FREE AND STUDY GAMES ABOUT NEW S12 EXAM

QUESTIONS

Actual Qs and Ans Expert-Verified Explanation

This Exam contains:

-Guarantee passing score -42 Questions and Answers -format set of multiple-choice -Expert-Verified Explanation Question 1: What color tag shall be placed at the control valves if a standpipe system is found to have a non-critical deficiency?

Answer:

yellow

Question 2: What type of buildings are required to have a standpipe system?

Answer:

buildings greater than 75' in height Question 3: If a building has a sprinkler system that contains 400 sprinkler heads, how many spare sprinkler heads must be kept on the premises?

Answer:

12 Question 4: In a foam extinguishing system, what color should the caps on the Fire Department Foam Connection be painted?

Answer:

red with an orange band

Question 5: A pump that is used when the water pressure available at the highest sprinkler head does not meet the demands of the sprinkler system is known as a _____.

Answer:

booster pump Question 6: If your building is 150,000 square feet and the standpipe is out of service; How many fire guards are needed to patrol the building until the system is restored?

Answer:

3 Question 7: The Automatic Ball Drip device on a standpipe system should be installed in the ______ position.

Answer:

horizontal Question 8: On a sprinkler system, when are the circuit breakers or fuses maintained on a fire pump with a diesel engine system? (Refer to your Reference Guide)

Answer:

semiannually Question 9: How often should a standpipe system be subjected to a hydrostatic test?

Answer:

  • years
  • Question 10: The Impairment coordinator must make certain notifications in the event of an

impairment. All of the following must be notified except:

Answer:

Local Fire house Question 11: Automatic fill pumps supply water to most gravity tanks. The pumps shall fill the tank at a minimum rate of _____ gallons per minute.

Answer:

65 gpm

Question 12: The vertical supply pipes in a sprinkler system are known as _____.

Answer:

risers Question 13: A sprinkler head that has a temperature classification of "high" (250 to 300 degrees) will have a glass bulb of what color?

Answer:

Blue Question 14: What class of standpipe system is designed to be used by civilians and firefighters?

Answer:

Class 1 Question 15: If a building is equipped with a hose rack, what is the maximum length of a single hose line?

Answer:

125 feet Question 16: Where should a "Riser Card" (an approved card bearing the dates of each inspection, certificate of fitness number, and the signature of the certificate of fitness holder) be placed?

Answer:

near the main water supply control valve Question 17: What will occur when a high velocity flow of water is abruptly shut off?

Answer:

a water hammer Question 18: What is the maximum distance from the bottom of a gravity tank to the top floor hose outlet?

Answer:

25 feet

Question 19: For a standpipe system, when are the water level alarms tested on a water storage tank? (Refer to your reference guide)

Answer:

semiannually Question 20: Post Indicator Valves (PIV's), if present, shall be sealed in the ________position.

Answer:

open

Question 21: Which of the following is not a component of a sprinkler head?

Answer:

impeller Question 22: Which of the following types of standpipe systems must have an accompanying sign which will read "Dry Standpipe for Fire Department use only"?

Answer:

a dry standpipe with no automatic water supply Question 23: A working area of not less than _____ inches wide shall be provided and maintained in front of and around all Fire Department Connections (FDC's).

Answer:

36 inches Question 24: On a standpipe system, when are the circuit breakers and fuses inspected on a fire pump with a diesel engine system? (refer to the reference guide)

Answer:

monthly

Question 25: Select the incorrect statement regarding sprinkler heads.

Answer:

Hard deposits can be removed from a sprinkler head using warm soap and water Question 26: How frequently are control valve tamper switches tested on a sprinkler system?(refer to your reference guide)

Answer:

semiannually

Download Study Material