PDF Download
FREE AND STUDY GAMES ABOUT EPA TESTS EXAM
QUESTIONS
Actual Qs and Ans Expert-Verified Explanation
This Exam contains:
-Guarantee passing score -100 Questions and Answers -format set of multiple-choice -Expert-Verified Explanation
Question 1: Which refrigerants is a HCFCs?
Answer:
R-123 and R-22 Question 2: Refrigerant cylinders should be shipped:
Answer:
In the vertical upright position Question 3: A condition of excessive superheat at the evaporator outlet and compressor inlet of an air conditioning system could be an indication of
Answer:
Low on refrigerant charge
Question 4: Which of the following refrigerants can be mixed?
Answer:
None of refrigerants can be mixed
Question 5: Comfort cooling chillers and all other equipment with an annual leak rate of ____%
requires repair under EPA regulations:
Answer:
15 Question 6: One of the easiest ways to identify the type of refrigerant in a system is to:
Answer:
Check the name plate data Question 7: R-123 is classified as a ____ under ASHRAE 34 standard safety group:
Answer:
B1 Question 8: The sale of class I and Class II refrigerants have been restricted to technicians
certified by an EPA approved program since:
Answer:
November 14, 1993 Question 9: The maximum pressure that should be applied to a low pressure chiller when leak
checking with controlled nitrogen is:
Answer:
10 psig Question 10: The condition and state of the refrigeration leaving a receiver is:
Answer:
Subcooled liquid Question 11: CFCs have been manufactured in the United States since:
Answer:
1995
Question 12: Which refrigerants contain the most chlorine
Answer:
CFCs
Question 13: The time it takes to properly evacuate and dehydrate a system prior to charging
with refrigerant is determined by the:
Answer:
1) Total volume of the system 2) Amount on non-condesibles (moisture) in the system 3) Ambient temperature Question 14: Traces of oil around the sight glass inlet fitting of a refrigeration system might be the indication of
Answer:
A leak Question 15: Front seating the three-way suction service valve close the:
Answer:
Suction inlet to the valve Question 16: A low pressure chiller providing comfort cooling that has an annual leak rate of
____% of the total charge must be repaired:
Answer:
15
Question 17: Which refrigerant have a "0" ODP?
Answer:
HFCs Question 18: Stratospheric ozone depletion is a ______ problem:
Answer:
Global Question 19: A low pressure chiller generally has the rupture disk set at:
Answer:
15 psig
Question 20: The required level of evacuation for recovery equipment manufactured after November 15, 1993, on a system containing less than 200 pounds of R-22 refrigerant is:
Answer:
- inches Hg
Question 21: Which refrigerant is a CFCs?
Answer:
R-12 Question 22: R-134a is "drop-in" refrigerant for:
Answer:
R-134a in not a drop-in refrigerant Question 23: Recovery machines using water as the condensing medium would generally use
the:
Answer:
Municipal water supply Question 24: Type II classification, as identified by EPA, applies to what equipment?
Answer:
Split air conditioning equipment with five (5) pounds of refrigerant and greater Question 25: Recovery time can be shortened by:
Answer:
1) Recovering as much liquid as possible in the initial stages 2) Using short hoses 3) Cooling the recovery tank in ice water Question 26: A major repair is defined by EPA, as replacing the:
Answer:
1) Compressor 2) Evaporator