CA C36 Plumbing Contractor Exam Questions And Correct Answers (Verified Answers) Plus Rationale2026 Q&A| Instant Download Pdf
- Which of the following is the standard minimum slope for a 2-inch
- 1/8 inch per foot
- 1/4 inch per foot
- 1/2 inch per foot
- 1 inch per foot
diameter horizontal drain pipe?
Rationale: A 1/4 inch per foot slope ensures proper drainage and
prevents solids from settling in a 2-inch pipe.
- What is the primary purpose of a vent in a plumbing system?
- To increase water pressure
- To allow air into the drainage system and prevent siphoning of
- To filter water
- To heat water
traps
Rationale: Vents maintain atmospheric pressure in the pipes and
prevent traps from losing their water seal.
- Which type of pipe is commonly used for underground water supply?
A. CPVC
B. PVC
- Ductile iron
- Galvanized steel
Rationale: Ductile iron is durable and resistant to underground
corrosion, making it ideal for buried water mains. 1 / 3
- The maximum allowable distance between supports for a horizontal
PVC pipe of 3 inches in diameter is:
- 4 feet
- 6 feet
- 8 feet
- 10 feet
Rationale: PVC pipes must be supported at intervals specified by code
to prevent sagging; 3-inch pipes typically require 8-foot spacing.
- What is the function of a trap in a plumbing fixture?
- To increase water flow
- To prevent sewer gases from entering the building
- To regulate water pressure
- To filter debris
Rationale: Traps hold water that blocks sewer gases from rising into
occupied spaces.
- A plumber is installing a water heater. Which of the following is
- Globe valve
- Gate valve
- Check valve
- Angle valve
required to prevent backflow?
Rationale: Check valves allow water to flow in one direction,
preventing contamination of the potable water supply.
- In a residential building, what is the minimum pipe diameter for a main
- 2 inches
- 4 inches
- 6 inches
- 8 inches
sewer line?
Rationale: 4-inch diameter is the minimum standard for residential
building sewer mains to handle expected waste flow.
- Which of the following materials is suitable for hot water distribution?
A. PVC
B. CPVC
- Galvanized iron
- Polyethylene 2 / 3
Rationale: CPVC is rated for hot water use, unlike standard PVC,
which may deform at high temperatures.
- What type of joint is typically used to connect cast-iron soil pipes?
- Solvent cement
- Threaded
- Hub-and-spigot with lead and oakum
- Compression fitting
Rationale: Hub-and-spigot joints with lead and oakum create
watertight seals for cast-iron soil pipes.
- What is the purpose of an expansion tank in a closed water
- To heat water faster
- To absorb pressure changes and prevent pipe damage
- To filter water
- To store extra water
heating system?
Rationale: Expansion tanks prevent excessive pressure buildup when
water expands due to heating.
11. The water hammer in a plumbing system is caused by:
- Low water temperature
- Sudden closure of a valve
- Leaking pipes
- Incorrect pipe slope
Rationale: Rapidly closing valves cause pressure surges known as
water hammer.
- What is the correct order of operations for joining copper pipes
- Heat, clean, apply flux, solder
- Clean, apply flux, heat, solder
- Apply flux, solder, heat, clean
- Heat, solder, clean, flux
using soldering?
Rationale: Cleaning removes oxidation, flux prevents oxidation during
heating, and solder is applied to a heated joint for bonding.
- For a proper plumbing system, the minimum size of a vent pipe
serving a single fixture is:
- 3/4 inch
- 1 inch
- 1 1/4 inch
- / 3