• wonderlic tests
  • EXAM REVIEW
  • NCCCO Examination
  • Summary
  • Class notes
  • QUESTIONS & ANSWERS
  • NCLEX EXAM
  • Exam (elaborations)
  • Study guide
  • Latest nclex materials
  • HESI EXAMS
  • EXAMS AND CERTIFICATIONS
  • HESI ENTRANCE EXAM
  • ATI EXAM
  • NR AND NUR Exams
  • Gizmos
  • PORTAGE LEARNING
  • Ihuman Case Study
  • LETRS
  • NURS EXAM
  • NSG Exam
  • Testbanks
  • Vsim
  • Latest WGU
  • AQA PAPERS AND MARK SCHEME
  • DMV
  • WGU EXAM
  • exam bundles
  • Study Material
  • Study Notes
  • Test Prep

FF2 Exam Prep (NATIONAL); Questions and Answers; IFSTA Essentials of Firefighting Exam Prep (For FF2) 2026/2027) (Complete and Verified) (28pages)

exam bundles Sep 16, 2025
Preview Mode - Purchase to view full document
Loading...

Loading study material viewer...

Page 0 of 0

Document Text

A description of conditions as they appear can also be called a Correct Answer-Brief Initial Report The arrival report should contain the Correct Answer-Address of incident if different from original What contains the transfer of command? Correct Answer-Personal accountability report What includes an air consumption report when given? Correct Answer-Tactical progress report What is intended to warn personnel at a scene of an impending hazard? Correct Answer-Emergency radio traffic What would be a systematic method of confirming the status of units operating at incident? Correct Answer-Personal accountability report What is a limitation of a personnel accountability report? Correct Answer-It uses a considerable amount of time What is vital to fire department operations from legal, statistical, and record-keeping standpoints? Correct Answer-Post Incident report Why was the National Fire Incident Reporting System (NFIRS) developed? Correct Answer-To create data for analysis Knowing about types of roofs, roofs supports, and roof coverings can help firefighters: Correct AnswerJudge Roof Safety Which of the size-up indicators is not directly related to building construction Correct Answer-Adjacent exposures What is defined as the maximum heat that can be produced if all combustible material in a given area burns Correct Answer-Fuel Load What BEST describes an outcome of heavy content fuel loading Correct Answer-Fire can overwhelm the capabilities of the fire suppression system What is the critical temperature for steel trusses Correct Answer-1,000oF (538oC) In a bowstring truss roof what is fastened at the truss ends with U-shaped steel heels Correct Answer-Top and bottom chord members Additional fuel loads and ignition sources brought by building contractors are factors that: Correct Answer-Cause the risk of fire to rise sharply Preventative structural collapse potential can be identified during: Correct Answer-Preincident surveys After the emergency part of an incident is over structural collapse potential is: Correct Answer-The same as during the incident Post suppression activities and the buildup of water from suppression increase ______ in the decay state. Correct Answer-Collapse Potential What increases structural collapse potential but may not be visible during pre incident surveys Correct Answer-Storage Every U.S. gallon of water used during fire suppression adds how much pressure to floors Correct Answer8.33 pounds When a collapse is imminent, firefighters should first: Correct Answer-Inform command and all others in the buildings The collapse zone is established: Correct Answer-Adjacent to any exposed exterior walls Which of the following types of constriction is not as likely to collapse Correct Answer-Type I What type of construction will expand and twist when exposed to temperatures above 1000oF Correct Answer-Type II What part of Type III construction carries the interior load Correct Answer-Wood, masonry, unprotected steel What type of construction is less likely to collapse unless affected by a large volume of fire Correct AnswerType IV What is a reason to establish a collapse zone for a Type V structure Correct Answer-Interior Operations cannot be justified What BEST describes what the size of collapse zone must consider Correct Answer-The type of building construction and the safest location for apparatus What is a result of starting a generator while under load Correct Answer-Can damage the electrical system What can prevent overloading when testing lighting equipment Correct Answer-Connect each light to the generator one light at a time What uses of rescue tools includes tools that ensure vehicle and structural members will not move during rescue Correct Answer-Stabilizing Which rescue tool power source may be less powerful than the others Correct Answer-Electric Which rescue tool source is powered by compressed air cylinders Correct Answer-Pneumatic

 


Download Study Material

Buy This Study Material

$17.00
Buy Now
  • Immediate download after payment
  • Available in the pdf format
  • 100% satisfaction guarantee

Study Material Information

Category: exam bundles
Description:

FF2 Exam Prep (NATIONAL); Questions and Answers; IFSTA Essentials of Firefighting Exam Prep (For FF2) 2026/2027) (Complete and Verified) (28pages)

UNLOCK ACCESS $17.00