A technician shows up to service the fire alarm panel in your building. What COF qualifications must he/she have?
- A Q-01/Q-99 Certificate of Qualification holder who is designated by the
- A certified Fire Safety Director who is designated by the building owner.
- A S-95 Certificate of Fitness holder who is employed by a FDNY certified
- A S-97/S-98 Certificate of Fitness holder who is employed by a FDNY certified
building owner.
company.
company. - ANSWER-D) A S-97/S-98 Certificate of Fitness holder who is employed by a FDNY certified company.
When must the Fire Department be notified that a fire protection system is out of service?
- The manual pull alarm station in the lobby will be out of service for 4 hours.
- Four sprinkler heads on a same floor of your building will be out of service for
- hours.
- The sprinkler system will be out of service on 1st and 2nd floors.
- The fire alarm system is out of service in the refrigerating system room for g
- / 4
hours. - ANSWER-C) The sprinkler system will be out of service on 1st and 2nd floors.
pg. 2 Hot work authorizations are issued by
- a Responsible Person designated by the Building Owner.
- a Building Department inspector.
- a FDNY inspector.
- the Building owner's insurance company. - ANSWER-A) a Responsible Person
designated by the building owner.
Insecticidal fogging operations are hazardous because chemicals
- are corrosive.
- are water-reactive.
- may be toxic.
- are highly unstable. - ANSWER-C) may be toxic.
In a steam turbine, what is the function of a Kingsbury thrust bearing?
- Maintain first stage steam pressure.
- Compensate for coupling misalignment.
- Adjust shaft torque at start up.
- Maintain axial positioning of the rotor shaft. - ANSWER-D) Maintain axial
positioning of the rotor shaft.
What is the lowest temperature the water in the cooling tower can be?
- Ambient. 2 / 4
pg. 3
- Between wet and dry bulb.
- Dry bulb.
- Wet bulb. - ANSWER-B) Between wet and dry bulb.
The most important reason to subcool the refrigerant in the condenser is to ensure that
- liquid slugs will not enter the compressor.
- the cooling tower has sufficient water.
- the condenser is working efficiently.
- a pure liquid refrigerant will enter the metering device. - ANSWER-D) a pure
liquid refrigerant will enter the metering device.
A chilled water system that has an air cooled condensing unit on a roof during cold weather has what type of protection?
- Glycol running through it.
- Air-limiting device.
- Heater coil.
- Resistor. - ANSWER-B) Air-limiting device.
An engineer observes a gauge that reads saturation pressure of a refrigerant. If chilled water is circulated as the cooling medium, this reading can best be used to estimate the
- chilled water return from building spaces being pumped to the spaces being
cooled. 3 / 4
pg. 4
- cooling tower efficiency.
- pressure of chilled water being pumped to spaces being cooled.
- temperature of chilled water being pumped to the spaces being cooled. -
ANSWER-D) temperature of chilled water being pumped to the spaces being cooled.
The purpose of wear rings in a centrifugal pump is to
- act as a bearing to reduce axial motion after wear occurs.
- prevent wearing of the pump housing and impeller.
- center the impeller in the pump casing.
- minimize water leakage around the shaft. - ANSWER-B) prevent wearing of
the pump housing and impeller.
Of the follow, an example of an in-line refrigerant cleaning system that may be
used with a centrifugal compressor containing R123 refrigerant is:
- Refrigerant reclaiming.
- Refrigerant disposal.
- Refrigerant recycling.
- Refrigerant recovery. - ANSWER-C) Refrigerant recycling.
Refrigerating system refrigerant detection systems must be tested at least
- annually.
- monthly.
- daily.