NICET Fire Alarm Sample Exam Latest Update

Exam (elaborations) Dec 14, 2025 ★★★★★ (5.0/5)
Loading...

Loading document viewer...

Page 0 of 0

Document Text

NICET Fire Alarm Sample Exam Latest Update - with 250 Questions and Verified Correct Answers Golden Ticket to Guaranteed A+ Verified by Professor

A facility that provides supervised and personal care on a 24 hour basis for more than 5 children 2 1/2 years of age or less shall be classified as ___? - CORRECT ANSWER: Group I-2

A fire alarm system which serves contiguous or noncontiguous properties under one

ownership is considered? - CORRECT ANSWER: Proprietary system

According to the IBC, which Use Groups which have required fire alarm systems shall utilize visible notification appliances? - CORRECT ANSWER: ALL use groups require visible notification appliances

Activation of the initiating device shall occur within ___ of water flow at the alarm-

initiating device. - CORRECT ANSWER: 90 seconds

Air sampling network piping shall be conspicuously identified at? - CORRECT

ANSWER: Changes in direction,

Each side of penetrations, Intervals not to exceed 20ft

All fire alarm system wiring shall be___. - CORRECT ANSWER: Supported by the

permanent building structure

An initiating device which is destroyed as a result of operation is what type? -

CORRECT ANSWER: Nonrestorable

  • / 2

Consider a circuit of 1000 feet (total) of coated 18 AWG FPL from a 24 VDC FACP to an initiating device, with a circuit amperage of 1 amp. At 75C, what voltage is present at the

device? - CORRECT ANSWER: I x R = Voltage Drop

  • A x 8.1 ohms
  • 8.1 v 24 v - 8.1 ohms = 15.9 v

Consider a Group M Use Group where the entire building is 1 story at the level of exit discharge. At what occupant load is a fire alarm system required? - CORRECT

ANSWER: 500

Consider a Group R-1 with 80 sleeping units. How many of the rooms shall be equipped with visible alarm notification appliances activated by both the in room smoke alarm and

the building fire alarm system? - CORRECT ANSWER: 9

Consider a simple series circuit with a 24VDC power supply and a single 240 ohm

resister. What is the current for this circuit. - CORRECT ANSWER: .10 amps

(24v/240ohm = .10 amp)

Duct smoke detectors are required to ___? - CORRECT ANSWER: Be connected to the

building fire alarm system

Equipment constructed and installed in conformity with NFPA 72 shall be? - CORRECT

ANSWER: Listed

Fire power limited cabling used for runs between floors shall be of what type? -

CORRECT ANSWER: FPLR and FPLP

For fire power limited cable what is the smallest multiconductor size and smallest single

conductor size? - CORRECT ANSWER: 26 AWG multiconductor,

18 AWG single conductor

  • / 2

User Reviews

★★★★★ (5.0/5 based on 1 reviews)
Login to Review
S
Student
May 21, 2025
★★★★★

With its step-by-step guides, this document was a perfect resource for my project. Definitely a excellent choice!

Download Document

Buy This Document

$1.00 One-time purchase
Buy Now
  • Full access to this document
  • Download anytime
  • No expiration

Document Information

Category: Exam (elaborations)
Added: Dec 14, 2025
Description:

NICET Fire Alarm Sample Exam Latest Update - with 250 Questions and Verified Correct Answers Golden Ticket to Guaranteed A+ Verified by Professor A facility that provides supervised and personal ca...

Unlock Now
$ 1.00