- Which component is primarily responsible for converting engine
power into hydraulic pressure on a fire pump?
a) Engine governor
b) Pump panel
c) Pump drive
d) Transmission
Rationale: The pump drive connects the engine to the pump, allowing
engine power to be converted into hydraulic pressure for firefighting operations.
- What type of pump is commonly used on fire apparatus for large-
volume water supply? 1 / 4
a) Centrifugal pump
b) Single-stage centrifugal pump
c) Gear pump
d) Positive displacement pump
Rationale: Single-stage centrifugal pumps are standard on fire apparatus
because they provide high flow rates and can operate at various pressures.
- When performing a pump test, the gauge readings are lower than
expected. What is the most likely cause?
a) Air in the system
b) Partial obstruction in the pump intake
c) Engine overheating
d) Low battery voltage
Rationale: A partial obstruction restricts water flow, causing lower
pressure readings during a pump test.
- Which NFPA standard specifies requirements for automotive fire
apparatus?
a) NFPA 1901
b) NFPA 1002
c) NFPA 1500
d) NFPA 1911
Rationale: NFPA 1911 covers inspection, maintenance, testing, and
retirement of in-service fire apparatus, ensuring safe operation. 2 / 4
- What is the primary function of a pressure relief valve on a fire pump?
a) Increase pump pressure
b) Direct water to hoses
c) Prevent over-pressurization
d) Filter debris
Rationale: Pressure relief valves protect the pump and connected lines
from excessive pressure, which could cause damage or hose failure.
- What is the standard method for priming a centrifugal fire pump?
a) Mechanical suction
b) Using a primer pump or vacuum
c) Opening discharge valves
d) Running the engine at idle
Rationale: Centrifugal pumps must be primed to remove air; a primer
pump or vacuum ensures water enters the pump properly.
- What type of fluid is recommended for most aerial device hydraulic
systems?
a) Engine oil
b) Brake fluid
c) Fire apparatus hydraulic fluid
d) Gear oil
Rationale: Fire apparatus hydraulic fluid is specifically formulated to
provide the proper viscosity and performance in aerial devices. 3 / 4
- Which inspection item is most critical before operating a ladder on an
aerial apparatus?
a) Fuel level
b) Hydraulic cylinder and hoses for leaks
c) Tire tread depth
d) Engine oil level
Rationale: Leaks in hydraulic components can cause ladder collapse or
uncontrolled movement, making inspection essential.
- Which component controls the speed of a fire pump relative to engine
RPM?
a) Pump intake gauge
b) Primer
c) Pump governor
d) Pump panel switch
Rationale: The pump governor maintains the desired pump pressure by
regulating engine RPM during pumping operations.
- What is the primary purpose of a booster tank on a fire
apparatus?
a) Store fuel
b) Provide an immediate water supply
c) Supply hydraulic fluid
d) Reduce pump wear
- / 4