When potable water is discharged into the drainage system, it shall be through an airgap no less than inch(es). ———- Correct Answer ——— 1
The type of backflow preventer required for a particular application is specified by
. ———- Correct Answer ——— The local code or health department
For a water closet, the first flushometer on a branch line is valued at [a] WSFUs, the
third is valued at [b] WSFUs and the sixth on the branch is valued at [c] WSFUs. ———

  • Correct Answer ——— [a] – 40
    [b] – 20
    [c] – 10
    For urinals, the first flushometer on a branch line is valued [a] WSFUs, the second is
    valued [b] WSFUs and the fourth is valued at [c] WSFUs. ———- Correct Answer ——–
  • [a] – 20
    [b] – 15
    [c] – 8
    To treat a salty flavor in the water, the usual method is to ——— Correct Answer ———
  • install a reverse osmosis system
    Turbidity in water is commonly treated by using ——— Correct Answer ———- a
    diatomaceous earth filter
    If using a solution of at least 50 parts per million of chlorine, you let the system stand for
    ——— Correct Answer ———- 24 hours
    The minimum pipe size for any flushometer valve of any category is __. ———-
    Correct Answer ——— The same as the valve inlet
    The two categories of flushometer valves are [a] and [b]. ———- Correct Answer ———
    [a] – Urinals
    [b] – Water closet
    Water lines within a building shall be tested at not less than [a] with potable water. Or is
    shall be tested with [b] psi of air pressure for not less than [c] minutes. ———- Correct
    Answer ——— [a] – Working pressure
    [b] – 50
    [c] – 15

When sizing a water supply system, you can assume that there will be enough pressure
in the system if adequate pressure is provided to . ———- Correct Answer —–
—- The highest fixture in the system
T/F An atmospheric vacuum breaker may be installed with a valve downstream. ———-
Correct Answer ——— False
An impairment of the quality of the potable water to a degree that does not create a
hazard to the public health but which does adversely and unreasonably affect the
aesthetic qualities of such water for domestic use Also defined as Low Hazard. ———-
Correct Answer ——— Pollution
When branch lines come together with the same categories of flushometer valves,
_
. ———- Correct Answer ——— The fixture unit assignment for the
common pipe will not be the total of those two branch lines
When fixture unit values are calculated for branch lines with flushometer valves, the
valve of the next valve in line in relation to the first valve. ———- Correct
Answer ——— Decreases
Codes require that reverse-osmosis systems drain into the water system through a(n)
___
. ———- Correct Answer ——— air gap
In an ultraviolet-light system, the lamps’s efficiency will be reduced by _. —–
—– Correct Answer ——— Cold water
A commonly used filter in municipal water treatment systems is ___
. ———-
Correct Answer ——— Diatomaceous earth
Resin pellets in a ion-exchange system are saturated with . ———- Correct
Answer ——— Sodium
Scale occurs when the chemical structure of calcium, magnesium, or sodium atoms is
changed by _
. ———- Correct Answer ——— Heat
The process of scouring water to remove particles and chemicals is called
_. ———- Correct Answer ——— Filtration
The two tanks in a typical residential ion-exchange system are . ———-
Correct Answer ——— The resin tank and the brine tank
After a newly installed water supply system has been flushed and disinfected, water
samples should be taken and laboratory-tested for __
. ———- Correct
Answer ——— Harmful bacteria

Distillation systems are effective at eliminating _. ———- Correct Answer —-
—– Hardness
In the above drawing, what is the minimum water meter size? ———- Correct Answer —
——- 1 – 1/2″
A water conditioner should be installed if the iron content tests higher than
___
. ———- Correct Answer ——— 0.2 ppm
An unpleasant smell from water is often due to the presence of _. ———-
Correct Answer ——— Hydrogen sulfide
Iron test kits can also be used to detect ____
. ———- Correct Answer —–
—- Manganese
Most objectionable water tastes and odors, other than metallic flavors, and saltiness,
can be eliminated by using a(n) _. ———- Correct Answer ———
Activated carbon filter
Treat the water supply system if testing reveals sulfur content greater than
_. ———- Correct Answer ——— 1 ppm
Water contaminated with iron and sulfur is often referred to as _. ———-
Correct Answer ——— Black water
The amount of hardness in one grain is _
. ———- Correct Answer ———
17.1 ppm
The principle of osmosis is the solutions tend to seek _. ———- Correct
Answer ——— Equilibrium
An example of a highly effective adsorbent material is
. ———- Correct
Answer ——— Activated carbon
A mathematical process used to accomplish a specific task is known as
. ——
—- Correct Answer ——— Applied mathematics
Combustion air ducts shall . ———- Correct Answer ——— Serve a single
space
Combustion air ducts that terminate in an attic shall
. ———- Correct
Answer ——— Not be screened
Combustion air supplied by using the “standard method” requires a minimum volume of
. ———- Correct Answer ——— 50 cu ft per 1,000 btu/hr
Powered by https://learnexams.com/search/study?query=

5,000
The History of plumbing can be traced back to _ years to the Babylonians

Aqueducts, Baths
The ancient Romans were famous for their _ and public _

Storm
In Western Europe, sewers were constructed in some areas to help control _ water

True
London’s cholera epidemic in the early 1800s was traced to the water supply

In the mid-1800s
When did plumbing as we know it in the US begin to develop?

Roman
The _ Empire was the first to provide large numbers of its citizens with plumbing

True
The Black Plague was directly connected to the lack of sanitary waste disposal

Cholera
Disease traced back to contaminated drinking water

Dark Ages
400-1000 CE

Black Plague
Caused the death of 25 million people

Cholera
A _ epidemic in 1854 killed five percent of Chicago’s population

Most of Chicago’s sewage was dumped into the Chicago river, which flowed into Lake Michigan. Since the lake was the source of drinking water for the city, the water supply became contaminated
Why was Chicago’s water supply contaminated in the mid-1800s?

Registered
A New York law passed in 1881 required that plumbers be _

Sewer Gas, Traps
Early Attempts to install plumbing indoors failed because _ escaped into the house even though — were installed

Venting
The general idea of _ drain/waste piping systems was first used in New York in 1874

1/2″
What size pipe was first used to vent traps in New York City?

Drains
The Greeks’ major contributors to plumbing was the development of bathtubs with _

Asphalt
Bitumen is a natural type of _ that was used to make clay floors waterproof in about 3000 BCE

True
The Romans used lead to make pipe and line sinks and other fixtures

Lead
Plumbum is the Latin word for _

Cast iron pipe
In 1562, _ was used to supply water to a fountain in Germany

Copper pipe, shoe
Early bathtubs were made of _ in the shape of a _

Showers
Evidence of _ has been found in the ruins of Egyptian cities that date back to 1350 BCE

Alexander Cummings
In 1775, _ of England patented the water closet that became the prototype for today’s toilets

William E. Sloan
In 1906, — applied for a patent for the flush valve, which made possible the tankless toilet used in most public restrooms

Firefighting
Boston set up the first waterworks in the US in 1652 to supply water for _ and domestic use

Edwin Ruud
The automatic storage water heater was invented by _

True
Philadelphia became the first city in the to select cast iron for water mains

Zinc
Galvanized pipe is coated with _ metal to prevent rust

False
PVC pipe began to be manufactured during the 19th century

Ditch Witch
The first compact trencher was called the _

1971
Occupied Safety Health Act

1974
Safe Drinking Water Act

1990
Americans with Disabilities Act

National Plumbing Standard
Water efficiency regulations for plumbing fixtures were established by the _

True
Early Christians considered bating to be unsaintly.

Cholera, dysentary, Typhoid
Three diseases caused by contaminated water and lack of sanitary waste disposal in 19th century

330 BCE
The first Roman aquedeucts

False
Outhouses gained acceptance in the early 19th century

1911
First one piece recessed bathtub was manufactured by Kohler in _

Robert Frame, Fred Adee, Charles Neff
Involved in development of siphonic wash-down water closet in early 20th century

1942
First single-handle mixing faucet was patented by Al Moen in _

Wood
Pipes for Boston’s waterworks in 1652 were made of _

New Jersey
The first cast-iron pip was manufactured in _

Light-gauge copper tube and fittings
The development of _ in the 1930s allowed for use of copper for water and DWV in residential buildings

Daniel C. Stillson
Patent for the first pipe wrench in 1870

Roto Rooter
The first sewer cleaning machine

Plumbing enterprises
Employs plumbers

Government agencies
Employs plumbers

Plumbing education
Employs plumbers

Plumbing organizations
Employs plumbers

Plumbing Unions
Employs plumbers

Plumbing contractors associations
Employs plumbers

Enterprises
Plumbing _ serve needs of community, offers greatest opportunity as entry point for beginners

True
Plumbing enterprises include retailers and installation repair services

Functions of government agencies that hire plumbers
Licensing, reviewing plumbing and architectural plans, issuing permits, inspecting installations

True
Plumbing educators are generally master plumbers with many years of experience

Unions
Plumbing _ provide benefits to plumbers, and are source of employees for contractors

Five
Length of most apprenticeships

False
Journeyman plumbers are qualified as contractors

Five
Master plumbers usually required to work for _ years as a journeyman before taking test

Supervisors
responsible for directing work of group of workers

Superintendents
oversee large jobs and have supervisors working under them

Estimators
Responsible for estimating the material and cost of job

Contractors
Master plumbers who hire plumbing personnel to work for them

Most important function of a plumbing supply dealer
Deliver needed materials to job site at the time they are needed

True
One of most important skills that a plumber must acquire is ability to visualize completed system before work is started

Master plumbers
Only plumbers who can obtain plumbing permits

Thinking skills and personal qualities
Three part foundation fundamental to education including basic skills

Reading, writing, mathematics, listening, and speaking
Five skills essential for success in workplace

Measurment
mathematics-related skill most important to plumbers

listening skills
receiving, attending to, interpreting, and responding to verbal messages

Foul language, sexist comments
Types of speech to avoid in workplace

Six thinking skills
reasoning, decision making, visualization, problem solving, creative thinking, and knowing how to learn

Efficient and effective work
Enacted by a plumber’s confidence.

sociability
has the ability to get along with diverse groups

self-management
exercising self-control or self-discipline

integrity
honesty, trustworthiness, dependability

Resources a plumber must effectively manage
time, equipment, tools, materials, supplies

Punctual
arrives and ready to work on time

dependable
follows through on assignments and suggestions for improvement

honesty
truthful with coworkers and supervisors

motivation
gives a fair day’s work for a fair day’s wage

technical ability
performs work with limited ability

leadership
guides others toward completion of work

quality of work
work consistently meets standards

cooperative
works willingly with other plumbers, supervisors and such

False
a family member is a good reference

networking
finding employment opportunities through other people, such as friends.

true
plumbing suppliers are a source of job leads

portfolio
provides documentation of work experience and may contain plans, sketches, photographs, and a list of jobs the plumber has completed

Benefits of part-time, self-employed plumbing
Obtain management experience, develop client base, establish reputation, arrange supply accounts, how to report expenses and income involved in record keeping

Lawyer and accountant
People important to a business owner

Areas of responsibility for government officials involved with plumbing codes
Inspect plans, inspect work during construction, license plumbers

Three part foundation of knowledge skills for success
Basic skills, thinking skills, personal qualities

Basic skills
reading, writing, mathematics, listening, and speaking

Thinking skills
reasoning, decision making, visualization, problem solving, creative thinking, and knowing how to learn

personal qualities
responsibility, self-esteem, sociability, self management, and integrity

Resources
competent use of time, materials, supplies

systems
involving understanding of interrelationships of components

technology
select and use tools and equipment properly

six questions to know if you have all info about a job
who, what, when, where, how, why?

difference between self-employment and running a business
employees

True
Safety is often neglected in plumbing

Carelessness, lack of knowledge, and substance abuse
Contributes to accidents on the job

True
Good housekeeping means keeping the work area clean and orderly

True
safe work habits are formed by the worker’s attitude

True
proper clothing reduces the risk of accident or injury

90%
Percentage of preventable accidents that could have been avoided by wearing proper eye protection according to The National Safety Council

OSHA
Corrective lenses must meet whose safety standards?

Side Shields
Corrective lenses must have these on the job.

False
Loose clothing that is more comfortable is acceptable on the job

False
Pants with cuffs are acceptable on the job

Straight
Your back should be _ when lifting

Leg
Your _ muscles should be used when lifting

True
Repeated strains while lifting can create permanent damage

Hand Slings
Can make carrying large pieces of pipe safer ans easier

Misusing
_ a ladder is one of he most common reasons for ladder injuries

Abusing
_ climbing equipment is one of the most common reasons for injuries.

True
Stepladders are often used for indoor work

Safe load
The duty rating of a ladder is its max _ capacity

Conduct
Aluminum ladders can _ electricity and should not be used near electrical wire

75 degree angle from the ground
extension ladders should placed at what angle from the ground?

2nd step from the top
Never go above this step of a ladder when working

45″
Scaffolds 4′ to 10′ high and less than _ wide must have guard rails

True
Never place a scaffold plank on top of guard rails

Grounded
Electrical tools should be properly _

Ground Fault Circuit Interrupter
GFCI

False
tool guards may be removed for convenience

potential fire hazard
compressed gas cylinders

potential fire hazard
solvents

potential fire hazard
liquid fuel

Class D extinguisher
Combustible metal fires

Class C extinguisher
Electrical equipment fires

Class B extinguiser
Flammable liquid fires

Class A extinguishers
Ordinary combustible material fires

Excavating and trenching work safety
Protecting existing underground utilities

Excavating and trenching work safety
protecting workers in trenches

Excavating and trenching work safety
using hand tools safely

Fall protection
Fall restraint

Fall protection
Fall arrest

Common sense
Hand tool safety

True
Mushroomed heads on chisels and similar tools must not be used

True
Many construction materials are hazardous

Health and physical hazards
Information required to be available to workers

True
Chemical producers are required to label all containers of hazardous materials to identify chemicals and provide warnings

Safety Data Sheet
provides detailed info on each chemical in a product

TLV
Threshold limit value

PEL
Permissible exposure limit

TWA
Time weighted average

STEL
Short term exposure limit

How hazardous materials enter the body
inhaling

How hazardous materials enter the body
ingesting

How hazardous materials enter the body
injecting

How hazardous materials enter the body
absorbing

Respirator
protects workers from inhaling hazardous chemicals

False
one type of respirator works for all conditions

Banana oil
Vials of this substance are used to test the fit of a respirator

Eye protection
Full-face respirators provide what?

Face
Full-face respirators are less likely to leak where?

True
check respirators for leaks or wear before and after each use

False
hearing loss happens only with exposure to very loud sounds

19.5%
the minimum acceptable oxygen level according to NIOSH

No effect, minimum standards
19.5% oxygen

Impaired judgement and breathing
16% oxygen

Faulty judgement, rapid fatigue
14% oxygen

Difficult breathing, death in minutes
6% oxygen

True
Brazing and soldering can generate carbon monoxide in confined spaces

Forced ventilation
required at a minimum when working in a confined space

Hep B, HIV
The two most common bloodborne pathogens

Measuring tools are used to measure
Length, Height, diameter, levelness, and plumbness

Layout tools are used to produce accurate _ _ or any other marking
Lines and Circles

True
Common lengths of long steel measuring tapes are 25′, 50′, 100′, 200′, and 300′

Plumber’s rules are special folding rules available in _ and _
6′, 8′

Combination squares can measure _ angles
both 90 and 45 degree

Three marking tools for various types of pipe
yellow keel, soapstone, pencil

Plumb is to vertical as level is to
horizontal

True
chalk lines are used to lay out long, straight lines on hard and rather smooth surfaces

A _ is an instrument that has a pencil in one leg and is used too lay out circles and arcs.
Compass

Fasle
Files are toothed cutting tools that have one common cross-sectional shape

For best results, the wood chisel is ground to a _ angle
25 degree

A cold chisel is ground to a _ angle
60 degree

Plumber’s augers are available in diameters of _ through _
3/4″, 1-1/2″

Multispur bits, plumbers augers, and _ bits are used for drilling holes
Spade

The operation of _ removes burr that is formed inside a pipe during cutting
Reaming

A _ threading die is a special die used for threading galvanized steel pipe
pipe

_ are sometimes needed to hold plumbing parts while operations are performed on them
Vises

To protect pipe dies when cutting threads, _ is applied to the threads
Cutting oil

True
The three-way pipe die and stock permits three diameters of pipe to be threaded with a single tool

A pipe wrench is used to _ threaded pipe during assembly.
hold or turn

Three basic pipe wrench designs
Straight, end, offset

A __ wrench is used to assemble chrome plated pipe so no damage is done to it
strap

A _ vise is the most common holding device used by plumbers
pipe

A _ hammer is used for driving or pulling nails and for tapping a wood chisel
carpenter’s

A _ screwdriver has two straight and two phillips blades
4-in-1

Plumbers can use all of these for leveling
level, straightedge, chalk line

Also known as a builder’s level
Surveyor’s level

Mounts on a tripod
Builder’s level

A builder’s level rotates
360 degrees

Stadia Rod
graduated stick used to find elevations

Rate of fall
difference in elevation divided by length of run

Horizontal cross hair in builder’s level telescope
used to make reading of measurement.

Automatic level
Self-adjusting to maintain a horizontal line of sight.

Laser
instrument that amplifies or strengthens light, projecting it as a thin beam

Long-term exposure to laser light beam
may cause eye injury

A worker using a laser
Must be qualified to operate such equipment

An unattended laser
Should be shut off

Beam Target
What does the laser beam strike when projecting through a pipe during installation

Hydraulics
The study of the characteristics of fluids

The weight of one cubic foot of water
62.4 lbs

As water depth increases
Water pressure increases

Calculate psi at base of a tower
62.4 divided by 144 times the depth of the tower

Pressure in psi at base of a 175′ tower
75.83

Pressure head
Pressure available at some point in the water system measured by the depth of a column of water above the point where the measurement is taken

A 1′ column of water exerts
.43 psi

The effects of friction on water pressure and flow
Must be considered by plumbers

Streamlined flow
produces less friction

Turbulent flow
produces more friction

Grade L copper pipe
Comparing schedule 40 plastic pipe and grade l copper, which has less head loss?

Water hammer
Can cause pipes to vibrate and possibly burst

Pneumatics
The study of compressible gases

Upward bend
Likely to cause an air lock in a low-pressure piping system that blocks flow

False
Under normal conditions a sanitary or storm system is completely full of water

Scale drawings
May use fractions of inches to represent feet

Prints
Drawings are frequently called:

May use prints
A building official, contractor, or a supplier

Plot Plan
Location of structure on the lot

Elevation Drawings
Exterior appearance

Floor Plan
Describes arrangement of rooms

Foundation plan
Describe size and shape of footing

Detail drawings
Construction of walls, stairs, and doors

Specifications
A set of instructions that provide info about materials and work quality

Vertical distances
Indicated by a section view for DWV piping

Feet and inches
Dimensions usually used in architectural drawings

6′-11″
83 inches written on prints

Symbols used to indicate limits of particular dimensions
Arrowheads, dots, and diagonal lines

Cast Iron
CI

Clean Out
CO

Cold Water
CW

Hot Water
HW

Dish washer
DW

Floor Drain
FD

Hose Bibb
HB

Galvanized Iron
GI

Plastic
PLAS

Plumbing
PLBG

Lavatory
LAV

Title block
to find correct scale of drawings

Soldered or cemented
symbol with a line and circles on each end

1/4″ or 1mm=50mm
Scale customarily used in building plans

A wall on three sides
A recessed tub has what?

Three types of piping sketches
Plan view, two-dimensional, and isometric

plan view
piping sketch frequently drawn on the job site

Plan view 1
Locate known points

Plan view 2
Lightly draw pipe

Plan view 3
Indicate fitting symbols

Plan view 4
Darken lines and add notes

120 or 30 degrees
Angles where lines converge on an isometric axis from horizontal

Horizontal
Grid paper that is extremely helpful in making an isometric sketch

Natural fiber ropes
used extensively in construction

Manila rope
Made from the fiber of a wild banana plant

American Hemp Rope
80% as strong as no. 1 manila rope

Sisal Rope
60% as strong as no. 1 manila rope

Cotton Rope
50% as strong as no. 1 manila rope

Manufactured fibers from which ropes are made
Nylon, Rayon, Glass

Dacron Fibers
Stronger than hemp

Resist rot and deterioration
Synthetic fiber ropes

What not to do with your ropes
Run across sharp surfaces, allowing to freeze

Hoist standard
Attached to scaffold and permits loads to be lifted by a person at the base of the scaffold

Winch Crane
Hoisting device that is used in large buildings to lift large pipes

Lever hoist
hoisting device that has a ratchet mechanism that causes it to be operated slower than other devices

Paint
what should you not put on a wooden ladder

Extension ladder
has two or more sections that can be extended to adjust length

Stepladder
self supporting, non adjustable, and ranges from 4′ to 16′ in length

Articulated ladder
has hinged joints enabling it to be used in a variety of configurations

The health and safety of the people
minimum standards in buildings are specified to protect

Zoning laws
laws that regulate the type of structure that can be built in a given area

Separate
Within zoning laws, residential, office, and industrial activities are

Building codes
Control quality of building material, quality of work, an the number and type of exits

Separate from each other
Plumbing and electrical codes in a building code are almost always

False
enforcement of the plumbing code is almost always delegated to the national plumbing commission

Plans and specifications
When applying for a building permit, a contractor must submit two copies of what to a building inspector?

False
After a permit is obtained, a construction project will be inspected only after completion

Model codes
These were developed to provide a degree of standardization

A court order
If work being done does not meet codes, building officials can obtain what to stop work?

Local governments, architects, plumbers
All involved in the development of plumbing codes

Adopted by the local government
Before a model plumbing code can be enforced, it must be adopted by the local government

BOCA Basic Building Code
Building Officials ad Code Administrators international Inc.

ICBO Plumbing code
International Conference of building Officials

One-and Two-Family Dwelling Code
Council of American Building Officials

Standard Plumbing Code
Southern Building Code Congress International Inc.

Uniform Plumbing Code
International Association of Plumbing and Mechanical Officials

False
Plumbers have the authority to modify code to meet their needs

Definition of terms used, requirements for plumbing fixtures, requirements for the design of vents
Well-written code components

Three stories
The International Residential Code (IRC) is applicable to plumbing work in townhouses not more than __ in height with a separate means of egress.

101.2
The International Residential Code (IRC) is applicable to plumbing work in townhouses not more than three stories in height with a separate means of egress.

Specifically adopted
The provisions of the appendices do not apply unless __.

101.2
The provisions of the appendices do not apply unless specifically adopted

Cost
In order to safeguard life, health, and property, the IPC does not regulate __

101.3
In order to safeguard life, health, and property, the IPC does not regulate cost

Specific
Where different sections of code specify diff requirements, the __ requirements shall apply

102.1
Where different sections of code specify diff requirements, the specific requirements shall apply

A hazard to property
Existing plumbing systems must be brought into compliance with IPC if system is __

102.2
Existing plumbing systems must be brought into compliance with IPC if system is A hazard to property

More specific
Where code provisions conflict with the referenced standard, the __ provisions shall apply

102.8.1
Where code provisions conflict with the referenced standard, the more specific provisions shall apply

State the reason for disapproval in writing to the applicant
Where the code official finds that a proposed alternative material does not comply with the intent of the code provisions, the code official shall __

105.2
Where the code official finds that a proposed alternative material does not comply with the intent of the code provisions, the code official shall State the reason for disapproval in writing to the applicant

research reports
for materials not specifically covered by the code, supporting data necessary to verify compliance with with the code must include

105.2.1
for materials not specifically covered by the code, supporting data necessary to verify compliance with with the code must include research reports

An approved agency
Tests performed by __ may be required by the code official where there is insufficient evidence of code compliance

105.3.2
Tests performed by an approved agency may be required by the code official where there is insufficient evidence of code compliance

as required for public records
required department records shall be retained

105.3.3
required department records shall be retained as required for public records

chief appointing authority
the code official shall be appointed by the

103.2
the code official shall be appointed by the chief appointing authority

requirements
the prescribed portions of the standards referenced in the IPC and listed in CH 15 are considered

102.8
the prescribed portions of the standards referenced in the IPC and listed in CH 15 are considered requirements

required by state law
the code official shall require construction documents and specifications to be prepared by a registered design professional when

106.3.1
the code official shall require construction documents and specifications to be prepared by a registered design professional when required by state law

a code requirement should be waived
the board of appeals is not authorized to rule on an appeal based on a claim that

109.1
the board of appeals is not authorized to rule on an appeal based on a claim that a code requirement should be waived

2
construction documents for buildings more than __ stories in height shall indicate the materials and methods for maintaining the required fire resistance rating

106.3.1
construction documents for buildings more than 2 stories in height shall indicate the materials and methods for maintaining the required fire resistance rating

for testing plumbing systems
the code official may allow temporary connection to the utility source

110.3
the code official may allow temporary connection to the utility source for testing plumbing systems

that was issued based on inaccurate information
the code official is authorized to suspend or revoke a permit __

106.5.5
The code official is authorized to suspend or revoke a permit that was based on inaccurate information

the period required for retention of public records
where tests are required as evidence of compliance with the code, the test reports shall be retained for __

105.3.3
where tests are required as evidence of compliance with the code, the test reports shall be retained for the period required for retention of public records

Approved
When a plumbing permit is issued, the construction documents shall be stamped

106.5.1
When a plumbing permit is issued, the construction documents shall be stamped Approved

180
generally, one set of approved construction documents shall be retained by the code official for at least _ days following completion of the work

106.5.6
generally, one set of approved construction documents shall be retained by the code official for at least 180 days following completion of the work

0.025
sheathing or wrapping for corrosion protection of pipes must be at least __ inches thick

305.1
sheathing or wrapping for corrosion protection of pipes must be at least 0.025 inches thick

0.0575
when concealed piping requires protection against physical damage, plates shall be not less than _ inches thick

305.6
when concealed piping requires protection against physical damage, plates shall be not less than 0.0575 inches thick

3 inches
when excavating a trench for underground piping installations, rock shall e removed to a depth of at least _ below the bottom of the pipe

306.2.2
when excavating a trench for underground piping installations, rock shall e removed to a depth of at least 3″ below the bottom of the pipe

as determined by local jurisdiction
the minimum burial depth for a building sewer is __

305.4.1
the minimum burial depth for a building sewer is as determined by local jurisdiction

loose soil free from rocks or frozen material
where the bedding for piping installed in a trench consists of backfill, __ is an approved material

306.3
where the bedding for piping installed in a trench consists of backfill, loose soil free from rocks or frozen material is an approved material

6″
the initial backfill over pipe installed in a trench shall be in maximum _ layers of loose earth

306.3
the initial backfill over pipe installed in a trench shall be in maximum 6″ layers of loose earth

12
compaction is required for the first __ inches of backfill above a pipe installed in a trench

306.3
compaction is required for the first 12 inches of backfill above a pipe installed in a trench

a registered design professional
alterations to trusses require written approval of __

307.4
alterations to trusses require written approval of a registered design professional

corrosion
pipes passing through concrete walls require protection from __

305.1
pipes passing through concrete walls require protection from corrosion

2
shield plates required to protect piping installed through notches or bored holes in framing members shall extend a minimum of __ inches above sole plates and below top plates

305.6
shield plates required to protect piping installed through notches or bored holes in framing members shall extend a minimum of 2 inches above sole plates and below top plates

12
for water piping adjacent and parallel to a wall footing, and installed at a depth of 12 inches below the bottom of the footing, the trench shall be located not less than __ inches horizontally from the footing

307.5
for water piping adjacent and parallel to a wall footing, and installed at a depth of 12 inches below the bottom of the footing, the trench shall be located not less than 12 inches horizontally from the footing

international mechanical code IMC
the _ regulates piping materials that are exposed in plenums

307.7
the international mechanical code IMC regulates piping materials that are exposed in plenums

1 1/2″
where concealed copper piping passes through holes bored in wood studs, shield plates are not required if the bored holes are at least __ from the nearest edge of the studs

305.6
where concealed copper piping passes through holes bored in wood studs, shield plates are not required if the bored holes are at least 1 1/2″ from the nearest edge of the studs

2 pipe sizes
a pipe sleeve in a masonry foundation wall shall be at least __ greater than the pipe passing through the wall

305.3
a pipe sleeve in a masonry foundation wall shall be at least 2 pipe sizes greater than the pipe passing through the wall

third-party certification
materials used in plumbing systems must be listed by a __ agency

303.4
materials used in plumbing systems must be listed by a third-party certification agency

building traps
the approved methods for preventing rodents from entering a structure do not include __

304.2,3,4
the approved methods for preventing rodents from entering a structure do not include building traps

12
the minimum burial depth of exterior water service piping is __ inches below grade

305.4
the minimum burial depth of exterior water service piping is 12 inches below grade

36
where the frost line is established at 30″, water service pipe shall be installed a minimum of _ inches below grade

304.5
where the frost line is established at 30″, water service pipe shall be installed a minimum of 36 inches below grade

blocks
the code does not permit the use of __ to support and maintain the grade of drainage piping in a trench

306.2
the code does not permit the use of blocks to support and maintain the grade of drainage piping in a trench

clothes washer
a _ is permitted to discharge to an approved nonpotable water system

301.3
a clothes washer is permitted to discharge to an approved non potable water system

more restrictive
when there is a conflict between the requirements of the code and the manufacturer’s installation instructions, the _ requirements apply

301.7
when there is a conflict between the requirements of the code and the manufacturer’s installation instructions, the more restrictive requirements apply

48″
When installed horizontally, 1 1/4″ polypropylene pipe shall be supported at maximum intervals of __

308.5
When installed horizontally, 1 1/4″ polypropylene pipe shall be supported at maximum intervals of 48″

sway bracing
a horizontal 4″ polypropylene water pipe with compression sleeve joints and two 90-degree turns requires __

308.6
a horizontal 4″ polypropylene water pipe with compression sleeve joints and two 90-degree turns requires sway bracing

3
One 1/2″ CPVC water pipe installed horizontally shall be supported at maximum intervals of __ feet

308.5
One 1/2″ CPVC water pipe installed horizontally shall be supported at maximum intervals of 3 feet

10
Support hangers for 10′ lengths of cast iron soil pipe suspended from a ceiling shall be spaced no more than __ feet

308.5
Support hangers for 10′ lengths of cast iron soil pipe suspended from a ceiling shall be spaced no more than 10 feet

2
PVC pipe installed vertically requires a guide installed midway between required supports for pipe sizes _ inches and smaller

308.5
PVC pipe installed vertically requires a guide installed midway between required supports for pipe sizes 2 inches and smaller

Flashing
which of the following is not specifically allowed for sealing around a pipe that passes through an exterior wall?

315.1
which of the following is not specifically allowed for sealing around a pipe that passes through an exterior wall? (Flashing)

12
When located in a flood hazard area, the top of a potable water well casing without a sealed cover shall extend not less than __ inches above the design flood elevation

309.2
When located in a flood hazard area, the top of a potable water well casing without a sealed cover shall extend not less than 12 inches above the design flood elevation

0.10
When performing an air test on cast iron drain, waste and vent (DWV) piping at a pressure of 5 psi, the test gauge shall be marked at maximum __ psi increments

312.1.1
When performing an air test on cast iron drain, waste and vent (DWV) piping at a pressure of 5 psi, the test gauge shall be marked at maximum 0.10 psi increments

10′
A water test on a building drain requires at least a __ head of water

312.2
A water test on a building drain requires at least a 10′ head of water

permit holder
the __ is responsible for performing tests on plumbing piping systems

312.1
the permit holder is responsible for performing tests on plumbing piping systems

the working pressure of the system
the water supply system test must hold a water pressure not less than __

312.5
the water supply system test must hold a water pressure not less than the working pressure of the system

1
condensate piping must maintain a minimum slope of not less than __ percent

314.2.1
condensate piping must maintain a minimum slope of not less than 1 percent

inside the primary drain pan
when required on downflow HVAC units to prevent damage from condensate, a water level monitoring device must be installed __

314.2.3.1
when required on downflow HVAC units to prevent damage from condensate, a water level monitoring device must be installed inside the primary drain pan

must be individually insulated
for piping bundles in manifold water distribution systems, hot water piping __

308.9
for piping bundles in manifold water distribution systems, hot water piping must be individually insulated

toilet facilities
on construction sites, __ are required for workers

311.1
on construction sites, toilet facilities are required for workers

15
water or air pressure tests on piping systems must be held for not less than _ minutes

312.2,3,4,5,6,7,8,9
water or air pressure tests on piping systems must be held for not less than 15 minutes

50
where water supply systems other than plastic are tested with air, the test pressure shall be not less than __ psi

312.5
where water supply systems other than plastic are tested with air, the test pressure shall be not less than 50 psi

sway bracing
horizontal 6″ PVC drainage piping installed above ground requires __ at a 45-degree change of direction

308.6
horizontal 6″ PVC drainage piping installed above ground requires sway bracing at a 45-degree change of direction

32
cross-linked polyethylene (PEX) piping installed horizontally requires hangers at intervals not greater than __ inches

308.5
cross-linked polyethylene (PEX) piping installed horizontally requires hangers at intervals not greater than 32 inches

10
the building sewer requires testing under not less than a __ foot head of water

312.6
the building sewer requires testing under not less than a 10 foot head of water

2
for other than prefabricated shower bases, a water test at least __ inches deep at the threshold is required for shower liners

312.9
for other than prefabricated shower bases, a water test at least 2 inches deep at the threshold is required for shower liners

3/4
the drain line size for condensate from evaporators and cooling coils shall be not less than __ inch internal diameter

314.2.2
the drain line size for condensate from evaporators and cooling coils shall be not less than 3/4 inch internal diameter

1 1/4
for a condensate drain line serving multiple units with a total equipment capacity of 80 tons of refrigeration, the pipe shall be not less than __ inch pipe diameter

314.2.2
for a condensate drain line serving multiple units with a total equipment capacity of 80 tons of refrigeration, the pipe shall be not less than 1 1/4 inch pipe diameter

3
an auxiliary drain pan shall be at least __ inches larger than the unit it serves

314.2.3
an auxiliary drain pan shall be at least 3 inches larger than the unit it serves

a conspicuous location
condensate drains separate from the primary drain line shall discharge to __

314.2.3
condensate drains separate from the primary drain line shall discharge to a conspicuous location

Construction Documents
All of the written, graphic, and pictorial documents prepared or assembled for describing the design, location and physical characteristics of the elements of the project necessary for obtaining a building permit

Sump
A tank or pit that receives sewage or liquid waste, located below the normal grade of the gravity system and that must be emptied by mechanical means

Fill Valve
A water supply valve opened or closed by means of a float or similar device utilized to supply water to a tank

Building sub-drain
That portion of a drainage system that does not drain by gravity into the building sewer

Developed Length
The length of a pipeline measured along the center line of the pipe and fittings

Indirect waste pipe
A waste pipe that does not connect directly with the drainage system, but discharges into the drainage system through an air break or air gap into a trap fixture, receptor, or interceptor

Drainage system
Piping within a public or private premise that conveys sewage, rainwater, or other liquid wastes to a point of disposal. A drainage system does not include the mains of a public sewer system or a private or public sewage treatment or disposal plant

Subsoil drain
A drain that collects subsurface water or seepage water and conveys such water to a place of disposal

Approved
Acceptable to the code official or other authority having jurisdiction

Area drain
A receptacle designed to collect surface or storm water form an open area

Stack
A general term for an vertical line of soil, waste, vent, or inside conductor piping that extends through at least one story with or without offsets

Pollution
An impairment of the quality of the potable water to a degree that does not create a hazard to the public health but does adversely and unreasonably affect the aesthetic qualities of such potable water for domestic use

Vacuum
Any pressure less than that exerted by the atmosphere

Fixture Branch
A drain serving two or more fixtures that discharges to another drain or to a stack

Flow Pressure
The pressure in the water supply pipe near the faucet or water outlet while the faucet or water outlet is wide open and flowing

Backflow preventer
A device or means to prevent backflow

Trap
A fitting or device that provides a liquid seal to prevent the emission of sewer gases without materially affecting flow of sewage or wastewater through the trap

Sanitary sewer
A sewer that carries sewage and excludes storm, surface, and groundwater

Temperature and pressure relief valve
A combination relief valve designed to function as both a temperature relief, and a pressure relief valve

Water outlet
A discharge opening through which water is supplied to a fixture, into the atmosphere (except into an open tank that is part of the water supply system), to a boiler or heating system, or to any devices or equipment that require water to operate but are not part of the plumbing system

Drainage fixture unit
A measure of the probable discharge into the drainage system by various types of plumbing systems.

Self closing faucet
A faucet containing a valve that automatically closes upon deactivation of the opening means

Unstable ground
earth that does not provide a uniform bearing for the barrel of the sewer pipe between the joints at the bottom of the pipe trench

combination fixture
a fixture combining one sink and laundry tray or a two or three compartment sink or laundry tray in one unit

Backsiphonage
the backflow of potentially contaminated water into the potable water system as a result of the pressure into the potable water system falling below atmospheric pressure of the plumbing fixtures, pools, tanks, or vats connected to the potable water distribution piping

Hot water
water at a temp greater or equal to 110 degrees Fahrenheit

Cross connection
any physical connection or arrangement between two otherwise separate piping systems, one of which contains potable water and the other either water of unknown or questionable safety or steam, gas, or chemical, whereby there exists the possibility of flow from one system to the other with the direction of flow depending on the pressure differential between the two systems

Anti-siphon
A term applied to valves or mechanical devices that eliminate siphonage

interceptor
a device designed and installed to separate and retain for removal, by auto or manual means, deleterious, hazardous, or undesirable matter from normal wastes, while permitting normal sewage or waste to discharge into the drainage system by gravity

flood level rim
the edge of the receptacle form which water flows

Ready access
that which enables a fixture, appliance, or equipment to be directly reached without requiring the removal of any panel, door, or similar obstruction and without the use of a portable ladder, step stool, or similar device

Vacuum Breaker
a type of backflow preventer installed on openings subject to normal atmospheric pressure that prevents backflow by admitting atmospheric pressure through ports to the discharge side of the device

water supply system
the water service pipe, water distribution pipes, and the necessary connecting pipes, fittings, control valves, and all appurtenances in or adjacent to the structure or premises

Building trap
a device, fitting, or assembly of fittings installed in the building drain to prevent circulation of air between the drainage system of the building and the building sewer

flush tank
a tank designed with a fill valve an flush valve to flush the contents of the bowl or usable portion of the fixture

trap seal
the vertical distance between the weir and the top of the dip of the trap

back flow connection
any arrangement whereby back flow is possible

leader
an exterior drain pipe for conveying storm water from roof or gutter drains to an approved means of disposal

fixture supply
the water supply pipe connecting a fixture to a branch water supply pipe or directly to a main water supply pipe

offset
a combination of approved bends that makes to changes in direction bringing one section of the pipe out of line but into a line parallel with the other section

non-potable water
water not safe for drinking, culinary, or personal use

back flow
pressure created by any means in the water distribution system, which by being in excess of the pressure in the water supply mains causes a potential back flow condition

quick closing valve
a valve or faucet that closes automatically when released manually or that is controlled by a mechanical means for fast-action closing

fixture drain
the drain from the trap of a fixture to a junction with any other drain pipe

rough-in
parts of the plumbing system that are installed prior to the installation of fixtures. this includes drainage, water supply, vent piping, and the necessary fixture supports and any fixtures that are built into the structure

vent system
a a pipe or pipes installed to provide a flow of air to or from a drainage system, or to provide a circulation of air within such a system to protect trap seals from siphonage and backpressure

branch
any part of the piping system except for the riser, main, or stack

grease interceptor
plumbing appurtenances that are installed in the sanitary drainage system to intercept free-floating fats, oils, and grease from waste water discharge. continuous separation is accomplished by air entrainment, buoyancy, and interior baffling.

PEMDAS
Parentheses, Exponents,
Multiplication, Division,
Add, Subtract

Area
Length time Width

Perimeter
2(L+W)

Circumference
pi times diameter

Area of a circle
pi times radius(squared)

Area of a triangle
height times base divided by 2

Area of a trapezoid
base plus base times height divided by 2

volume of a square or rectangle
length time width times height

volume of a triangular prism
height, times base, times length, divided by 2

volume of a trapezoidal prism
(b+B)ah/2

volume of a cylinder
pi times radius squared, times height

volume of a trough
pi times radius squared, times height, divided by 2

tempered water
water between 85 and 110 degrees Fahrenheit

Main
The principal pipe artery to which branches are connected

critical level
an elevation reference point that determines the minimum height at which a backflow preventer or vacuum breaker is installed above the flood level rim of the fixture or receptor served by the device

Aspirator
a fitting or device supplied with water or other fluid under positive pressure that passes through an integral orifice or construction causing a vacuum. aspirators are also referred to as suction apparatus, and are similar in operation to an ejector

roof drain
a drain installed to receive water collecting on the surface of a roof and to discharge such water into a leader or conductor

common vent
a vent connecting at the junction of two fixture drains or a fixture branch and serving as a vent for both fixtures

backwater valve
a device or valve installed in the building drain or sewer pipe where a sewer is subject to back flow, and which prevents drainage or waste from backing up into a low level or fixtures and causing a flooding condition

storm sewer
a sewer that coveys rainwater, surface water, subsurface water and similar liquid wastes

water distribution pipe
a pipe within the structure or on the premises that conveys water from the water service pipe or from the meter when the meter is at the structure, to the points of utilization

individual vent
a pipe installed to vent a fixture trap and connects with the vent system above the fixture served or terminates in the open air

approved agency
an established or recognized agency approved by the code official and that is regularly engaged in conducting tests or furnishing inspection services

plumbing
the practice, materials, and fixtures utilized in t he installation, maintenance, extension, and alteration of all piping, fixtures, plumbing appliances, and plumbing appurtenances within or adjacent to any structure, in connection with any sanitary drainage or storm drainage facilities, venting systems, and public or private water supply systems

water heater
any heating appliance or equipment that heats potable water and supplies such water to the potable hot water system

cleanout
an access opening in the drainage system utilized for the removal of obstructions. types of clean outs include removable plug or cap, and a removable fixture or trap

yoke vent
a pipe connecting upward from a soil or waste stack to the vent stack for the purpose of preventing pressure changes in the stack

conductor
a pipe inside the building that conveys storm water fro the roof to a storm or combined building drain

access cover
a removable plate, usually secured by bolts or screws to permit access to a pipe or pipe fitting for the purposes of inspection, repair, or cleaning

Rim
an unobstructed open edge of a fixture

potable water
water free from impurities present in amounts sufficient to cause disease or harmful physiological effects and conforming to bacteriological and chemical quality requirements of the public health service drinking water standards or the regulations of the public health authority having jurisdiction

public sewer
a common sewer directly controlled by public authority

Existing installation
any plumbing system regulated by this code that was legally installed prior to the effective date of this code, or for which a permit to install has been issued

plumbing appurtenance
A manufactured device, prefabricated assembly or an on-the-job assembly of component parts that is an adjunct to the basic piping system and plumbing fixtures

Bathroom group
a group pf fixture consisting of a water closet, lavatory, bathtub, or shower, including or excluding a bidet, and emergency floor drain or both

Waste
The discharge from any fixture, appliance, area, or appurtenance that does not contain fecal matter

Circuit Vent
A vent that connects to a horizontal drainage branch and vents two traps to a maximum of eight traps or trapped fixtures connected into a battery

building sewer
the part of a drainage system that extends from the end of the building drain and conveys the discharge to a public sewer, private sewer, individual sewage disposal system, or other point of disposal

Flow control
a device installed upstream from the interceptor having an orifice that controls the rate of flow through the interceptor and air intake (vent) downstream from the orifice that allows air to be drawn into the flow stream

vertical pipe
any pipe or fitting that makes an angle of 45 degrees or more with the horizontal

effective opening
the minimum cross-sectional area at the point of water supply discharge, measured or expressed in terms of the diameter of a circle or, if the opening is not circular, the diameter of a circle of equivalent cross-sectional area.

Riser
a water supply pipe that extends one full story or ore to convey water to branches or to a group of fixtures

water service pipe
the pipe from the water main or other source of potable water supply, or from the meter when the meter is at the public right of way, to the water distribution system of the building served

supports
devices for supporting and securing pipe, fixtures, and equipment

Drain
any pipe that carries waste water or water-borne wastes in a building drainage system

contamination
an impairment of the quality of the potable water that creates an actual hazard to the public health through poisoning or through the spread of disease by sewage, industrial fluids, or waste

relief vent
a vent whose primary function is to provide circulation of air between drainage and vent systems

stack vent
the extension of a soil or waste stack above the highest horizontal drain connected to the stack

vent stack
a vertical pipe installed primarily for the purpose of providing circulation of air to and from any part of the drainage system

water main
a water supply pipe, or system of pipes, installed and maintained by a city, township, county, public utility company, or other public entity, on public property, in the street, or in an approved dedicated easement of public community use

branch interval
a vertical measurement of distance, 8 feet or more in developed length, between the connections of horizontal branches to a drainage stack

sewage
any liquid waste containing animal or vegetable matter in suspension or solution, including liquids containing chemicals in solution

slope
the fall of a line of pipe in reference to a horizontal plane. in drainage the slope is expressed as the fall in units vertical per units horizontal for a length of pipe

PSF
62.4 x depth

PSI
62.4 x depth / 144

PSI (2)
.43 x pressure head

Gallons
inches cubed ÷ 231

Gallons (2)
ft cubed x 7.48

friction loss
pressure head loss x .43