CA C10 Electrical Contractor Exam Questions And Correct Answers (Verified Answers) Plus Rationale2026 Q&A| Instant Download Pdf

  • What is the maximum allowable voltage drop for branch circuits in a
  • residential dwelling?

  • 1%
  • 3%
  • 5%

D. 10%

Rationale: The NEC recommends a maximum voltage drop of 5% for

branch circuits to ensure efficient operation of electrical equipment and minimize energy loss.

  • Which type of conduit is typically used for outdoor installations
  • exposed to moisture?

A. EMT

B. PVC

C. IMC

D. RMC

Rationale: PVC conduit is non-metallic, corrosion-resistant, and

suitable for wet locations.

  • A 20-ampere circuit breaker is installed in a branch circuit. What is the
  • maximum size copper wire allowed?

A. 12 AWG

B. 12 AWG

C. 10 AWG

D. 14 AWG

Rationale: NEC allows 12 AWG copper wire for a 20-ampere circuit;

using larger wire is allowed but not necessary.

  • What is the primary function of a GFCI outlet?
  • Protect equipment 1 / 3
  • Protect people from electric shock
  • Reduce voltage drop
  • Increase current flow

Rationale: Ground Fault Circuit Interrupters detect differences in

current and quickly disconnect power to prevent electrical shock.

  • Which type of wiring method is permitted in damp locations?
  • NM cable
  • AC cable (Armored Cable)
  • UF cable
  • SE cable

Rationale: Armored cable (AC) is approved for use in damp

locations; NM cable is not rated for wet or damp areas.

  • What is the minimum clearance for service panels in front of electrical
  • equipment?

  • 24 inches
  • 28 inches
  • 36 inches
  • 48 inches

Rationale: NEC requires 36 inches of clear working space in front of

service panels for safety and accessibility.

  • What is the NEC color code for a grounded conductor in residential
  • wiring?

  • White or gray
  • Black
  • Red
  • Green

Rationale: Grounded conductors (neutrals) are white or gray

according to NEC color codes.

  • Which device protects circuits from short circuits and overloads?
  • Fuse
  • Circuit breaker
  • Transformer
  • Receptacle

Rationale: Circuit breakers automatically disconnect power during

overcurrent or short circuit conditions.

  • What is the purpose of bonding in electrical systems?
  • Reduce power usage 2 / 3
  • Provide a low-resistance path to ground
  • Increase voltage
  • Protect from voltage drop

Rationale: Bonding ensures that all metal parts are electrically

connected, preventing potential shock hazards.

  • When installing electrical boxes in a wall, what is the minimum
  • box depth for standard residential outlets?

  • 1-1/2 inches
  • 2 inches
  • 2-1/2 inches
  • 3 inches

Rationale: Standard electrical boxes must accommodate wire

connections and devices; NEC requires at least 2-1/2 inches depth for outlets.

  • What is the typical voltage for a single-phase residential service?
  • 120V only
  • 240V only

C. 120/240V

D. 208V

Rationale: Residential services typically use 120/240V single-phase

systems for standard appliances and lighting.

  • Which NEC article governs grounding and bonding?
  • Article 210
  • Article 220
  • Article 250
  • Article 300

Rationale: NEC Article 250 covers grounding, bonding, and related

requirements.

  • What is the maximum ampacity of 14 AWG copper wire in a
  • residential branch circuit?

A. 10A

B. 15A

C. 20A

D. 25A

Rationale: NEC allows 14 AWG copper wire to carry up to 15

amperes for branch circuits.

  • / 3

User Reviews

★★★★☆ (4.0/5 based on 1 reviews)
Login to Review
S
Student
May 21, 2025
★★★★☆

This document provided in-depth analysis, which made learning easy. Absolutely outstanding!

Download Document

Buy This Document

$1.00 One-time purchase
Buy Now
  • Full access to this document
  • Download anytime
  • No expiration

Document Information

Category: Class notes
Added: Jan 3, 2026
Description:

CA C10 Electrical Contractor Exam Questions And Correct Answers (Verified Answers) Plus Rationale2026 Q&A| Instant Download Pdf 1. What is the maximum allowable voltage drop for branch circuits in ...

Unlock Now
$ 1.00