- What is the primary purpose of a fire alarm system?
- To detect burglaries
- To detect fires and alert occupants
- To control building lighting
- To regulate HVAC systems
- To detect fires and alert occupants
Rationale: The main purpose of a fire alarm system is to detect fire-related
hazards early and provide warnings to occupants to facilitate safe evacuation.
- Which component of a fire alarm system senses smoke or heat?
- Control panel
- Notification appliance
- Initiating device
- Power supply
- Initiating device
Rationale: Initiating devices, such as smoke detectors and heat detectors,
sense fire conditions and trigger the alarm system.
- What is the maximum spacing for a ceiling-mounted smoke detector in
a standard room according to NFPA 72? 1 / 3
- 10 feet
- 30 feet
- 50 feet
- 75 feet
- 30 feet
Rationale: NFPA 72 specifies that ceiling-mounted smoke detectors should
generally be spaced no more than 30 feet apart to ensure adequate coverage.
- Which voltage class does a low-voltage fire alarm system typically
use?
A. 120 V AC
B. 240 V AC
C. 24 V DC
D. 480 V AC
C. 24 V DC
Rationale: Low-voltage fire alarm systems commonly operate on 24 volts
DC for safety and compatibility with signaling devices.
- What is the purpose of a notification appliance in a fire alarm system?
- To detect smoke
- To alert occupants of a fire
- To control the HVAC
- To reset the system
- To alert occupants of a fire
Rationale: Notification appliances such as horns, bells, and strobes alert
building occupants when the fire alarm is activated.
- Which standard governs fire alarm system installation in the United
- NEC Article 250
States?
B. NFPA 72
C. OSHA 1910
D. ANSI Z535 2 / 3
B. NFPA 72
Rationale: NFPA 72 is the National Fire Alarm and Signaling Code that
sets standards for the design, installation, and maintenance of fire alarm systems.
- In a conventional fire alarm system, what does each zone represent?
- A separate building
- A group of initiating devices
- A type of notification appliance
- The control panel location
- A group of initiating devices
Rationale: Each zone in a conventional system groups initiating devices to
identify the general location of a fire.
- What is the primary difference between conventional and addressable
- Voltage used
- Device color
- Ability to identify individual devices
- Power supply type
- Ability to identify individual devices
fire alarm systems?
Rationale: Addressable systems can identify the exact device that triggered
the alarm, whereas conventional systems only indicate the zone.
- Which component provides backup power to a fire alarm system during
- Battery
- Transformer
- Relay
- Resistor
- Battery
a power outage?
Rationale: Batteries in fire alarm systems ensure operation during power
failures, maintaining system reliability.
- / 3