- What is the primary purpose of a rapid shutdown system on a PV array?
- Increase energy production
- Reduce voltage to safe levels during emergencies
- Improve grounding continuity
- Prevent shading issues
Rationale: Rapid shutdown ensures firefighter safety by reducing energized
conductors quickly.
- Which factor most affects the current output of a PV module?
- Module voltage rating
- Solar irradiance 1 / 4
- Temperature coefficient
- Wire gauge
Rationale: Current is directly proportional to irradiance.
- A PV system using a 600 VDC array must use components rated for at
least:
A. 500 VDC
B. 600 VDC
C. 550 VDC
D. 700 VDC
Rationale: Components must meet or exceed the maximum system
voltage.
4. The main purpose of bonding is to:
- Improve array efficiency
- Reduce module degradation
- Create a low-impedance fault path
- Prevent inverter clipping
Rationale: Bonding ensures faults clear quickly by providing an effective
grounding path.
5. Temperature rise in PV modules generally:
- Increases voltage
- Decreases voltage
- Increases both current and voltage 2 / 4
- Does not change output
Rationale: Higher cell temperature lowers module Voc.
- Which device converts DC from modules to usable AC power?
- Charge controller
- Inverter
- Transformer
- Combiner
Rationale: Inverters perform DC-to-AC conversion.
- What determines the number of modules in a series string?
- Tilt angle
- Maximum inverter input voltage
- Grounding method
- Conductor insulation type
Rationale: Series voltage cannot exceed inverter voltage limits.
8. The NEC requires overcurrent protection on PV source circuits when:
- Using microinverters
- Parallel strings can backfeed each other
- Arrays exceed 1 kW
- AC modules are installed
Rationale: Parallel strings create potential backfeed currents.
- A module’s STC power rating is measured at: 3 / 4
- 500 W/m²
- 1500 W/m²
- 1000 W/m²
- 2000 W/m²
Rationale: STC irradiance is defined as 1000 W/m².
- Which conductor is typically grounded in a PV system?
- Ungrounded conductor
- Equipment grounding conductor
- Grounded current-carrying conductor
- Neutral and ground together
Rationale: The grounded conductor is intentionally bonded to ground.
11. A major advantage of microinverters is:
- Lower installation cost
- Module-level MPPT
- Lower AC voltage
- No need for grounding
Rationale: Microinverters optimize each module individually.
12. String sizing must account for the module’s:
- Pmax only
- Voc and temperature coefficient
- ISC only
- Weight rating