-Guarantee passing score -35 Questions and Answers -format set of multiple-choice -Expert-Verified Explanation Question 1: Solutions should have been changed in the processor 1 week ago. Continuing to use exhausted developer will result in ____ films.
Answer:
light Question 2: Digital radiography requires less radiation than traditional radiography because the
Answer:
sensor is more sensitive to x-ray energy.Question 3: The charge-coupled device (CCD) in direct digital imaging sensors is made of
Answer:
silicon.
Question 4: Fixer cutoff will result in a _____ border.
Answer:
straight black
Question 5: The device that intensifies or increases the effect of the radiation and decreases the amount of exposure time needed when exposing an extraoral radiograph is a(n)
Answer:
intensifying screen.
Question 6: The correct order of steps in manual film processing is
Answer:
develop, rinse, fix, wash.Question 7: The silver halide crystals are located within which of the following layers of the radiographic film?
Answer:
Gelatin that suspends the emulsion Question 8: Which of the following is an extraoral film that is placed outside the mouth during dental x-ray exposure procedures?
Answer:
Cephalometric Question 9: The recommended distance between the safelight and where the films are unwrapped is
Answer:
- feet.
Question 10: Green-sensitive extraoral film is used with cassettes that have which type of intensifying screen?
Answer:
Rare earth Question 11: All the following are true statements about digitizing film-based radiographic images except
Answer:
it duplicates in the same detail as the original film.
Question 12: When loading an extraoral film into the cassette prior to exposure, the
Answer:
procedure must be done in the darkroom.
Question 13: When film emulsion interacts with x-rays, the result is
Answer:
a latent image.
Question 14: Positioning instruments in digital radiography
Answer:
assist in film placement and keep the patient's fingers from being exposed.Question 15: F-speed dental x-ray film reduces radiation exposure to the patient by __% compared with D-speed dental x-ray film.
Answer:
60
Question 16: ____ hardens the film emulsion during film processing.
Answer:
Fixing
Question 17: The safest place to store unopened boxes of dental film is in the
Answer:
darkroom.
Question 18: The ideal time and temperature for manual developing is
Answer:
- minutes at 68° F.
Question 19: Clear spots on a processed film can be caused by
Answer:
fixer contacts film prior to processing.
Question 20: A plastic or metal film cassette holds and protects the extraoral film. During exposure, the side of the cassette the must face the patient is the _____ side.
Answer:
front Question 21: Which of the following time and temperature errors will result in reticulation of the film emulsion?
Answer:
Sudden temperature change between developer and water bath Question 22: Faster film speed would be associated with _____ silver halide crystals, a _______ emulsion, and presence of special radiosensitive dyes.
Answer:
smaller; thinner Question 23: All of following are true statements about storage plates used with phosphor storage plate (PSP) imaging systems except that
Answer:
they utilize radio frequency transmission to transmit the image to the computer via radio waves.Question 24: When developer solution in an automatic processor is warmer than 83° F, the processed film will appear
Answer:
dark or black.
Question 25: The life of the processing solutions is affected by
Answer:
the number of films processed.the time elapsed since last change.the size of films processed.
Question 26: One reason for a lighter than normal radiograph is the
Answer:
developer solution is too weak.