Illinois Fireproofing Installer Certification Examination Practice Questions And Correct Answers (Verified Answers) Plus Rationales 2026 Q&A | Instant Download Pdf (Fireproofing Materials, Application Procedures, Codes, Safety, Inspection Requirements)
- What is the primary purpose of applying spray-applied fire-resistive
- Improve building aesthetics
- Increase structural fire resistance
- Prevent corrosion
- Reduce sound transmission
materials (SFRM)?
Rationale: SFRM protects structural elements by delaying heat penetration
during a fire. 1 / 4
- Which type of fireproofing is commonly applied to steel structural
- Intumescent paint only
- Cement plaster
- Spray-applied fire-resistive material
- Gypsum board
members in commercial buildings?
Rationale: SFRM is the most widely used method for steel protection in
large structures.
3. Intumescent coatings expand when exposed to:
- Cold temperatures
- Heat
- Moisture
- UV light
Rationale: Intumescent materials swell from heat, forming an insulating
char.
- Which of the following best describes “bond strength” in fireproofing?
- Resistance to weathering
- Ability to expand under heat
- Adhesion of fireproofing to the substrate
- Surface hardness
Rationale: Bond strength measures how well fireproofing adheres to
structural surfaces. 2 / 4
5. Before applying SFRM, the substrate surface must be:
- Painted
- Wet
- Clean and free of contaminants
- Primed with latex
Rationale: Dirt, oil, rust, or paint reduce adhesion and performance.
6. The required fire-resistance rating for structural steel is determined by:
- Contractor preference
- Owner’s request
- Material cost
- Building codes and design documents
Rationale: Fire ratings come from codes and the project’s fire protection
design.
- Which environmental condition can negatively affect SFRM application?
- High humidity
- Extreme cold
- Wind
- All of the above
Rationale: All environmental factors can disrupt adhesion and curing.
8. The minimum ambient temperature for applying most SFRMs is:
A. 10°F
B. 20°F 3 / 4
C. 40°F
D. 70°F
Rationale: Most products require at least 40°F for proper bonding and
curing.
9. Fireproofing thickness is typically measured using a:
- Laser level
- Metal ruler
- Depth micrometer
- Pin depth gauge
Rationale: Pin depth gauges are the standard tool for thickness
measurements.
10. The term “intumescent” means:
- Adhesive
- Expands with heat
- Hardens under pressure
- Reacts to moisture
Rationale: Intumescent coatings expand under heat to provide insulation.
- Which type of fireproofing is most commonly used in exposed
- Cementitious SFRM
- Intumescent coatings
- / 4
architectural spaces?