• wonderlic tests
  • EXAM REVIEW
  • NCCCO Examination
  • Summary
  • Class notes
  • QUESTIONS & ANSWERS
  • NCLEX EXAM
  • Exam (elaborations)
  • Study guide
  • Latest nclex materials
  • HESI EXAMS
  • EXAMS AND CERTIFICATIONS
  • HESI ENTRANCE EXAM
  • ATI EXAM
  • NR AND NUR Exams
  • Gizmos
  • PORTAGE LEARNING
  • Ihuman Case Study
  • LETRS
  • NURS EXAM
  • NSG Exam
  • Testbanks
  • Vsim
  • Latest WGU
  • AQA PAPERS AND MARK SCHEME
  • DMV
  • WGU EXAM
  • exam bundles
  • Study Material
  • Study Notes
  • Test Prep

Master Electrician Practice Test Latest

Exam (elaborations) Dec 14, 2025 ★★★★★ (5.0/5)
Loading...

Loading document viewer...

Page 0 of 0

Document Text

Master Electrician Practice Test Latest Update - Questions with 100% Verified Correct Answers Guaranteed A+ Verified by Professor

  • The optional method of calculation for dwelling
  • units is reserved for ___.

  • multifamily dwelling units only
  • dwelling units with over 3,000 sq. ft. of usable
  • space

  • dwelling units supplied by service conductors
  • with an ampacity of 100 amperes or greater.

  • dwelling units with a 208Y/120-volt, 3-phase,
  • electrical system only

Study Online Instantly

  • When calculating the service-entrance
  • conductors of a farm where all the buildings, including the dwelling, are supplied from a common service, the second largest individual load in the group shall be calculated at _____.

  • 60
  • percent

  • 75
  • percent

  • 80
  • percent

  • 90
  • percent

  • / 2
  • The entire area of a service pit located in a commercial major repair garage that is not
  • provided with mechanical ventilation is classified as a _____ location.

  • Class I, Division 1
  • Class I, Division 2
  • Class II, Division 1
  • Class II, Division 2
  • The MAXIMUM distance conduit seals are permitted to be installed from an enclosure
  • that houses devices that produces arcs or high-temperatures in a Class I, Division 1 location is _____.

  • 6 inches
  • 24 inches
  • 12 inches
  • 18 inches
  • Where three (3) switches are grouped or
  • ganged in an outlet box without permanent barriers, the voltage between the adjacent switches shall NOT exceed _____.

  • 150 volts
  • 250 volts
  • 300 volts
  • 240 volts

Study Online Instantly

  • In order to determine the adequate size of a
  • junction box containing size 4 AWG THWN copper conductors, the volume allowance, in cubic inches, required per conductor is _____.

  • 5.00 cu. in.
  • / 2

User Reviews

★★★★★ (5.0/5 based on 1 reviews)
Login to Review
S
Student
May 21, 2025
★★★★★

I was amazed by the detailed explanations in this document. It helped me ace my presentation. Truly impressive!

Download Document

Buy This Document

$1.00 One-time purchase
Buy Now
  • Full access to this document
  • Download anytime
  • No expiration

Document Information

Category: Exam (elaborations)
Added: Dec 14, 2025
Description:

Master Electrician Practice Test Latest Update - Questions with 100% Verified Correct Answers Guaranteed A+ Verified by Professor 1. The optional method of calculation for dwelling units is reserve...

Unlock Now
$ 1.00