IBC UPDATED Exam (Actual / ) 266 Questions And 100% Verified CORRECT Answers
Buildings that contain materials that pose a detonation hazard shall be classified as Group ____
GROUP H-1
A group I-1 occupancy shall include a building or part thereof for more than ____ persons who reside on a 24-hour basis in a supervised environment and receive custodial care.16
Semiconductor fabrication facilities and comparable research and development areas in which hazardous production materials (HPM) are used are classified as Group ____ H-5
Covered mall buildings exceeding ____ square feet shall be provided with emergency power systems that are capable of operating the emergency voice/alarm communication system.
50,000
- / 4
In a high-rise building, every required interior exit stairway serving floors more than 75 feet above the lowest level of fire department vehicle access shall be a ___ ___.smoke-proof enclosure.
In high-rise buildings, electrically powered fire pumps are classified as ___ power loads.emergency
Atrium spaces shall be separated from adjacent spaces by a ____ -hour fire barrier.1
The provisions of Section 405 Underground Buildings apply to building spaces having a floor level used for human occupancy more than ____ feet below the finished floor of the lowest level of exit discharge.30
A building having a floor level more than ____ feet below the finished floor of the lowest level of exit discharge shall be divided into a minimum of two compartments of approximately equal size. 2 / 4
60
Carports open on fewer than two sides shall be considered to be a ____ garage
Repair garage floors shall be of ____ or similar non- combustible and nonabsorbent materials concrete
Repair garages shall be _____ ventilated in accordance with the International Mechanical Code mechanically ventilated
Motor vehicle service station canopies under which fuels are dispensed shall have a clear, unobstructed height of not less than ____ ____ to the lowest projecting element in the vehicle drive-through area.13 feet 6 inches
- / 4
Openings from a parking garage directly into a room used for ____ ____ shall not be permitted sleeping purposes
In public parking garages, vehicle barriers, where required, must be a minimum of ____ ____ in height.
- feet 9 inches
In public parking garages, the clear height of each floor level in vehicle and pedestrian traffic areas shall be not less than ____ feet.7
Where openings below grade provide the required natural ventilation for an open parking garage, the outside horizontal clear space shall be ____ times the depth of the opening.one and one half (1 and 1/2)
In Group I-2 occupancies, spaces for doctors' and nurses' charting, communications and related clerical areas shall be permitted to be ____ to the corridor, where such spaces are constructed as required for corridors.open
- / 4