PDF Download
BASIC WASTEWATER OPERATOR PRACTICE EXAM CLASS
3 Actual Qs and Ans - Expert-Verified Explanation -Guaranteed passing score -100 Questions and Answers
-Format: Multiple-choice / Flashcard
Question 1: Production of Volatile Acids
Answer:
What causes the pH to decrease during the anaerobic digestion process?
Question 2: Waste more sludge
Answer:
What should be done when the bio-reactor in an SBR plant is organically overloaded?
Question 3: Oil & Grease
Answer:
Which of the following can be analyzed using composite samples?
Question 4: Normal operation
Answer:
When you install a new packing gland, you notice that there is a slow, steady stream of water coming out of the packing area. What is this an indication of?
Question 5: With a chemical absorbent
Answer:
What is the best way to clean up a polymer spill?
Question 6: H2SO4
Answer:
What is the chemical formula for sulfuric acid?
Question 7: Flush with cold water for 15 minutes
Answer:
What is First-Aid for someone getting chlorine gas in their eyes?
Question 8: Plug valve
Answer:
If you have a lime slurry feed line, what is the best valve to use?
Question 9: Heavier than air
Answer:
Chlorine gas is what?Question 10: Decrease the lag time for pump operation by moving the floats closer together
Answer:
The influent to the treatment plant is septic. It is determined that it is coming from a lift station upstream from the plant. What should the operator do?
Question 11: Stalked ciliates
Answer:
What is the predominant organism in a healthy Activated Sludge Treatment Plant?
Question 12: To prevent contamination of potable water systems
Answer:
How is an air-gap device used?
Question 13: Butterfly Valve
Answer:
What is the best valve for throttling flow?
Question 14: 766 lbs/day
Answer:
Your system serves 2740 people and an industry contributes 300 lbs/day of BOD. How many pounds per day of BOD are received at your plant?
Question 15: Check Valve
Answer:
What is a valve that allows water to flow in one direction only?
Question 16: Disinfection
Answer:
Chlorine is primarily used for what?
Question 17: Increase wasting rate
Answer:
What is the most appropriate method to decrease F:M ratio?
Question 18: Denitrification
Answer:
What is the term used when bacteria convert nitrates and nitrites to nitrogen gas under anoxic conditions?
Question 19: blockage in discharge line
Answer:
What causes reduction in pump discharge rate?
Question 20: Containment and Cleanup
Answer:
What is the main concern when a chemical spill occurs?
Question 21: As an inhibitor solution for the DO analysis using the APHA method
Answer:
What is the purpose for adding Copper Sulfamic Acid?Question 22: To prevent wastewater in the discharge line from flowing back through the pump
Answer:
Why are check valves used in conjunction with centrifugal pumps?
Question 23: Settling in the clarifiers
Answer:
If your activated sludge plant begins to nitrify, what conditions would you expect to decrease?
Question 24: Excessive moisture
Answer:
What is one of the most likely causes of electric motor failure?
Question 25: Flow running too slow through discs
Answer:
In an RBC plant, the microscopic investigation revealed some amoebas and flagellates in the first set of discs; the second set showed free-swimming ciliates and some rotifers; and the third set had blood worms and nematodes. What is this an indication of?
Question 26: sulfur dioxide
Answer:
What chemical is used for de-chlorination?
Question 27: 9090 lbs/day
Answer:
Calculate the pounds per day of chemical dosage with a flow of 5MGD, dosing at a rate of 218 PPM.
Question 28: Decreased settling rate
Answer:
What should an operator expect to occur when flow increases to the secondary clarifiers?