Question 1: What means the process of recording?
Answer:
Graphy
Question 2: What is the placement of lead 2
Answer:
Right arm left leg
Question 3: What artifact presents small spikes?
Answer:
AC Interference
Question 4: Max volume of air remaining in the lungs after exhale
Answer:
Residual Volume (RV)
Question 5: What instructions do you give for exercise stress test
Answer:
The patient should wear clothes and shoes for exercising. - The provider will indicate what daily medications should be taken prior to the test. - The patient should not take a dose of Viagra, Cialis, or Levitra for erectile dysfunction 48 hours before
Question 6: This arrhythmia occurs when the ventricles quiver uncontrollably
Answer:
Ventricular Fibrillation
Question 7: What are augmented leads
Answer:
Augmented leads also provide information on the vertical (frontal) plane of the heart. These unipolar leads are augmented or increased in size on the tracing. Augmented leads use the right arm (RA), left arm (LA), and left leg (LL) electrodes.Question 8: What electrode is placed on the fourth intercostal space at the right sternal edge
Answer:
Chest V1 (red)
Question 9: How many times should the spirometer test be repeated
Answer:
- times
Question 10: This monitor is worn over the heart for 24/48 hours.
Answer:
Holter monitor
Question 11: What is a default gain or sensitivity
Answer:
10 mm/mV
Question 12: artifact appears as jagged peaks with irregular height and spacing
Answer:
Somatic Tremor
Question 13: Fifth intercostal space midclavicular line
Answer:
Chest V4 (blue) Question 14: What is a recording or record of the electrical impulses of the heart produced by an electrocardiograph
Answer:
ecg
Question 15: Procedure using a metered dose inhaler
Answer:
Place one to two inches from mouth breathe in Hold your breath for 10 seconds (or count to 10) and then breathe out.
Question 16: Pt is getting a 12 lead ECG how many electrodes is placed on pt?
Answer:
10 Question 17: Patient is getting nebulizer treatment what position should they be in
Answer:
Sitting up right Question 18: Type of artifact that is upward and downward movement of wave form where isoelectric lines shift locations
Answer:
Wandering baseline
Question 19: What means the process of measurement?
Answer:
-metry
Question 20: There is an artifact on leads 2 and 3 which lead would you check
Answer:
Left leg
Question 21: Artifact occurs when electrons are old with poor skin preparation
Answer:
Wandering Baseline
Question 22: What state are the cardiac cells resting
Answer:
polarized Question 23: This test allows patient to record ecg when symptoms occur for up to 30 days
Answer:
Cardiac Event Recorder
Question 24: What are precordial leads
Answer:
unipolar leads. Each is a positive pole. provide information on the horizontal (front to back) plane of the heart. The six precordial leads are labeled V1, V2, V3, V4, V5, and V6
Question 25: Ultrasonic waves directed through the heart?
Answer:
Echo
Question 26: What are standard leads?
Answer:
The bipolar (standard) leads are named leads I, II, and III. They use the arm electrodes and the left leg electrode to create pictures of the vertical (or frontal) plane of the heart.Question 27: This test determines how effectively gas travels from the lungs to the bloodstream
Answer:
Lung diffusion capacity