FREE AND STUDY GAMES ABOUT CH 25 DIGITAL RAD
EXAM QUESTIONS
Actual Qs and Ans Expert-Verified Explanation
This Exam contains:
-Guarantee passing score -108 Questions and Answers -format set of multiple-choice -Expert-Verified Explanation Question 1: The appropriate anatomical menu is selected by the body part by the _ when the imaging plate is loaded into the reading unit.
Answer:
Radiographer Question 2: grounds the plate to eliminate electrostatic problems and absorb light to increase sharpness
Answer:
conductor layer
Question 3: The most common phosphor with characteristics favorable for CR is
Answer:
barium flurohalide bromide, iodides with europium activators
Question 4: Which system uses a photostimulable storage phosphor imaging plate
Answer:
cassette base
Question 5: The Fuji computed radiography (CR) system uses an S number to assist in evaluating exposure and are
Answer:
INVERSELY PROPORTIONAL
Question 6: It is critical to adhere to uniform positioning and collimation procedures when using a CR system.
Answer:
T
Question 7: Over exposure in digital yields good images with unnecessary but
Answer:
high dose to the patient.Question 8: This electrical signal is, in turn, converted to a unique digital value for that particular level of
Answer:
luminescence
Question 9: The latent image will lose about ___ % of its energy in __hrs
Answer:
25,8 Question 10: T/F There are certain expectations that need to be met when placing more than one image per plate.
Answer:
T
Question 11: The imaging plate is scanned by a___ laser beam
Answer:
helium-neon Question 12: What does not release all the energy absorbed from the incident x-ray beam
Answer:
Fluorohalides luminesce
Question 13: The___ and ____ of an imaging plate can occur in a single processor unit
Answer:
reading, erasing
Question 14: After reading the imaging plate the electrons to return to a
Answer:
lower energy state Question 15: The imaging plate is more sensitive to scatter both__ and___it is sensitized through exposure to the x-ray beam.
Answer:
before and after
Question 16: what begins with an x-ray exposure to the imaging plate.
Answer:
Image acquisition Question 17: prevents light from erasing data on the imaging plate or leaking through the backing
Answer:
light shield layer and backing layer Question 18: Digital Radiography can be divided into two groups:
Answer:
Computed Radiography (CR) Cassette-based (indirect digital) Direct Digital Radiography (DR) Cassette-less (direct digital)
Question 19: Image acquisition begins with x-ray exposure to the
Answer:
imaging plate
Question 20: Failure to use a high enough___ setting produces quantum mottle
Answer:
MAS
Question 21: T/F A cassette base system can be used in a bucky or for portables
Answer:
True
Question 22: Factors that produce low contrast include
Answer:
High KVP No grid or inadequate grid efficiency Inadequate beam limitation (i.e., collimation) Increased part size or tissue thickness
Question 23: The photostimulable phosphor imaging plates layers include
Answer:
protective layer, phosphor layer,support layer, conductor layer, light shield layer,backing layer Question 24: The imaging plate phosphor will absorb more___ than the rare-earth phosphor and film,
Answer:
low-energy scatter Question 25: Kilovoltage for computed radiography will control____ similar to film radiography
Answer:
contrast Question 26: A good scintillator yields many light photons for each incoming x-ray photon; __ to __ visible photons out per 1kV of incoming x-ray energy are typical.
Answer:
20,50