Document Text

Backflow Repair Technician Certification Exam (ASSE 5130) Practice Test Questions And Correct Answers (Verified Answers) Plus Rationales 2026 Q&A | Instant Download Pdf

  • Which component in a reduced pressure principle assembly discharges
  • water during normal operation?

  • Shutoff valve #2
  • Relief valve
  • First check valve
  • Test cock #1

Rationale: The relief valve between the checks opens under normal

pressure fluctuations to maintain protection.

2. The major function of a check valve in a backflow assembly is to:

  • Filter debris
  • Allow bidirectional flow 1 / 3
  • Regulate flow rate
  • Prevent reverse flow

Rationale: Check valves are one-direction components that stop reverse

flow caused by backpressure or backsiphonage.

3. A reduced pressure zone assembly provides protection against:

  • Pollution only
  • Residential cross-connections
  • Both pollution and contamination under backpressure or backsiphonage
  • Fire sprinkler water only

Rationale: RPZ assemblies offer the highest level of mechanical backflow

protection.

  • The correct order of components in a double check valve assembly from

inlet to outlet is:

  • Shutoff, relief valve, check valve, test cocks
  • Test cocks, check valve, shutoff
  • Shutoff #1, check #1, test cocks, check #2, shutoff #2
  • Relief valve, check valves, shutoff

Rationale: DCA assemblies always have check valves placed between two

shutoff valves.

5. The relief valve in an RP assembly must discharge to:

  • Any direction
  • Atmosphere
  • A closed drain 2 / 3
  • The downstream line

Rationale: Atmospheric discharge ensures reduced pressure zone integrity

if checks fail.

6. When testing a DCA, the minimum required check valve closure is:

  • 1.0 psid
  • 1.0 psid minimum across each check
  • 5.0 psid
  • 14 psi

Rationale: Both checks must close with at least 1.0 psid to ensure proper

function.

7. A failing first check valve in an RP typically causes:

  • No change in zone pressure
  • Decreased outlet pressure
  • Relief valve discharge
  • Increased inlet pressure

Rationale: If check #1 leaks, the zone pressure rises, causing relief

discharge.

  • Which tool is required to measure check valve performance?
  • Flowmeter
  • Thermometer
  • Differential pressure gauge
  • Volt meter
  • Rationale: Differential gauges read psid across checks and relief valves.

  • / 3

User Reviews

★★★★☆ (4.0/5 based on 1 reviews)
Login to Review
S
Student
May 21, 2025
★★★★☆

The practical examples offered by this document was incredibly useful for my research. A superb purchase!

Download Document

Buy This Document

$1.00 One-time purchase
Buy Now
  • Full access to this document
  • Download anytime
  • No expiration

Document Information

Category: Class notes
Added: Jan 1, 2026
Description:

Backflow Repair Technician Certification Exam (ASSE 5130) Practice Test Questions And Correct Answers (Verified Answers) Plus Rationales 2026 Q&A | Instant Download Pdf 1. Which component in a redu...

Unlock Now
$ 1.00