• wonderlic tests
  • EXAM REVIEW
  • NCCCO Examination
  • Summary
  • Class notes
  • QUESTIONS & ANSWERS
  • NCLEX EXAM
  • Exam (elaborations)
  • Study guide
  • Latest nclex materials
  • HESI EXAMS
  • EXAMS AND CERTIFICATIONS
  • HESI ENTRANCE EXAM
  • ATI EXAM
  • NR AND NUR Exams
  • Gizmos
  • PORTAGE LEARNING
  • Ihuman Case Study
  • LETRS
  • NURS EXAM
  • NSG Exam
  • Testbanks
  • Vsim
  • Latest WGU
  • AQA PAPERS AND MARK SCHEME
  • DMV
  • WGU EXAM
  • exam bundles
  • Study Material
  • Study Notes
  • Test Prep

ACI Concrete Field Testing Technician

Class notes Jan 3, 2026 ★★★★☆ (4.0/5)
Loading...

Loading document viewer...

Page 0 of 0

Document Text

ACI Concrete Field Testing Technician Grade I Certification Exam Practice Questions And Correct Answers (Verified Answers) Plus Rationales 2026 Q&A | Instant Download Pdf

  • What is the primary purpose of ASTM standards in concrete testing?
  • To reduce construction costs
  • To ensure uniform testing procedures
  • To provide standardized methods for testing concrete materials
  • To replace local building codes

Italicized Rationale: ASTM standards ensure consistency, reliability,

and comparability of concrete test results across projects and laboratories.

  • Which ASTM standard covers sampling fresh concrete?

A. ASTM C39

B. ASTM C172 1 / 4

C. ASTM C31

D. ASTM C143

Italicized Rationale: ASTM C172 specifically addresses procedures for

sampling freshly mixed concrete.

  • What is the minimum size of a composite sample according to ASTM
  • C172?

  • 0.5 cubic feet
  • 1 cubic foot
  • 1.5 cubic feet
  • 2 cubic feet

Italicized Rationale: ASTM C172 requires a composite sample of at

least 1 cubic foot to ensure representativeness.

  • Which test determines the consistency of fresh concrete?
  • Air content test
  • Unit weight test
  • Slump test
  • Strength test

Italicized Rationale: The slump test (ASTM C143) measures the

consistency and workability of fresh concrete.

  • What is the height of the slump cone?
  • 8 inches
  • 10 inches
  • 12 inches 2 / 4
  • 14 inches

Italicized Rationale: The standard slump cone height is 12 inches as

specified in ASTM C143.

  • How many layers are used when filling the slump cone?
  • Two
  • Three
  • Four
  • Five

Italicized Rationale: The slump cone is filled in three equal layers,

each rodded 25 times.

  • What is the diameter of the slump cone base?
  • 6 inches
  • 7 inches
  • 8 inches
  • 10 inches

Italicized Rationale: The base diameter of the slump cone is 8 inches

per ASTM requirements.

  • How many times is each layer rodded during the slump test?
  • 10
  • 15
  • 25

D. 50 3 / 4

Italicized Rationale: Each layer is rodded 25 times to properly

consolidate the concrete.

  • When should the slump test be performed after sampling?
  • Within 5 minutes
  • Within 15 minutes
  • Within 30 minutes
  • Within 1 hour

Italicized Rationale: ASTM C143 requires the slump test to begin

within 15 minutes after sampling.

  • What does an excessively high slump indicate?
  • Low water content
  • Too much water in the mix
  • Proper workability
  • High strength

Italicized Rationale: A very high slump often indicates excess water,

which can reduce strength and durability.

  • Which test measures the air content of freshly mixed concrete
  • by pressure method?

A. ASTM C138

B. ASTM C231

C. ASTM C173

  • ASTM C39
  • / 4

User Reviews

★★★★☆ (4.0/5 based on 1 reviews)
Login to Review
S
Student
May 21, 2025
★★★★☆

This document provided step-by-step guides, which enhanced my understanding. Absolutely excellent!

Download Document

Buy This Document

$1.00 One-time purchase
Buy Now
  • Full access to this document
  • Download anytime
  • No expiration

Document Information

Category: Class notes
Added: Jan 3, 2026
Description:

ACI Concrete Field Testing Technician Grade I Certification Exam Practice Questions And Correct Answers (Verified Answers) Plus Rationales 2026 Q&A | Instant Download Pdf 1. What is the primary pur...

Unlock Now
$ 1.00