BICSI OSP, EXAM REVIEW (ACTUAL / ) QUESTIONS
AND VERIFIED CORRECT ANSWERS,
What splicing module is preferred in free breathing space in aerial applications - ----Answers---Encapsulated
In MGN power system, there may be more than one primary conductor on a line. The neutral conductor_______/ - ---- Answers---Is always below the primary
In a corrosion(High Risk area) the building ground must be separated from the OSP ground to prevent the flow of currents that may cause electrolytic corrosion. This is achieved by using_______. - ----Answers---Isolation gap
A ground at every location with a resistance to ground of____ohms or less can be accomplished by using a 8' ground rod. - ----Answers---25
_______ provide the description based on industry and commercial standards, specifications and codes and what tele.system must accomplish? - ----Answers---Performance requirements
- / 3
MINIMUM number of years for direct buried - ----Answers--- 20
IN local convergence where does all the splitting take place for PON? - ----Answers---LCP
The principle behind MH/HH intrusion detection system utilizes the fact that if the fiber is bent the______ will change and be detected. - ----Answers---Attenuation
Minimum pressures Aerial Transition Underground - ----Answers---14 kPa (2 PSI) 21 kPa (3 PSI) 34 kPa (5 PSI)
WHat chapter of NEC is communications - ----Answers--- Chapter 8
NEC chapter 770 150 - ----Answers---770- Optics 250- Bonding and grounding
75' or higher is_______ 75' or lower is_______ - ----Answers--- Zone, Cone 2 / 3
Reccomended max value for bonding resistance - ---- Answers---0.1 Ohms
Pole grade N - ----Answers---Lowest grade no load
Pole grade C - ----Answers---Medium grade, This means the line will not be shorter than grade N but not lower than B
Pole grade B - ----Answers---Highest pole grade
Bicsi says never or shall most of the time it is________ - ---- Answers---False ____ is used when the lead to height ratio is 1-1/4 or less - ---- Answers---Strait eye bolt
_____ is used when lead to height ratio is 1-1/4 or greater. - --- -Answers---Thimble eye bolt
If lead to height ratio is 3/4 or greater the head guy for the cables can be the_____as suspension strand. - ----Answers--- Same Size
If lead to height ratio is between 1/2 and 3/4 and only 2 or 3 spans the head guy should be______ than the suspension strand. - ----Answers---One Size Larger
- / 3