CA C16 FIRE PROTECTION

Class notes Jan 3, 2026 ★★★★☆ (4.0/5)
Loading...

Loading document viewer...

Page 0 of 0

Document Text

CA C16 FIRE PROTECTION

CONTRACTOR EXAM Questions And Correct Answers (Verified Answers) Plus Rationale2026 Q&A| Instant Download Pdf

  • What is the minimum pressure required for a hydrostatic test on a fire
  • sprinkler system?

  • 100 psi
  • 200 psi
  • 250 psi
  • 300 psi

Rationale: NFPA 13 requires a minimum hydrostatic test of 200 psi or 50

psi above system pressure.

  • Which document governs installation of automatic sprinkler systems?

A. NFPA 25

B. NFPA 13

C. NFPA 72

D. NFPA 20

Rationale: NFPA 13 is the primary installation standard for sprinkler

systems.

  • / 3

3. Standpipe systems are primarily installed for use by:

  • Security personnel
  • Firefighters
  • Building owners
  • Maintenance contractors

Rationale: Standpipes provide hose connections for fire department

operations.

4. A fire pump must be performance-tested:

  • Monthly
  • Quarterly
  • Annually
  • Every 5 years

Rationale: NFPA 25 mandates annual flow testing for fire pumps.

  • What type of sprinkler system uses air pressure instead of water?
  • Wet system
  • Dry system
  • Deluge system
  • Preaction system

Rationale: Dry systems use pressurized air or nitrogen to hold water back.

6. The main purpose of a backflow prevention assembly is to prevent:

  • Excess pressure
  • Pipe corrosion
  • Contamination of potable water
  • Waterflow surges

Rationale: Backflow devices stop fire system water from returning to

potable lines. 2 / 3

7. A Class I standpipe system provides hose connections intended for:

  • Occupants only
  • Maintenance personnel
  • Fire department personnel
  • Security guards

Rationale: Class I systems are designed with 2½-inch hose connections for

firefighters.

  • What is the minimum clearance below sprinkler deflectors in most
  • occupancies?

  • 6 inches
  • 10 inches
  • 18 inches
  • 24 inches

Rationale: NFPA 13 specifies 18-inch clearance for storage and

obstruction control.

9. Fire pump controllers must be installed:

  • Outside the pump room
  • In a basement
  • In the same room as the fire pump
  • On the roof

Rationale: NFPA 20 requires controllers to be close to the pump for

coordination.

  • Which valve must be supervised for a sprinkler system to remain in
  • service?

  • / 3

User Reviews

★★★★☆ (4.0/5 based on 1 reviews)
Login to Review
S
Student
May 21, 2025
★★★★☆

The comprehensive coverage offered by this document made learning easy. A remarkable purchase!

Download Document

Buy This Document

$1.00 One-time purchase
Buy Now
  • Full access to this document
  • Download anytime
  • No expiration

Document Information

Category: Class notes
Added: Jan 3, 2026
Description:

CA C16 FIRE PROTECTION CONTRACTOR EXAM Questions And Correct Answers (Verified Answers) Plus Rationale2026 Q&A| Instant Download Pdf 1. What is the minimum pressure required for a hydrostatic test ...

Unlock Now
$ 1.00