Question 1: Work Area Sterilizer loading/unloading
1) Air exchanges 2) Airflow 3) Temperature 4) Humidity
Answer:
1) Air exchanges: 10
2) Airflow: Positive, out
3) Temperature: 68-73 F (20-23
C)
4) Humidity: 30-60%
Question 2: What items require only high-level disinfection based on the
Spaulding criteria?
- Non-critical items
- Semi-critical items
- Critical items
Answer:
Semi critical: Mucous membranes or non-intact skin: endoscopes; Vaginal probes; High level Disinfection
Question 3: What is the temperature required for flash steam sterilization?
A. 100°C/212°F
B. 132°C/ 270°F
C. 150°C/302°F
D. 172 °C/342 °F
Answer:
B. 132°C/ 270°F
Flash sterilization is done at 132C/270F and may be used on both porous and nonporous items although the time needed for sterilization may vary from 3 to 10 minutes, depending on the item being sterilized.Question 4: Vaginal probes with probe covers require which type of disinfection:
- Low-level disinfection
- Intermediate-level disinfection
- High-level disinfection
- Sterilization
Answer:
- High-level disinfection
Question 5: Work Area Sterilizer equipment access rooms
1) Air exchanges 2) Airflow 3) Temperature 4) Humidity
Answer:
1) Air exchanges: 10
2) Airflow: Negative
3) Temperature: 75-85 F (24-29
C) 4) Humidity 30-60% Question 6: Equipment that uses hot water for a definite period to destroy pathogenic bacteria; often used for respiratory therapy and anesthesia equipment
Answer:
Pasteurizer
Question 7: In an effort to reduce cost and decrease turn around time, the
endoscopy manager has asked if the enzymatic detergent can be
used for multiple patients. Your response is:
Answer:
- The enzymatic detergent must be discarded after each use. The CDC recommends that the
enzymatic detergent be discarded after each use since these products are not antimicrobial & will not retard microbial growth.
Question 8: Reprocessing
Answer:
to the validated cleaning and high-level disinfection or sterilization of reusable endoscopic devices by either manual or automated methods
Question 9: Which of the following are CDC requirements for storing
endoscopes?
Answer:
- Store hanging in a vertical position to facilitate drying
- Store in a manner that protects the scope from contamination
Store in a manner that protects them from contamination. Hang it in a vertical position to facilitate drying Question 10: Concept that items are considered sterile unless the integrity of the packaging is compromised (i.e., torn, soiled, wet, or showing evidence of tampering). Shelf life is indefinite.
Answer:
Event-related sterility
Question 11: Semi-critical
Answer:
objects which touch mucous membranes or skin that is not intact
Question 12: In the late 1950s and early 1960s, ethylene oxide (EO) sterilizers
were developed to address the reprocessing of heat-sensitive devices. True or False
Answer:
True
Question 13: A pt in Droplet Precautions is scheduled for a procedure in
Endoscopy. In addition to following respiratory hygiene & cough etiquette, which of the following is the most appropriate method to reduce the transmission during transportation of the pt?
Answer:
- Place a surgical mask on the patient
- Surgical instrument
- Prosthetic implant
- Endoscope
- Blood pressure cuff
Question 14: Under the Spalding system, which of the following is classified as a semi-critical item when considering methods for sterilization.