100 term per The three major phases of laboratory testing that a QA program should evaluate include
- mean, standard deviation, and coefficient of variation.
- pre-op, operative, and post-op.
- pre-analytical, analytical, and post-analytical.
- outpatient, inpatient, and non-patient.
- pre-analytical, analytical, and post-analytical.
- laboratory process control.
- laboratory calibration.
- laboratory standardization.
- laboratory verification.
- laboratory standardization.
- They contain a known amount of analyte being tested.
- They monitor the quality of reagents.
- They monitor the quality of the sample.
- They prevent equipment failure.
- They contain a known amount of analyte being tested.
The process by which test results achieve the same high levels of accuracy and precision that can be reproduced across measurement systems, laboratories and time is referred to as
What characteristics/functions do calibrators have?
An abrupt demonstrated change in the mean is a
- shift.
- trend.
- variance.
- deviation.
- shift.
- qualify for waived testing.
- produce non-numerical results.
- do not require quality control.
- do not require proficiency testing.
- produce non-numerical results.
- performance characteristic.
- performance enhancement.
- performance verification.
- performance specification.
- performance characteristic
- calibration.
- calibration verification.
- a challenge.
- quality control.
- calibration.
- CMS
- FDA
- CDC
- OSHA
- FDA
- provider moderate complexity tests.
- provider exempt status.
- provider personnel testing.
- provider performed microscopy.
- provider performed microscopy.
Qualitative examinations are those that
A property of a test that is used to describe its quality (such as accuracy, precision, sensitivity, etc.) is a
Under CLIA law, the process of testing and adjusting an instrument or test system to establish a correlation between the measured response and the concentration or amount of the substance that is being measuredby the test procedure is
What agency determines the complexity of a lab test system?
Certain moderate complexity microscopy tests (such as urine sediment evaluation and skin scrapings) commonly performed by healthcare providers in the office setting are classified as
Policies and procedures that are intended to promote the quality and validity of test data and ensure the reliability and integrity of data generated by analytical laboratories is known as
- CLIA Law.
- Quality Assurance Plan (QAP).
- Good Clinical Laboratory Practice (GCLP).
- Total Quality Management (TQM).
- Good Clinical Laboratory Practice (GCLP).
- measure quantities of various proteins in plasma, urine,
- separate enzymes into their component isoenzymes.
- identify antibodies.
- measure molecules in a characteristic spectrum called
- measure molecules in a characteristic spectrum called the emission spectrum.
- flourometry.
- atomic absorption.
- spectrophotometry.
- photometry.
- spectrophotometry.
- log %T - 2.
- log %T + 2.
- 2 + log %T.
- 2 - log %T.
- 2 - log %T.
- a workplace control.
- an engineering control.
- a best practice in the workplace.
- a human resources requirement.
- a workplace control.
- electrical malfunctions.
- faulty mechanisms.
- user error.
- crowded work conditions.
- user error.
Devices based on electrophoretic principles are used in the clinical laboratory to perform all of the following except to
and CSF.
the emission spectrum.
The chemistry methodology that is based on the fact that substances of clinical interest selectively absorb or emit electromagnetic energy at different wavelengths is
Given %T, how is absorbance calculated?
Prohibiting recapping of needles is an example of
The majority of all centrifuge accidents result from
Material Safety Data Sheets (M.S.D.S.) are now called
- Chemical Safety Sheets.
- Safety Data System.
- Material Data System.
- Safety Data Sheets.
- Safety Data Sheets.
- biosafety level of 2+ or 3.
- biosafety level 4.
- location where air exchange is continuous.
- location where fume hood exhausts are monitored
- biosafety level of 2+ or 3.
In order for a laboratory to handle TB sputum and TB materials, the laboratory must operate at a
daily.
What is the molarity of an unknown HCL solution with a specific gravity of 1.10 and an assay percentage of 18.5%?
(Atomic weights: H = 1.00794, Cl = 35.4527)
- 203.5 M
- 36.5 M
- 5.6 M
- 5.2 M
- 5.6 M
1.10 * 0.185 = 0.2035 g/mL 0.2035 g/mL * 1000 = 203.5 g/L Molarity = (g/L) / molecular weight (MW)
203.5 / 36.5 = 5.6 M
MCV = HCT * 10/(?)
- MCHC
- MCV
- RBC
- MCH
- RBC
- condenser.
- aperture.
- C-mount.
- diaphragm.
- condenser.
- high power objective multiplied by the low power
- thickness of the condenser.
- powers of the eyepiece and objective.
- fine focus adjustment.
- powers of the eyepiece and objective.
A substage lens of the microscope that focuses light on the slide specimen is the
The magnification of a microscope is determined by the
objective.