  • What is the primary purpose of a fire alarm system?
  • To prevent fires from occurring
  • To alert occupants of a fire **
  • To extinguish fires automatically
  • To inspect electrical wiring

Rationale: The primary function of a fire alarm system is to alert

occupants to evacuate during a fire.

  • Which type of fire detector responds to heat rather than smoke?
  • Ionization smoke detector
  • Photoelectric smoke detector
  • Heat detector **
  • Carbon monoxide detector

Rationale: Heat detectors activate when a certain temperature or

rate of rise is reached, unlike smoke detectors.

  • What NFPA standard governs the installation of fire alarm systems?

A. NFPA 13

B. NFPA 72 **

C. NFPA 101

D. NFPA 70

Rationale: NFPA 72 is the National Fire Alarm and Signaling Code,

which outlines installation and maintenance standards.

  • What is the minimum audible sound level required for a fire alarm in
  • sleeping areas?

  • 60 dB
  • 65 dB
  • 75 dB **
  • 85 dB

Rationale: NFPA 72 specifies a minimum of 75 dB at the pillow level

in sleeping areas to ensure occupants are awakened.

  • Which component of a fire alarm system receives signals from
  • detectors and initiates notification?

  • Initiating device
  • Control panel **
  • Notification appliance
  • Circuit breaker

Rationale: The control panel monitors devices and activates alarms

when signals are received.

  • What is the purpose of a manual pull station?
  • To detect smoke automatically
  • To allow occupants to manually initiate the fire alarm **
  • To notify the fire department only
  • To test the fire alarm system

Rationale: Manual pull stations provide a means for occupants to

trigger the alarm if they discover a fire.

  • Which type of fire detector is most responsive to smoldering fires?
  • Ionization detector
  • Photoelectric detector **
  • Heat detector
  • Flame detector

Rationale: Photoelectric detectors are better at detecting slow,

smoldering fires because they sense visible smoke particles.

  • What is the purpose of a NAC (Notification Appliance Circuit)?
  • To provide power to the control panel
  • To activate notification devices like horns and strobes **
  • To communicate with the fire department
  • To monitor smoke detectors

Rationale: NACs deliver power from the control panel to audible and

visual notification appliances.

  • Which type of fire alarm system is designed for a single building and is
  • self-contained?

  • Addressable system
  • Conventional system **
  • Central station system
  • Remote station system

Rationale: Conventional systems divide the building into zones, each

wired to a control panel.

  • What is the advantage of an addressable fire alarm system?
  • Lower installation cost
  • Each device has a unique address for precise location identification
  • **

  • No maintenance required
  • Uses less wiring than a conventional system

Rationale: Addressable systems allow precise identification of which

detector or device has activated.

  • How often should fire alarm systems be tested according to

NFPA 72?

  • Monthly for all devices
  • Weekly for control panels only
  • Annually for all devices **
  • Every 5 years