NIOSH 7400 METHOD NEWEST ACTUAL / QUESTIONS
WITH ANSWERS VERIFIED/GRADED A+
T/F: although confidence limit and control limit both are
abbreviated CL, at times they both can be the same value - --- -Answers---true
T/F: one must always observe 100 fields on a sample - ----
Answers---false (always 20 fields)
as a minimum occurrence, how often should recounts be
performed? one out of every: - ----Answers---10 (or 10%)
T/F: to prepare a permanent slide, one needs acetone and
triacetin which are mixed together in a 1:1 solution by volume -
----Answers---naaaahh, False
one of the liquids used to prepare permanent slides is: - ----
Answers---triacetin
T/F: as the count on a light sample increases, one expects the
variation associated with the count to increase also - ---- Answers---false
T/F: the HSE/NPL mark 2 test slide is used to investigate the
microscopes resolution - ----Answers---true
- / 2
the specified tolerance of a Walron-Beckett graticules field diameter is 100 + or - how many micrometers? - ---- Answers---2
a stage micrometer is used to test the resolution and contrast (overall image quality of the microscope) - ----Answers--- falso
for Kohler illumination, what are the three steps to calibrating your microscope? - ----Answers---1. focus on the sample
- Field Iris
- phase rings
how do you order a Walton Beckett graticule - ----Answers-- -1. take the actual diameter of W/B
- take the diameter of the glass
- order the W/B G-22
the numerical aperture range specified in method #7400 is: - -
---Answers---.65-.75
for the A counting rules, which version of the Walton Beckett graticule is used? - ----Answers---G-22
if the diameter of a Walton Beckett graticule is 100 micrometers, what is the field area in square millimeters? - -- --Answers---.00785 mm squared
- / 2