ARDMS SPI EXAM LATEST REAL EXAM 150
QUESTIONS AND CORRECT ANSWERS|A GRADE
Question 1 A ________ is a B mode operation that provides a cross section of the region of interest
as the sound beam sweeps through the region of interest:
Select one:
- B scan
- A mode
- A scan
- M mode
B scan
Question 2
A "bin" in Doppler spectral analysis represents a:
Select one:
- velocity range
- group of pulses
- sample volume
- pixel
velocity range
Question 3
A 3 bit matrix has a gray shade capacity of:
Select one:
- 3
- 1
- 8
- 16
8
Question 4
A 5 MHz transducer used in a pulse-echo system will generally produce
Select one:
- a wide band of frequencies above 5 MHz
- a wide band of frequencies centered at 5 MHz
- a narrow band of frequencies centered at 5 MHz
- frequencies only at 5 MHz
a wide band of frequencies centered at 5 MHz
Question 5
A 6 bit memory can represent how many shades of gray?
Select one:
- 32
- 12
- 64
- 16
64
Question 6
A binary digit is called a:
Select one:
- Byte
- Bin
- Chip
- Bit
Bit
Question 7
A binary word is called a:
Select one:
- Bin
- Byte
- Chip
- Bit
Byte
Question 8
A change in the frequency of sound relative to the motion of the source and/or the
observer is known as the Doppler:
Select one:
- Shift
- Velocity
- Equation
- Display
Shift
Question 9
A continuous wave transducer is 12 mm. the sound beam width at two near zone length
is:
Select one:
- 9 mm
- 12 mm
- 3 mm
- 6 mm
12 mm Question 10
A continuous wave unfocused transducer is 12 mm. The sound beam width at one near
zone length is:
Select one:
- 12 mm
- 9 mm
- 3 mm
- 6 mm
- mm
Question 11
A digital scan converter:
Select one:
- part of a transducer
- a computer memory
- performs FFT (Fast Fourier Transform)
- part of a receiver
a computer memory
Question 12
A display that is limited to only black and white, with no other shades of gray is called
Select one:
- Binary
- Dynamic
- Bistable
Bistable
Question 13
A Doppler spectrum below the baseline represents blood flow:
Select one:
- Bidirectional flow
- Away from the transducer
- Towards the transducer
- Mirroring
Away from the transducer
Question 14
A hydrophone is used to measure
Select one:
- water energy
- electrical energy
- water levels
- acoustic energy
acoustic energy
Question 15
A method used to unwrap a PW aliased signal is:
Select one:
- Increase transmit frequency
- Decreased PRF
- Zero baseline shift
- Increase the sample gate size
Zero baseline shift
Question 16
A perimeter measurement is a measure of:
Select one:
- volume
- area
- distance
- presssure
Distance
Question 17
A picture element which may hold a binary digit/shade of gray:
Select one:
- Pixel
- Transducer
- Matrix
- Image display
Pixel
Question 18
A reflection will be placed at the correct depth because the ultrasound machine will
utilize the ______ equation:
Select one:
- Doppler