TCFP INSPECTOR'S CLASS QUESTIONS QUESTIONS AND ANSWERS (2026/2027)
(VERIFIED ANSWERS)
1) Manual fire alarm boxes shall be located not more than ___ feet from the entrance to each exit.
Â
 5
 10
 15
 20 Â
 25
Â
 Feedback
907.5.2.1
Unanswered
86% got this correct
2) Horizontal and vertical sliding and rolling fire doors shall be inspected and tested __________ to confirm proper operation and full closure.
Â
 Every 30 days
 Every 90 days
 Every 36 months
 Every 72 months
 Annually
Â
 Feedback
703.4
Unanswered
62% got this correct
3) Combustible trim, excluding handrails and guardrails, shall not exceed ___ percent of the specific wall or ceiling areas to which it is attached.
Â
 10
 15
 20
 25
Â
 Feedback
804.1
Unanswered
86% got this correct
4) Candles and open flames are allowed to be used on or near decorative vegetation while immediately supervised.
Â
 T
 F
Â
 Feedback
806.4
Unanswered
92% got this correct
5) Swinging fire doors shall close from the _________ position and latch automatically.
Â
 Partially open
 Partially closed
 Full open
Â
 Feedback
703.2.3
Unanswered
67% got this correct
6) Combustible material shall not be stored in ________________.Â
(check all that apply)
Â
 Boiler rooms (Missed)
 Mechanical rooms (Missed)
 Lunch break rooms
 Electrical equipment rooms (Missed)
 Underground rooms
Â
 Feedback
315.2.3
Unanswered
74% got this correct
7) Temporary wiring for electrical power and lighting installations is allowed for a period not to exceed ___ days.
Â
 30
 60
 90
 180
Â
 Feedback
605.9
Unanswered
65% got this correct
8) A permit is required to install stationary storage battery systems having a liquid capacity of more than ____ gallons.
Â
 25
 50
 75
 100
Â
 Feedback
105.7.2
Unanswered
66% got this correct
9) An operational permit is required to use a building or portion thereof as a high-piled storage area exceeding _____ square feet.
Â
 300
 400
 500
 600
Â
 Feedback
105.6.22
Unanswered
72% got this correct
Â
10) Covered mall buildings exceeding __________ square feet shall be provided with standby power systems that are capable of operating the emergency voice/alarm communication.
Â
 25500
 40000
 50000
 75000
Unanswered
89% got this correct
11) Manual fire alarm boxes may be any color, approved by the fire code official, that contrasts the color of the location in which they are installed.
Â
 T
 F
Â
 Feedback
907.5.2.3
Unanswered
59% got this correct
12) Outside storage of combustible materials shall not be located within ___ feet of a property line.
Â
 5
 10
 15
 20
Â
 Feedback
315.3
Unanswered
64% got this correct
13) Classify the following based on occupancy:Â Funeral parlor
Â
 A-1
 A-2
 A-3
 A-4
 A-5
Â
 Feedback
Ch. 2
Unanswered
51% got this correct
14) Classify the following based on occupancy:Â Child care facilities that provide supervision and personal care on less than a 24 hour basis for more than 5 children 2 1/2 years of age or less.
Â
 E
 I-2
 B
 I-4
Â
 Feedback
pg. 26
Unanswered
77% got this correct
15) Extension cords and flexible cords shall not be a substitute for ______________.
Â
Â
 Possible correct answers: Â
permanent wiring
Â
 Feedback
605.5
Unanswered
56% got this correct
16) Combustible storage shall be kept a minimum of ___ feet from battery chargers.
Â
 3
 5
 10
 15
Â
 Feedback
309.2
Unanswered
61% got this correct
17) Classify the following based on occupancy:Â Hotels (transient)
Â
 R-1
 R-2
 R-3
 R-4
Â
 Feedback
pg. 26
Unanswered
60% got this correct
18) An operational permit is required for the storage and handling of combustible fibers in quantities greater than __________.
Â
 100 cubic feet
 100 square feet
 200 cubic feet
 200 square feet
Â
 Feedback
105.6.7
Unanswered
81% got this correct
19) Commercial cooking systems for low-volume cooking operations such as places of worship, seasonal businesses and senior centers shall be inspected ________.
Â
 Every month
 Every 3 months
 Every 6 months
 Every 12 months
Â
 Feedback
Table 609.3.3.1
Unanswered
67% got this correct
20) The maximum travel distance to a fire extinguisher in a Class A, extra (high) hazard occupancy is ___ feet.
Â
 30
 50
 75
 100
Â
 Feedback
Table 906.3 (1)
Unanswered
83% got this correct
21) The minimum corridor width shall be not less than 44 inches.
Â
 T
 F
Â
 Feedback
1018.2
Unanswered
72% got this correct
22) Artwork and teaching materials shall be limited on walls of corridors to not more than ___ percent of the wall area.
Â
 15
 20
 25
 30
Â
 Feedback
807.4.4.2
Unanswered
56% got this correct
23) A manual actuation device shall be located at or near a means of egress from the cooking area a minimum of ___ feet and a maximum of ___ feet from the kitchen exhaust system.
Â
 5, 10
 10, 15
 10, 20
 15, 20
 15, 25
Â
 Feedback
904.11.1
Unanswered
64% got this correct
24) An operational permit is not required to melt, cast, heat treat or grind less than 10 pounds of magnesium.
Â
 T
 F
Â
 Feedback
105.6.28 read carefully
Unanswered
65% got this correct
25) Stairways shall have a minimum headroom clearance of ___ inches measured vertically from a line connecting the edge of the nosings.
Â
 78
 80
 82
 84
Â
 Feedback
1009.2
Unanswered
76% got this correct
Â
26) Where there is a conflict between a general requirement and a specific requirement, the __________Â shall be applicable.
Â
 General requirement
 Specific requirement
 Most stringent
 Least stringent
Unanswered
57% got this correct
27) Hand-held portable fire extinguishers having a gross weight not exceeding ___ pounds shall be installed so that their tops are not more than ___ feet above the floor.
Â
 40, 3
 40, 5
 40, 3.5
 40, 5.5
Â
 Feedback
906.9.1
Unanswered
93% got this correct
28) Fire alarm, sprinkler and standpipe systems shall be maintained in an operable condition at all times in vacant premises.
Â
 T
 F
Â
 Feedback
311.2.2
Unanswered
79% got this correct
29) The first emergency evacuation drill of each school year shall be conducted within _____ days of the beginning of classes.
Â
 10
 14
 21
 28
Â
 Feedback
408.3.1
Unanswered
63% got this correct
30) An operational permit is required for the storage, use, or handling at NTP of _____ of compressed corrosive gas.
Â
 200 cubic feet
 504 cubic feet
 6000 cubic feet
 Any amount
Â
 Feedback
Table 105.6.8
Unanswered
63% got this correct
31) The height of manual fire alarm boxes shall be a minimum of ___ inches and a maximum of ___ inches measured vertically, from the floor level to the activating handle or lever of the box.
Â
 36, 42
 36, 48
 42, 48
 44, 48
Â
 Feedback
907.5.2.2
Unanswered
67% got this correct
32) The minimum required distance from a structure for open burning shall not be less than ___ feet where the pile size is ___ feet or less in diameter and ___ feet or less in height.
Â
 50, 3, 2
 50, 2, 3
 25, 3, 2
 25, 2, 3
Â
 Feedback
307.4 ex. 2
Unanswered
56% got this correct
33) Bulk storage of tires is defined as storage of tires where the area available for storage exceeds _________ cubic feet.
Â
 5000
 10000
 15500
 20000
Â
 Feedback
902
Unanswered
52% got this correct
34) Portable outdoor fireplaces shall not be operated within ___ feet of a structure or combustible material.
Â
 5
 10
 15
 20
Â
 Feedback
307.4.3
Unanswered
58% got this correct
35) Permit amounts for cryogenic fluids are found in which table?
Â
Â
 Possible correct answers: Â
105.6.10, table 105.6.10, Table 105.6.10
Â
 Feedback
pg. 7
Unanswered
66% got this correct
36) Vehicle impact protection guard posts shall be set with the top of the posts not less than ___ feet above the ground.
Â
 3
 3.5
 4
 4.5
Â
 Feedback
312.2 (4)
Unanswered
67% got this correct
37) Where connected to a fuel-oil piping system, the maximum amount of fuel oil storage allowed outside above ground without additional protection shall be _____ gallons.
Â
 50
 200
 350
 660
Â
 Feedback
603.3.1
Unanswered
80% got this correct
38) Fire apparatus access roads shall have an unobstructed width of not less than ___ feet and an unobstructed vertical clearance of not less than ___ feet ___ inches.
Â
 20, 10, 6
 20, 13, 6
 22, 12, 8
 22, 14, 10
Â
 Feedback
503.2.1
Unanswered
72% got this correct
Â
39) Classify the following based on occupancy:Â Sales room
Â
 B
 A-3
 M
 S-2
Unanswered
56% got this correct
40) Turnstiles more than ___ inches high shall meet the requirements for revolving doors.
Â
 30
 36
 39
 42
Â
 Feedback
1008.3.1
Unanswered
46% got this correct
41) Extension cords shall be plugged directly into an approved receptacle, power tap or multiplug adapter and, except for approved mutliplug extension cords, shall serve _________.
Â
Â
 Possible correct answers: Â
only one portable appliance
Â
 Feedback
605.5.1
Unanswered
62% got this correct
42) Official records shall be retained for not less than 3 years.
Â
 T
 F
Â
 Feedback
104.6
Unanswered
61% got this correct
43) High-rise buildings require emergency evacuation drills ________ and shall include ________.
Â
 Quarterly, employees
 Quarterly, all occupants
 Annually, employees
 Annually, all occupants
Â
 Feedback
Table 405.2
Unanswered
73% got this correct
44) Classify the following based on occupancy:Â Fences more than 6 feet high.
Â
 F-1
 F-2
 U
 S-2
 M
Â
 Feedback
Ch. 2
Unanswered
69% got this correct
45) With regards to premises identification, address numbers shall be a minimum of ___ inches high with a minimum stroke of ___ inch(es).
Â
 3, 0.5
 4, 0.5
 3, 1
 4, 1
Â
 Feedback
505.1
Unanswered
56% got this correct
46) An approved fire safety and evacuation plan shall be prepared and maintained for Group M buildings having an occupant load of _____ or more persons or more than _____ persons above or below the lowest level of exit discharge.
(check all that apply)
Â
 100 (Missed)
 200
 300
 400
 500 (Missed)
Â
 Feedback
404.2 (11)
Unanswered
59% got this correct
47) Dumpsters and containers with an individual capacity of 1.5 cubic yards or more shall not be stored in buildings or placed within ___ feet of combustible walls, openings, or combustible eave lines.
Â
 3
 5
 10
 15
Â
 Feedback
304.3.3
Unanswered
61% got this correct
48) An operational permit is required to operate an air-supported temporary membrane structure or a tent having an area in excess of _____ square feet.
Â
 200
 250
 400
 500
Â
 Feedback
105.6.43
Unanswered
68% got this correct
49) An operational permit is required to manufacture, store or handle an aggregate quantity of __________ aerosol products in excess of 500 pounds net weight.
Â
 Level 2
 Level 3
 Level 4
 Both B and C
 Both A and B
Â
 Feedback
105.6.1
Incorrect
56% got this correct
50) Hand-held portable fire extinguishers having a gross weight exceeding ___ pounds shall be installed so that their tops are not more than ___ feet above the floor.
Â
 40, 3
 40, 5
 40, 3.5
 40, 5.5 Â