotgun pellets)

Which of the following is likely to produce a comet tail artifact?
A. BONE INTERFACE
B. METALLIC SURGICAL CLIPS
C. GALLSTONES
D. GAS INTERFACE

comet tail artifact

The most common type of artifact encountered in patients with shotgun wounds is

ring-down artifact

The type of reverberation echo that usually results from a small gas bubble and appears as a high-amplitude echo occurring at regular intervals is called a

can be calculated using Snell’s law

The amount of splitting that occurs in a split image artifact for a given structure

main bang

The first vertical deflection on the A-mode that corresponds to the transducer face is called

annular-array real-time

The type of real-time system that employs a combination of electronic and mechanical means is called

decrease in amplitude of the returning echo

If the amount of acoustic coupling medium is insufficient, what changes could result?

videotape recorder

Which of the following is not a hard copy?
A. X-RAY FILM
B. POLAROID FILM
C. DYE SUBLIMATION COLOR PRINT
D. VIDEOTAPE RECORDER

M-mode

What mode is displayed in this diagram?

Image: M-mode

B-mode

What mode is displayed in this diagram?

Image: B-mode

A-mode

What mode is displayed in this diagram?

Image: A-mode

biologic effects

The effects of diagnostic ultrasound on human soft tissue are called

1.54 mm/µs

The average propagation speed of ultrasound in soft tissue is

slope

What is C?

Image: slope

delay

What is B?

Image: delay

far gain

What is D?

Image: far gain

near gain

What is A?

Image: near gain

attenuation

Progressive weakening of the sound beam as it travels through a medium

bistable

Having two stages

bit

binary digit

cavitation

The production and behavior of bubbles in sound

coupling medium

A liquid placed between the transducer and the skin

damping

A method of reducing pulse duration by electrical or mechanical means

gray scale

The number of intensity levels between black and white

matching layer

Plastic material placed in front of the transducer face to reduce the reflection at the transducer surface

pixel

picture element

static imaging

single-frame imaging

W/cm²

The intensity of ultrasound is measured in

100 mW/cm² SPTA

There is no known adverse biologic effect in tissue at intensities below

spatial peak temporal average

The acronym SPTA denotes

kg/m³

units for density

m/s

units for speed

Hz

units for frequency

J (joules)

units for work

W/cm²

units for intensity

m

units for wavelength

dB

units for attenuation

0.002 W/cm²−0.5 W/cm² SPTA

The general range of intensities in diagnostic ultrasound is

0.5 W/cm²−2.0 W/cm² SPTA

The general range of intensities in therapeutic ultrasound is

ionizing

Which of the following characteristics does NOT apply to diagnostic ultrasound at normal diagnostic intensity levels?
A. NONINVASIVE
B. ATRAUMATIC
C. IONIZING
D. NONTOXIC

heat

The most common result of high intensity ultrasound is

production and behavior of gas bubbles

In the study of bioeffects, cavitation denotes

stable and transient

The two types of cavitation are

Doppler

The instrument used to detect frequency shift is called

specular reflections

Occur when the interface is larger than the wavelength

nonspecular reflections

occur when the interface is smaller than the wavelength

spatial average temporal average

The acronym SATA denotes

spatial peak pulse average

SPPA denotes

static

The mode not applicable to a Doppler instrument is

5 MHz, short focus

Which of the following transducers would be most useful for imaging superficial structures
A. 5 MHz, SHORT FOCUS
B. 3 MHz, LONG FOCUS
C. 5 MHz, LONG FOCUS
D. 2.5 MHz, SHORT FOCUS

3 MHz, long focus

Which of the following transducers would be most useful for good penetration on an obese patient?
A. 5 MHz, SHORT FOCUS
B. 3 MHz, LONG FOCUS
C. 5 MHz, LONG FOCUS
D. 2.5 MHz, SHORT FOCUS

pixel

The digital memory representts a picture element called a

about 16

How many shades of gray can the human eye distinguish?

512 × 512 × 6-bit deep

The most recent digital storage emplys what size memory?

it is subject to aliasing

A disadvantage of pulsed-wave Doppler (PW) relative to continuous-wave Doppler (CW) is that

all the above

Which of the following utilize a TGC?
A. STATIC SYSTEM
B. REAL-TIME SYSTEM
C. BISTABLE SYSTEM

dissipation of heat by conduction

What is the effect of ultrasound absorption on tissues at normal intensity levels?

525

Video monitors normally have how many horizontal lines?

30

How many frames per second are displayed by a video monitor?

60

How many times each second does the electron beam scan each field on a standard video monitor to produce a flicker-free display?

20-25 dB

The dynamic range of the dots on the average oscilloscope or CRT monitor is

number of rows and columns

The term matrix, when referring to digital memory denotes

squares on a checkerboard

Digital memory can be visualized as

echo-free

A region that is anechoic is displayed as

echogenic

A region that is hyperechoic is

impedance

Which of the following cannot be measured by a hydrophone?
A. PRESSURE AMPLITUDE
B. SPL
C. IMPEDANCE
D. INTENSITY

transducer elements

The hydrophone is made up of

growth retardation

Bioeffects at medium intensity levels on laboratory animals have resulted in?

refraction

Which of the following is the least likely cause for attenuation?
A. ABSORPTION
B. REFLECTION
C. REFRACTION
D. SCATTERING

absorption

Conversion of sound to heat

diffraction

Spreading out of the ultrasound beam

scattering

Redirection of the sound beam in several directions

recommended by the transducer manufacturer

The method for sterilizing transducers is

liver interface or cystic structure

An example of an acoustic window is

10

The binary number 1010 equals the decimal number

fluoroscopy

Real-time imaging is similar to

fast

When attempting to identify fetal heart motion, the frame rate of the real-time system should be set at a ______ rate

all transverse scans should be viewed from the patient’s feet

The recommended orientation for a transverse scan.

the patient’s head to the left of the image and feet to the right of image

The recommended orientation for longitudinal scans is

receiver

Demodulation is a function performed by the

ultrasound waves can be polarized

Which of the following statements about ultrasound waves is not true?
A. ULTRASOUND WAVES ARE MECHANICAL VIBRATING ENERGY
B. ULTRASOUND WAVES CAN BE POLARIZED
C. ULTRASOUND WAVES ARE NOT PART OF THE ELECTROMAGNETIC SPECTRUM
D. ULTRASOUND WAVES CANNOT TRAVEL IN A VACUUM

quartz

The transducer crystal most likely to be employed in high-frequency work, above 18 MHz, is

all the above

The advantage that PZT-5 has over other ceramic materials is that it is
A. EASY TO SHAPE
B. EFFECTIVE AT LOW VOLTAGE
C. INEXPENSIVE

PZT-5

The trade name for lead zirconate titanate is

256

How many shades of gray can be displayed using a scan converter with 8 bits per memory element

mechanical sector real-time transducer

The transducer that would be best suited for intercostal scanning is

Ultrasound – no contrast media, Fluoroscopy – potential biologic effects; whereas ultrasound – no known biologic effects at normal intensity level, ultrasound – nonionizing

The difference between real-time ultrasound and fluoroscopy is

hypaque for IVP examination, telepaque for oral cholecystogram

Which contrast media used in x-ray do not obscure the propagation of ultrasound?

acoustic lens

A device used to focus sound beams

picture element

pixel

pie shaped

sector

device that changes sound waves into visible light patterns

acousto-optical converter

side lobe

the portion of the sound beam outside of the main beam

wavefront

imaginary surface passing through particles of the same vibration as an ultrasound wave

unit of impedance

rayl

the ratio between the angle of incidence and the angle of refraction

Snell’s Law

the change in frequency as a result of reflector motion between the transducer and the reflector

Doppler effect

beam diameter

Lateral resolution is equal to

aluminum, Perspex (acrylic plastic), polystyrene

Which of the following materials are used to make acoustic lenses?

a concave/convex mirror, acoustic lenses

Ultrasound beams can be focused and defocused with the use of

0.1−1.5 mm

The normal range of wavelength in medical application is

individual cells

Which of the following cannot be distinguished on diagnostic ultrasound?
A. TISSUE
B. SOLID MASS
C. INDIVIDUAL CELLS
D. MALE / FEMALE GENETALIA

mass per unit volume

Density is defined as

viscosity, frequency, distance

Ultrasound absorption is directly proportional to

no known effect

The confirmed bioeffects on pregnant women with the use of real-time diagnostic instruments is

neurocranial damage

The confirmed bioeffects on pregnant mice exposed to continuous wave ultrasound in a laboratory setting have resulted in

low frequency and high intensity

Which of the following combinations of frequency and intensity would most likely result in cavitation?
A. HIGH FREQUENCY AND LOW INTENSITY
B. LOW FREQUENCY AND HIGH INTENSITY
C. HIGH FREQUENCY AND HIGH INTENSITY
D. INTENSITY HAS NO EFFECT ON CAVITATION

in vivo

living human tissue

in vitro

tissue cultures in a test tube

spectral analysis

A method of analyzing a waveform

viscoelasticity

The property of a medium characterized by energy distortion in the medium and irreversibly converted to heat

rejection

elimination of small amplitude echo

relaxation

a process of acoustic energy absorption

real cell stasis

an in vivo phenomenon characterized by erythrocytes within small vessels stopping the flow and collecting in the low pressure regions of the standing wavefield

acoustic power

energy transported per unit time

all are false or unconfirmed

Which statements about bioeffects are unconfirmed?
A. ULTRASOUND EXPOSURE IN HUMANS IS ACCUMULATIVE
B. MOST HARMFUL BIOEFFECTS THAT OCCURRED IN EXPERIMENTAL CONDITIONS HAVE BEEN CONFIRMED IN HUMANS IN A CLINICAL SETTING
C. INTENSITY, FREQUENCY, AND EXPOSURE TIME USED ON EXPERIMENTAL ANIMALS WERE COMPATIBLE THOSE USED IN A CLINICAL SETTING
D. CONTINUOUS WAVE USED IN EXPERIMENTAL STUDIES GIVES THE SAME TISSUE EXPOSURE AS PULSED ULTRASOUND USED IN A CLINICAL SETTING
E. THE EXPOSURE OF PREGNANT WOMEN TO HIGH INTENSITY LEVELS RESULTED IN GROWTH RETARDATION OF THEIR OFFSPRING

NONE

The number of known human injuries resulting from diagnostic ultrasound exposure is

no distinction

What is the distinction between real-time scans and B-scans?

uninhibited to propagation

Transonic regions are always

static imaging

Which of the following is not related to real-time?

gray scale

Which of the following is not a component of the time-gain compensation (TGC) curve?
A. GRAY SCALE
B. FAR GAIN
C. KNEE
D. DELAY

0.5−4 kHz

The range of pulse repetition frequencies used in diagnostic ultrasound is

wavelength, cycles

The SPL is defined as the product of the ____ multiplied by the number of ____ in a pulse

A-mode, M-mode

Which modes are one dimensional?

some Doppler instruments

Continuous wave ultrasound is used in

Doppler

Which imaging modality is audible?

continuous wave

Which mode requires two crystals: one for transmitting, and one for receiving?

acoustic mirror

# 461

Image: acoustic mirror

piezoelectric crystal

#462

Image: piezoelectric crystal

scanner head

#463

Image: scanner head

motor

#464

Image: motor

0.2−400 mW/cm²

The normal range of intensities used in Doppler instruments is

higher frequency than the incident frequency

If the media boundary is moving toward the source, the reflected sound wave will have

lower frequency than incident frequency

If the media boundary is moving away from the source, the result will be

bidirectional

A Doppler instrument that can distinguish between positive and negative shifts is called

color Doppler is not beneficial

Which statement about Doppler application is not true?
A. COLOR DOPPLER IS NOT BENEFICIAL
B. DOPPLER CAN PRODUCE AUDIBLE SOUND
C. DOPPLER INSTRUMENTS USE BOTH PULSED AND CONTINUOUS WAVE
D. DOPPLER CAN DISPLAY AN IMAGE

near gain

control used to suppress or increase echoes in the near field

far gain

control used to suppress or increase echoes in the far field

slope

control the upward incline of the TGC, used to display an even texture

delay

control used to delay the start of a slope

knee

controls the point where the slope ends

bandwidth

The range of frequencies contained in an ultrasound pulse is called

Q factor, Duty factor

Which quantity is unitless?

fluid-filled mass

Which of the following would be most likely to cause acoustic enhancement?
A. A SOLID MASS
B. A FLUID-FILLED MASS
C. A CALCIFIED MASS
D. A GALLSTONE

calcified mass

Which of the following would be most likely to cause acoustic shadowing?
A. GALLBLADDER
B. FLUID-FILLED MASS
C. CALCIFIED MASS
D. URINARY BLADDER

2

Continuous wave doppler uses how many piezoelectric elements?

30°

The greatest Doppler angle is achieved when the beam strikes a vessel at a ____ angle

20 dB

If the power output of an amplifier is 100 times the power at the input, the gain is

TGC, DGC

Which control is used to minimize the effects of attenuation?

refraction, propagation speed

When an ultrasound beam passes obliquely across the boundary between two materials, ____ will occur if there is a difference in ____ in the two materials.

better axial resolution

A decreased pulse duration leads to

{R = [(75-25) / (75+25)]² = (50/100)² = 0.5² =} 0.25 mW/cm²

What is the reflected intensity from a boundary between two materials if the incident intensity is 1mW/cm² and the impedances are 25 and 75

frequency and diameter

The near zone length of an unfocused transducer depends on

element thickness

The frequency of a transducer depends primarily on

refraction

An ultrasound beam that is normally incident on an interface will experience no

1.54 mm/µs

The average speed of propagation of ultrasound in soft tissue is

(5/500 =) 1%

The duty factor for a system with a pulse duration of 5 µs and a pulse repetition period of 500 µs is

20 kHz

Ultrasound is defined as sound with frequencies above

tissue attenuation

Frequency is a significant factor in

(0.5 × 3.5 = 1.75 × 2 =) 3.5 dB

In a pulse-echo system, a 3.5 MHz beam of 2 cm of tissue will be attenuated by

propagation speed

The characteristic acoustic impedance of a material is equal to the product of the material density and

false

True/False: For a focused transducer, the beam intensity will remain constant through the scan field

70%

For normal incidence, if the intensity reflection coefficient is 30%, the intensity transmission coefficient will be

frequencies

A Fourier transform of a returning echo will result in a presentation of the ____ contained within the echo

distance, velocity, and time

The range equation relates

SPL

The axial resolution of a system is determined by

90°

The Doppler shift frequency is zero when the angle between the receiving transducer and the flow direction is

false

True/False: The frame rate of real-time scanner that uses an electronic array will be limited only by the speed of the scan converter memory.

the ratio of the maximum to the minimum intensity that can be processed

The dynamic range of a pulse-echo ultrasound system is defined as

smaller

The digital scan converter will generally have a dynamic range that is ____ than other components of the system

compensates for attenuation effects

The time-gain or depth-gain compensation control

computer memory

A digital scan converter is essentially a

false

True/False: A mechanical real-time scanner will always produce images at a slower frame rate than does an electronic real-time scanner.

weakly attenuating structures

Acoustic enhancement can be observed when scanning

false

True/False: Changes in the preprocessing controls will not affect the numbers stored in the scan converter.

is equal to beam diameter

The lateral resolution of a system

increased frame rate

If the lines per degree in a mechanical sector scanner remain constant, a decreased sector angle can result in

reject control

The threshold control is equivalent to the

too close to

If the actual propagation speed in soft tissue is 1700 m/s, current diagnostic scanners will display a reflector at a location _____ the transducer

some Doppler systems

Continuous-wave (CW) ultrasound is used in

15 dB

If the gain of an amplifier is 18 dB, what will the new gain setting be if the gain setting is reduced by one-half?

decreases the maximum depth imaged

Decreasing the pulse repetition period

spatial resolution

The AIUM 100 mm test object measures

false

True/False: Real-time imaging is impossible without electronic arrays.

increase with increased steering angle

Grating lobes in electronic array systems

dB/cm

The attenuation coefficient is expressed in units of

wavelength, velocity, and frequency

The wave equation relates

sensitivity

The ability of a system to detect low-amplitude echoes accurately is referred to as

thermal and cavitation

The primary mechanisms whereby ultrasound can produce biologic effects are

frequency and transducer diameter

The near-zone length of a transducer depends on

no confirmed

The AIUM Committee on Biological Effects (1982) stated that _____ biologic effects have been observed for ultrasound intensities below 100 mW/cm².

focal zone

The intensity of a focused beam is generally highest at the

0.3 mm

The wavelength of a 5 MHz wave passing through soft tissue is approximately

½

An echo that has undergone an attenuation of 3 dB will have an intensity that is ___ its initial intensity.

false

True/False: A pulse-echo system should have a high Q factor (quality factor).

a wide band of frequencies centered at 5 MHz

A 5 MHz transducer used in a pulse-echo system will generally produce

thickness, resonance frequency

The transducer ____ determines its ______.

increased damping, sensitivity

The axial resolution of a transducer can be improved with _____ but at the expense of _____.

piezoelectric

A material that changes its dimensions when an electric field is applied is called ____ material.

matching

The process of making the impedance values on either side of a boundary as close as possible to reduce reflections is called

constructive interference

When the pressure peaks of two waves coincide at a point to produce a new pressure that is larger than either of the two initial waves, the effect is called

highly attenuating structures

Shadowing occurs with

multiple strong reflecting structures

Reverberation artifacts occur with

good axial resolution

a transducer with a large bandwidth is likely to have

Fresnel zone

The near zone is also referred to as

normal

Refraction will not occur at an interface with _____ incidence of the ultrasound beam.

the pulser voltage spike

Acoustic power output is determined primarily by

large and smooth

Specular reflections occur when the reflecting surface is ______ with respect to the wavelength

Snell’s law

The angle at which an ultrasound beam is bent as it passes through a boundary between two different materials is described mathematically by

mechanically

An annular array real-time scanner is steered

90-100%

The percentage of an ultrasound beam reflected at an interface between gas and soft tissue is approximately

1-10%

The percentage of an ultrasound beam reflected at an interface between fat and muscle is approximately

The focal zone can be moved to the skin surface

By using a waterpath offset

longitudinal compression waves; longitudinal mechanical waves

Ultrasound waves in tissue are referred to as

shorter, less

High-frequency transducers have ___ wavelengths and ____ penetration

ring-down time

When the peizoelectric crystal continues to vibrate after the initial voltage pulse, this is referred to as

electronically focus in two dimensions rather than one

Annular phased arrays unlike linear phased arrays

gas, muscle, bone

Arrange in the correct order of increasing propagation speed.
GAS, BONE MUSCLE

resolution, penetration

The lower useful range of diagnostic ultrasound is determined primarily by ____; whereas, the upper useful range is determined by _____.

false

True/False: Color Doppler systems are not subject to aliasing.

SPTP is always ≥ SPTA

Which of the following is true?
A. SPTA IS ALWAYS ≥ SPTP
B. SPTP IS ALWAYS ≥ SPTA
C. SATA IS ALWAYS ≥ SATP
D. SPTA IS ALWAYS ≥ SATP

a hydrophone

A beam-intensity profile is often mapped with

electronic or mechanical

Real-time scanners are generally classified as either

Schlieren method

The technique of passing an ultrasound beam through water so that compression and rarefaction of the water molecules allow the beam pattern to be measured is referred to as the

time

Pulse duration is the _____ for a pulse to occur.

the frequency

The frame rate of a real-time scanner will not depend on

W/cm²

The unit of measure of SPTA is

Curie point

The piezoelectric properties of a transducer will be lost if the crystal is heated above the

increase ninefold

If the amplitude of a wave is increased threefold, the intensity will

false

True/False: A videotape recorder records at a rate of 30 frames/s and therefore cannot be used to record images from a mechanical scanner operating at lower frame rates.

unchanged

If the frequency is increased, the velocity (propagation speed) will be _____.

electronic time-delay pulsing

Beam steering is achieved in a linear phased array by

array based systems

Dynamic focusing is made possible by

false

True/False: Quality assurance measurements are not required with electronic scanners with digital scan converters.

1.54 mm

Sound will travel ____ in 1 µs in soft tissue

ring down artifact

What does the arrow point to?

Image: ring down artifact

rods for measuring “ring-down”

In this image, which represents a tissue-equivalent phantom, the small open arrows point to?

Image: rods for measuring "ring-down"

a simulated solid lesion

What does the curved open arrow point to?

Image: a simulated solid lesion

a simulated cyst

What does the solid black arrow point to?

Image: a simulated cyst

greater range ambiguity artifacts

When the FOV is reduced by decreasing the PRP, the following is more likely to occur

gas-filled bubbles

At the present time, most ultrasound contrast agents are based upon

perfluorocarbon

Microspheres filled with this material is currently used as an ultrasound contrast agent.

higher frequencies

In harmonic imaging, received echoes used for the image have _____ than in ordinary pulse-echo imaging.

better lateral resolution

Harmonic imaging relative to conventional pulse-echo imaging has

steering the beam to achieve larger echoes at a specific image location.

Compounding, in the context of real-time ultrasound scanners, refers to

sources;
https://www.gcu.edu/
https://yaveni.com/
https://www.rasmussen.edu/
https://www.chamberlain.edu/
https://smartu.smartsheet.com/page/smartsheet-certified
https://www.healthstream.com/HLCHelp/Administrator/Reports/Education_Reports/Test_Question_Analysis_Report.htm
https://trailhead.salesforce.com/en/credentials/administrator
https://education.gainsight.com/page/gainsight-certification-programs
https://a.iaabo.org/rules-quizzes/
https://www.ardms.org/get-certified/spi/

Scroll to Top