• wonderlic tests
  • EXAM REVIEW
  • NCCCO Examination
  • Summary
  • Class notes
  • QUESTIONS & ANSWERS
  • NCLEX EXAM
  • Exam (elaborations)
  • Study guide
  • Latest nclex materials
  • HESI EXAMS
  • EXAMS AND CERTIFICATIONS
  • HESI ENTRANCE EXAM
  • ATI EXAM
  • NR AND NUR Exams
  • Gizmos
  • PORTAGE LEARNING
  • Ihuman Case Study
  • LETRS
  • NURS EXAM
  • NSG Exam
  • Testbanks
  • Vsim
  • Latest WGU
  • AQA PAPERS AND MARK SCHEME
  • DMV
  • WGU EXAM
  • exam bundles
  • Study Material
  • Study Notes
  • Test Prep

- CORRECT ANSWER: - Actual Exam 100 Questions with 100% Verified Co...

Exam (elaborations) Dec 14, 2025 ★★★★★ (5.0/5)
Loading...

Loading document viewer...

Page 0 of 0

Document Text

HVAC EXCELLENCE Latest Update - Actual Exam 100 Questions with 100% Verified Correct Answers Guaranteed A+ Verified by Professor

- CORRECT ANSWER:

____ can be used for leak detection with ALL high pressure refrigerants - CORRECT

ANSWER: Soap Bubbles

10 lbs of refrigerant passing through a water cooled condenser will lose 20 BTU of heat/ pound. If 10#'s of water passes through the condenser with an entering temp of 80

degrees, the temp of the water leaving the condenser is - CORRECT ANSWER: 100

degrees faranheit

A Compound pressure gauge measures - CORRECT ANSWER: Pressure and Vacuum

A compressor that has a broken reed valve will cause these symptoms - CORRECT

ANSWER: high suction pressure and low discharge pressure

A customer complains that their AC system is running constantly, but not cooling enough. The suction line is very colde and the compressor is sweating. Mostlikely cause

is - CORRECT ANSWER: a restriction of the return air or dirty evaporator

A decrease in superheat causes the thermostatic expansion valve to - CORRECT

ANSWER: Close

a dirty evaporator in an AC system will cause these symptoms - CORRECT ANSWER:

low suction pressure and low discharge pressure. 1 / 2

A drain trap should be installed on a split system when the - CORRECT ANSWER: Air handler drain is on the negative side

a faulty condenser fan motor on an AC system will cause these symptoms - CORRECT

ANSWER: high suction pressure and high discharge pressure

A Liquid line filter drier should be placed between the - CORRECT ANSWER:

Condenser and metering device

A liquid reciever is used to - CORRECT ANSWER: Store liquid refrigerant

A liquid-to-suction heat exchanger is often used to - CORRECT ANSWER: Increase

liquid subcooling

A low pressure cut-off switch is used to - CORRECT ANSWER: Establish a minimum

operating pressure in the evaporator

A low refrigerant charge in an AC system will cause these symptoms - CORRECT

ANSWER: low suction pressure and low discharge pressure

A Mechanical shaft seal is necesssary on a - CORRECT ANSWER: Open drive

compressor

a partially clogged capillary tube metering device can cause - CORRECT ANSWER: a starved evaporator

A partially iced over evaporator can be caused by - CORRECT ANSWER: an

undercharge

  • / 2

User Reviews

★★★★★ (5.0/5 based on 1 reviews)
Login to Review
S
Student
May 21, 2025
★★★★★

This document provided step-by-step guides, which was a perfect resource for my project. Absolutely excellent!

Download Document

Buy This Document

$1.00 One-time purchase
Buy Now
  • Full access to this document
  • Download anytime
  • No expiration

Document Information

Category: Exam (elaborations)
Added: Dec 14, 2025
Description:

HVAC EXCELLENCE Latest Update - Actual Exam 100 Questions with 100% Verified Correct Answers Guaranteed A+ Verified by Professor - CORRECT ANSWER: ____ can be used for leak detection with ALL high ...

Unlock Now
$ 1.00