FREE AND STUDY GAMES ABOUT CODEOLOGY 3 EXAM

Class notes Jan 11, 2026
Preview Mode - Purchase to view full document
Loading...

Loading study material viewer...

Page 0 of 0

Document Text

PDF Download

FREE AND STUDY GAMES ABOUT CODEOLOGY 3 EXAM

QUESTIONS

Actual Qs and Ans Expert-Verified Explanation

This Exam contains:

-Guarantee passing score -23 Questions and Answers -format set of multiple-choice -Expert-Verified Explanation Question 1: If a branch-circuit fuse is not marked with an interrupting rating, then the interrupting rating for that fuse is ? .

Answer:

10,000A

NEC Ref: 240.6

Question 2: All circuit breaker are required to have their ampere ratings marked on the circuit breaker handle or escutcheon

Answer:

False

Note: See 240.83(B) and 240.83(A).

Question 3: A fuse or circuit breaker with a 600-volt AC rating is permitted to be used on 300-volt DC application by the half voltage rule in NEC Article 240.

Answer:

False Note: for DC applications, a fuse or circuit breaker should be marked with a DC voltage rating equal or greater than the system DC voltage.

Question 4: Generally, conductors shall be protected at their ampacities by branch-circuit overcurrent devices

Answer:

True 240.4 there can be other requirements and permissions. See 240.4(A) through (G) Question 5: When a fuse or circuit breaker interrupts a short-circuit current exceeding its interrupting rating, the UL product standards require that an indication pin on the fuse or circuit breaker actuate so that the Electrical Worker knows to replace the device w

Answer:

false Review the still photos from Figure 11 and the associated videos available.Question 6: As generally required in the NEC, match the overcurrent device ampere rating for the following small conductor sizes.

Answer:

10 AWG Aluminum ? 25 amperes, 12 AWG Aluminum ? 15 amperes, 10 AWG Copper ? 30 amperes, 12 AWG Copper ? 20 amperes, 16 AWG Copper ? 10 amperes, 18 AWG Copper ? 7 amperes Question 7: Interrupting ratings are required to be marked on supplemental protective devices

Answer:

False

NEC ref: 240.60(C)

Question 8: The highest current at rated voltage that a device is identified to interrupt under standard test conditions describes ? .

Answer:

  • interrupting rating
  • NEC Reference 100 Question 9: Per the second paragraph of 110.9, devices such as motor starters and switches must have interrupting ratings at applied voltage sufficient for the available short circuit at its line terminals.

Answer:

False

Question 10: Ampere rating, voltage rating, interrupting rating where other than 10,000 amperes, current limiting where applicable, and the name or trademark of the manufacturer are all items which must be plainly marked on the barrel of a fuse.

Answer:

True The corzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzzrect

answer is: 240.60(C)

Question 11: Straight voltage rated circuit breakers of the proper voltage rating (the volt rating is greater than system line-line voltage) are allowed to be used on which of the following voltage systems?

Answer:

  • 120 V 1 Ø, 2 W, solidly grounded
  • II. 120/240 V 1 Ø, 3 W, solidly grounded III. 208 Y/120 V 3 Ø, 4 W, solidly grounded IV. 240 V 3 Ø, 3 W, ungrounded or corner grounded delta

  • 480 Y/277 V 3 Ø, 4 W, solidly grounded
  • VI. 480 V 3 Ø, 3 W, ungrounde Question 12: If a conductor's ampacity does not correspond to a standard circuit breaker or fuse ampere rating found in _1_, __2__ permits selecting the next standard ampere rating if specific conditions in __3___ are met.

Answer:

1) 240.6 2)240.4(B)

3) 240.4(B)

Question 13: Fuses have straight and slash voltage ratings.

Answer:

False Note: By their design, fuses are full voltage rated devices. Slash voltage ratings are not an issue. For example, Class J fuses are rated at 600 V AC and are utilized on systems rated 600 V AC on any distribution system.Question 14: Slash voltage rated circuit breakers of the proper voltage rating are allowed to be used on which of the following voltage systems?

Answer:

  • 120 V 1 Ø, 2 W, solidly grounded
  • II. 120/240 V 1 Ø, 3 W, solidly grounded III. 208 Y/120 V 3 Ø, 4 W, solidly grounded

IV. 240 V 3 Ø, 3 W, ungrounded or corner grounded delta

V. 347 V

VI. 480 Y/277 V 3 Ø, 4 W, solidly grounded

VII. 480 V 3 Ø, 3 W,

Question 15: If a branch-circuit circuit breaker is not marked with an interrupting rating, then the interrupting rating for that circuit breaker is ? .

Answer:

5,000 240.83(c) Question 16: The voltage of an electrical system must be equal to or greater than voltage rating of an OCPD.

Answer:

False Question 17: New service equipment in commercial buildings must be field marked with the maximum available fault current and the date the calculations were performed.

Answer:

True Question 18: Typically what is the single most influencing factor on the magnitude of the available short-circuit current at the service?

Answer:

Transformer supplying the service Question 19: A panelboard that is located downstream from a service disconnect is calculated to have 45,000 amperes of available fault current. A circuit breaker installed in this downstream panel must have an interrupting rating equal or greater than ? .

Answer:

45,000 A Correct Lesson 3 introduces interrupting rating. This question assumes using fully rated circuit breakers. Series rating is covered later. If the circuit breaker in the downstream panelboard were part of a series rating of at least 45 kA, then t

Download Study Material

Buy This Study Material

$11.99
Buy Now
  • Immediate download after payment
  • Available in the pdf format
  • 100% satisfaction guarantee

Study Material Information

Category: Class notes
Description:

PDF Download FREE AND STUDY GAMES ABOUT CODEOLOGY 3 EXAM QUESTIONS Actual Qs and Ans Expert-Verified Explanation This Exam contains: -Guarantee passing score -23 Questions and Answers -format set o...

UNLOCK ACCESS $11.99