FREE AND STUDY GAMES ABOUT BACKFLOW
PREVENTION EXAM QUESTIONS
Actual Qs and Ans Expert-Verified Explanation
This Exam contains:
-Guarantee passing score -37 Questions and Answers -format set of multiple-choice -Expert-Verified Explanation
Question 1: Cross Connection Control
Answer:
*Containment *Isolation
Question 2: Disadvantages to Air Gaps
Answer:
*Splash *Downstream Water Pressure
Question 3: Air Gap
Answer:
complete physical separation between a free-flowing discharge of potable water and an open receiving vessel.
Question 4: Qualities of an Air Gap
Answer:
*Prevents against backpressure and back siphonage *Approved against all types of cross connection w/possibility of back pressure or back siphonage
Question 5: Back Siphonage
Answer:
*negative or reduced pressure in supply line *caused by a break in a water main, opening a fire hydrant or demands on a system higher than the design allows *creates potential for siphons to reverse water flow
Question 6: Types of Cross Connection
Answer:
*Direct Cross Connection *Indirect Cross Conneciton
Question 7: Air Gap Testing
Answer:
Make sure the air gap has appropriate clearance
Question 8: Categories of hazard
Answer:
*Pollutant *Contaminant
Question 9: Types of Containment
Answer:
*High Hazard *High Health Hazard *Toxic *Contamination Hazard
Question 10: Back Pressure
Answer:
*pressure higher than the supply pressure *caused by a pump, elevated tank, boiler, air/steam pressure, etc
Question 11: Qualities of Atmospheric Vacuum Breaker
Answer:
*Water flow causes air inlet valve to close air inlet port *When water flow stops, the air inlet valve falls and protects against back siphonage *Prevent against Back Siphonage, Indirect Cross Connection only and toxic/non-toxic hazard
Question 12: Examples of Air Gap
Answer:
*Lavatory *Sink *Bathtub
Question 13: Backflow
Answer:
undesirable reversal of flow in a potable water system
Question 14: When is water considered Used?
Answer:
Once it passes through the water meter and considered sold. The water quality can no longer be guaranteed
Question 15: Flood Level Rim
Answer:
the height at which water will flow out of the receiving vessel if the drain and/or overflow is not functioning
Question 16: Qualities of Spill Resistant Vacuum Breaker
Answer:
*Water flows, valve opens, air inlet closes
- Water stops, valve closes, air inlet opens
*Must contain resiliently sealed test cocks & shut off valves at each end *Prevents against Back Siphonage, Indirect cross connection & toxic/non-toxic hazards
Question 17: Spill Resistant Vacuum Breaker Installation Requirements
Answer:
*Minimum 12-inch clearance above the highest head, pipe, fittings, fixtures, valves, etc.*Valves can be installed on the downstream side and may be under constant pressure
Question 18: Qualities of Pressure Vacuum Breaker
Answer:
*check valve opens when water flows *air inlet valve opens when water stops *must contain resiliently sealed test cocks & shutoff valves at each end *Prevent against Back Siphonage only, Indirect cross connection only & toxic/non-toxic hazards
Question 19: Direct Cross Connection
Answer:
Supports both backpressure and back siphonage
Question 20: Atmospheric Vacuum Breaker Installation Requirements
Answer:
*Minimum of 6 inch clearance above highest head, pipe, fittings, fixtures, ect.*Can NOT be installed with valves on the downstream side
- MUST be installed AFTER any valves
*Shall not be under pressure for more than 12 hours in any 24 hour period
Question 21: Inspections for Pressure Vacuum Breaker
Answer:
Should be completed:
*On installation -AND- *As often as required by local jurisdiction
Question 22: Downstream Water Pressure
Answer:
if desired with Air Gap, following equipment may be required:
*Reservoir *Pumps *Storage Tanks *And/or Other Equipment
Question 23: Indirect Cross Connection
Answer:
Supports only back siphonage
Question 24: Pollutant
Answer:
the least of the hazards and does not create a health hazard but lowers the aesthetic quality of the water