- What is the nominal voltage of a fully charged 12-volt lead-acid battery
- 11.8 volts
- 12.6 volts
- 13.2 volts
- 12.0 volts
at rest?
Rationale: A fully charged 12V lead-acid battery measures around 12.6V
open-circuit. Lower readings indicate partial discharge. 1 / 4
- Which wire color is typically used for DC negative in a marine system per
ABYC E-11?
- Green
- Yellow or black
- Red
- White
Rationale: ABYC E-11 allows yellow or black for DC negative conductors to
avoid confusion with AC hot wires.
3. The primary function of a galvanic isolator is to:
- Reduce shore power current
- Increase grounding resistance
- Prevent galvanic corrosion through AC grounding path
- Disconnect batteries automatically
Rationale: A galvanic isolator blocks DC galvanic currents on the AC
grounding conductor while allowing fault current to pass.
- What is the minimum rating for overcurrent protection on a 12 AWG
wire rated for 30A continuous load?
A. 15A
B. 20A 2 / 4
C. 30A
D. 40A
Rationale: The overcurrent device must not exceed the wire’s ampacity; 12
AWG marine wire is rated for 30A.
- What does ABYC require for battery terminal protection?
- No requirement
- Plastic caps optional
- Protection against accidental shorting
- Only positive terminals covered
Rationale: Battery terminals must be protected to prevent accidental
contact or short-circuit.
6. The American Wire Gauge (AWG) system defines wire size based on:
- Diameter
- Cross-sectional area
- Weight
- Resistance only
Rationale: AWG correlates inversely with conductor cross-sectional area;
smaller gauge numbers mean larger wires.
- / 4
7. The primary purpose of a bonding system is to:
- Reduce voltage drop
- Equalize electrical potential between metal parts
- Improve radio reception
- Increase hull conductivity
Rationale: Bonding connects metallic components to maintain equal
potential, preventing stray current corrosion.
8. According to ABYC, AC and DC wiring systems should:
- Be run together in same conduit
- Be physically separated
- Use same color code
- Share overcurrent devices
Rationale: ABYC requires separation of AC and DC conductors to avoid
induced currents and confusion.
- When testing a shore power circuit, which fault would a reverse polarity
- Open neutral
- Hot and neutral reversed
- Neutral and ground bonded
- Low voltage
- / 4
indicator detect?