BICSI OSP, EXAM REVIEW (ACTUAL / ) QUESTIONS

AND VERIFIED CORRECT ANSWERS,

What splicing module is preferred in free breathing space in aerial applications - ----Answers---Encapsulated

In MGN power system, there may be more than one primary conductor on a line. The neutral conductor_______/ - ---- Answers---Is always below the primary

In a corrosion(High Risk area) the building ground must be separated from the OSP ground to prevent the flow of currents that may cause electrolytic corrosion. This is achieved by using_______. - ----Answers---Isolation gap

A ground at every location with a resistance to ground of____ohms or less can be accomplished by using a 8' ground rod. - ----Answers---25

_______ provide the description based on industry and commercial standards, specifications and codes and what tele.system must accomplish? - ----Answers---Performance requirements

  • / 3

MINIMUM number of years for direct buried - ----Answers--- 20

IN local convergence where does all the splitting take place for PON? - ----Answers---LCP

The principle behind MH/HH intrusion detection system utilizes the fact that if the fiber is bent the______ will change and be detected. - ----Answers---Attenuation

Minimum pressures Aerial Transition Underground - ----Answers---14 kPa (2 PSI) 21 kPa (3 PSI) 34 kPa (5 PSI)

WHat chapter of NEC is communications - ----Answers--- Chapter 8

NEC chapter 770 150 - ----Answers---770- Optics 250- Bonding and grounding

75' or higher is_______ 75' or lower is_______ - ----Answers--- Zone, Cone 2 / 3

Reccomended max value for bonding resistance - ---- Answers---0.1 Ohms

Pole grade N - ----Answers---Lowest grade no load

Pole grade C - ----Answers---Medium grade, This means the line will not be shorter than grade N but not lower than B

Pole grade B - ----Answers---Highest pole grade

Bicsi says never or shall most of the time it is________ - ---- Answers---False ____ is used when the lead to height ratio is 1-1/4 or less - ---- Answers---Strait eye bolt

_____ is used when lead to height ratio is 1-1/4 or greater. - --- -Answers---Thimble eye bolt

If lead to height ratio is 3/4 or greater the head guy for the cables can be the_____as suspension strand. - ----Answers--- Same Size

If lead to height ratio is between 1/2 and 3/4 and only 2 or 3 spans the head guy should be______ than the suspension strand. - ----Answers---One Size Larger

  • / 3

User Reviews

★★★★★ (5.0/5 based on 1 reviews)
Login to Review
S
Student
May 21, 2025
★★★★★

With its step-by-step guides, this document enhanced my understanding. Definitely a outstanding choice!

Download Document

Buy This Document

$1.00 One-time purchase
Buy Now
  • Full access to this document
  • Download anytime
  • No expiration

Document Information

Category: Exam (elaborations)
Added: Dec 14, 2025
Description:

BICSI OSP, EXAM REVIEW (ACTUAL / ) QUESTIONS AND VERIFIED CORRECT ANSWERS, What splicing module is preferred in free breathing space in aerial applications - ----Answers---Encapsulated In MGN power...

Unlock Now
$ 1.00