Fire Extinguishing Systems Inspection, Testing,

Class notes Jan 3, 2026 ★★★★☆ (4.0/5)
Loading...

Loading document viewer...

Page 0 of 0

Document Text

FDNY S17 Commercial Cooking Wet Chemical Fire Extinguishing Systems Inspection, Testing, and Servicing Technician (Citywide) Practice Exam Questions And Correct Answers (Verified Answers) Plus Rationales 2026 Q&A | Instant Download Pdf

  • Which NFPA standard governs wet chemical extinguishing systems for
  • commercial cooking?

A. NFPA 10

B. NFPA 17

C. NFPA 17A

D. NFPA 96

Answer: C

Rationale: NFPA 17A specifically covers wet chemical extinguishing

systems.

  • The primary extinguishing agent in most commercial cooking wet

chemical systems is: 1 / 4

  • Halon 1211
  • Water mist

C. CO₂

  • Potassium-based solution

Answer: D

Rationale: Wet chemical systems rely on potassium salts for saponification

of hot grease.

  • What process converts hot grease to a soapy layer during
  • extinguishment?

  • Oxidation
  • Combustion
  • Emulsification
  • Saponification

Answer: D

Rationale: Potassium-based agents react with fats to create a non-

flammable soapy foam layer.

  • How often must commercial cooking exhaust systems be inspected?
  • Monthly
  • Every 6 months
  • Annually
  • Every 2 years

Answer: B

Rationale: FDNY and NFPA 96 require semiannual inspections. 2 / 4

5. Fusible links in a wet chemical system must be replaced:

  • Only when damaged
  • Every 5 years
  • Every 6 months
  • Every 3 months

Answer: C

Rationale: Fusible links are replaced at each semiannual inspection.

6. The manual pull station for the system must be located:

  • Next to the fryer
  • Inside the hood
  • Above the cookline
  • 10–20 ft from cooking appliances

Answer: D

Rationale: Manual pulls must be accessible yet away from immediate fire

danger.

7. Upon system activation, gas and electric power to appliances must:

  • Stay on
  • Reset automatically
  • Shut off
  • Switch to low power

Answer: C

Rationale: Fuel shutoff is required to stop heat production. 3 / 4

8. The test method for verifying nozzle alignment is:

  • Ultrasonic testing
  • Visual inspection
  • Pressure test
  • Thermal imaging

Answer: B

Rationale: Technicians must visually verify proper nozzle orientation.

9. System cylinders must be hydrostatically tested every:

  • 2 years
  • 3 years
  • 12 years
  • 15 years

Answer: C

Rationale: NFPA requires a 12-year hydro test for wet chemical cylinders.

10. The K-class portable extinguisher must be located within:

  • 100 ft
  • 50 ft
  • 20 ft
  • 30 ft

Answer: D

Rationale: NFPA 10 requires K-class units within 30 ft of cooking

equipment.

  • / 4

User Reviews

★★★★☆ (4.0/5 based on 1 reviews)
Login to Review
S
Student
May 21, 2025
★★★★☆

This document featured detailed explanations that was incredibly useful for my research. Such an excellent resource!

Download Document

Buy This Document

$1.00 One-time purchase
Buy Now
  • Full access to this document
  • Download anytime
  • No expiration

Document Information

Category: Class notes
Added: Jan 3, 2026
Description:

FDNY S17 Commercial Cooking Wet Chemical Fire Extinguishing Systems Inspection, Testing, and Servicing Technician (Citywide) Practice Exam Questions And Correct Answers (Verified Answers) Plus Rati...

Unlock Now
$ 1.00