PDF Download
CHT DIALYSIS TEST EXAM QUESTIONS
Actual Qs and Ans - Expert-Verified Explanation -Guaranteed passing score -100 Questions and Answers
-Format: Multiple-choice / Flashcard
Question 1: When assessing a fistula or graft, which of the following needs to be listened
for prior to starting dialysis:
- bruit
- stenosis
- thrill
- steal syndrome
Answer:
- bruit
- Separate billing
- Contract pricing
- Composite rate
- Fee-for-service
Question 2: How are the clinics paid by Medicare for dialysis treatment:
Answer:
- Composite rate
Question 3: How do you determine the direction of blood flow in the access
Answer:
Pressing access 1/2 way and feeling which side has greater pulse
Question 4: What is the purpose of a proportioning system?
- Monitors the dialysate flow rate
- Monitors for blood leaks
- Checks the conductivity of the dialysate
- Make dialysate by mixing fresh concentrate with fixed amounts of treated water
Answer:
- Make dialysate by mixing fresh concentrate with fixed amounts of treated water
- Maintain prescribed blood flow rates
- Tighten all connections
- Monitor patients blood pressure
- Allow the normal saline bag to empty
Question 5: Which of the following is used to prevent air in the bloodlines:
Answer:
- Tighten all connections
- Convection
- Suction
- Surface area
- Irradiation
Question 6: Which of the following is a way to remove solutes:
Answer:
- Convection
Question 7: According to AAMI standards, bacteriologic testing for water and dialysate should
take place:
- Daily
- Weekly
- Monthly
- Yearly
Answer:
- Monthly
- Venous
- Venous and arterial
- Arterial
- Predialyzer pressure
Question 8: Which of the following is a negative pressure:
Answer:
- Arterial
Question 9: Although dialysate delivery systems have back-up monitoring systems, it is critical
that:
- The monitoring systems be checked and calibrated on a schedule recommended by the
- Conductivity and pH be verified by independent meters before each dialysis treatment and
- All alarm systems be tested prior to each dialysis treatment
- All of the above
manufacturer
whenever the dialysate is changed
Answer:
- All of the above
Question 10: The action level for endotoxin level is what
Answer:
- EU/ml
Question 11: Chlorine and chloramines in dialysate can cause what
Answer:
Hemolysis
Question 12: Potassium is found in dialysate, T/F
Answer:
T Question 13: Large amounts of aluminum in water used for dialysate could cause:
- Fever/chills
- Liver problems
- Bone disease
- Diarrhea
Answer:
- Bone disease
- 1,220 mL/hr
- 1,385 mL/hr
- 1,440 mL/hr
- 1,500 mL/hr
Question 14: Based on Mrs. Smith's total amount of fluid to be removed, what is the ultrafiltration rate per hour (mL/hr) for her treatment?
Answer:
- 1,385 mL/hr