- Which of the following is the primary purpose of a building code?
- To increase construction costs
- To regulate contractor wages
- To ensure public health, safety, and welfare
- To dictate interior design preferences
Rationale: Building codes are established to protect public health, safety,
and welfare by setting minimum standards for construction.
- What is the maximum allowable height of a guardrail in a commercial
- 30 inches 1 / 4
building according to most codes?
- 32 inches
- 42 inches
- 48 inches
Rationale: Most codes, including the IBC, require guardrails to be a
minimum of 42 inches high to prevent falls.
- Which type of construction is considered Type I under the IBC?
- Wood-frame
- Ordinary masonry
- Fire-resistive
- Heavy timber
Rationale: Type I construction is fire-resistive, using noncombustible
materials with high fire-resistance ratings.
- In a commercial building, what is the minimum clear width of an
- 28 inches
- 36 inches
- 32 inches
- 42 inches
accessible route?
Rationale: The IBC requires a minimum clear width of 36 inches for
accessible routes to accommodate wheelchairs.
- Which of the following is the most critical factor in determining the
design live load of a commercial floor? 2 / 4
- Roof slope
- Wall material
- Occupancy type
- Exterior finishes
Rationale: Live loads vary based on building use, so occupancy type
determines the floor’s load requirements.
- What is the minimum required fire-resistance rating for a floor
- 1 hour
- 1.5 hours
- 2 hours
- 3 hours
assembly in a Type I commercial building?
Rationale: Type I construction requires noncombustible assemblies with a
minimum 2-hour fire-resistance rating for floors.
- In commercial buildings, smoke detectors must be interconnected so
that:
- Only one alarm sounds at a time
- The system can be manually controlled
- Activation of one detector triggers all alarms
- Detectors operate only when sprinklers activate
Rationale: Interconnected smoke detectors ensure building occupants are
alerted wherever a fire is detected. 3 / 4
- Which type of sprinkler system is most commonly used in commercial
- Dry pipe
- Pre-action
- Wet pipe
- Deluge
office buildings?
Rationale: Wet pipe systems are the most common in commercial buildings
due to reliability and simplicity.
- When inspecting egress doors, what is the maximum allowable force
- 10 pounds
- 12 pounds
- 15 pounds
- 20 pounds
to open the door?
Rationale: The IBC limits door opening force to 15 pounds to ensure safe
egress during emergencies.
10. Fire-resistive ratings for walls are typically expressed in:
- Minutes
- Hours
- Days
- Years