PDF Download
FREE AND STUDY GAMES ABOUT BACKFLOW TEST
Actual Qs and Ans Expert-Verified Explanation
This Exam contains:
-Guarantee passing score -52 Questions and Answers -format set of multiple-choice -Expert-Verified Explanation Question 1: In accordance with tile 17 maximum clearance above grade for an RP is:
- 36 in
- 42 in
- 12 in
- 24 in
Answer:
- 36 inches
- Awrobic bacteria monitoring
- Cross connection surveys
- Plumbing code compliance
- State compliance schedules
Question 2: The US EPAs total coliform rule contains requirements for:
Answer:
- Plumbing code compliance
Question 3: A fire sprinkler system containing black iron pipe should be protected with a minimum of
- double check
- atmospheric vacuum breaker
- air gap
- pressure vacuum breaker
Answer:
- Double check
- Containment back pressure
- Containment back siphonage
- Isolation back pressure
- Isolation back siphonage
Question 4: A spill resistant vacuum breaker is protection for:
Answer:
- Isolation back siphonage
- When water stops running out of the number 2 test cock
- When there is a slight drip at test cock number 2
- When the gauge drops a
Question 5: When compensating for a leaky number one shut off valve on a PVB, how do you know you have reach proper compensation?
Answer:
- When there is a slight drop at test cock number 2
Question 6: When testing check valve number one of a double check if the water continues to
flow out of the test cock number three and most probable cause is:
- Lincoln number to Check
- Number two shut off
- number two check valve leak
- number one
valve leak
Answer:
- Number one shut off valve leak
- the relief valve spring
- the number to check valve
- closing the number to shut off
- the spring on the number one check valve
Question 7: Design pressure of an RP is created by:
Answer:
- The spring on the number one check valve
Question 8: Well testing SVP the check valve water continues to run from the bleed screw which
of the following is true:
- Number two line valve is leaking
- number one line valve is leaking
- check valve is leaking
- who in the world knows
Answer:
- Number one line valve is leaking
- Maintain water pressure in the down stream piping
- Prevent backpressure during thentesting of the assembly
Question 9: When testinf a backflow, the number 2 shutoff must be closed first to:
- Prevent Backsiphonage during the testing of the assembly
- Prevent
Answer:
- Prevent back siphonage during the testing of the assembly
- Air admittance valve opens
- Check valve closes
- Check valve opens
- Downstream uses open
Question 10: A characteristic of the SVP operation is that the air inlet must seal before the:
Answer:
- Check valve opens
- Approved
- Inline testable
- Repairable
- Replaceable
Question 11: A dual check valve is not:
Answer:
- Inline testable
Question 12: In accordance with title 17, backflow testerd must demonstrate compency in
testing to:
- Local health department
- Water supplier or health agency
- American Backflow Prevention Association
- University of California