Florida Access Control Systems Contractor Exam Questions And Correct Answers (Verified Answers) Plus Rationale2026 Q&A| Instant Download Pdf
1.Which NEC article primarily governs access control system wiring under limited-energy circuits?
- Article 300
- Article 725
- Article 430
- Article 760
Answer: B
Rationale: Access control systems typically operate on Class 2 or 3 power-
limited circuits, which fall under NEC Article 725.
2.In an access-controlled egress door, which device must release the lock upon fire alarm activation?
- Door position switch
- Electric strike
- Magnetic lock
- Request-to-exit (REX) sensor
Answer: C
Rationale: Magnetic locks must release when the fire alarm activates to
allow free egress. 1 / 3
3.A card reader placed outdoors should have at least which IP rating?
A. IP20
B. IP44
C. IP54
D. IP65
Answer: D
Rationale: IP65 ensures dust protection and protection against water jets,
suitable for exposed environments.
4.Which Florida code regulates means of egress for access control systems?
- FBC Mechanical
- FBC Existing Building
- FBC Building
- FBC Plumbing
Answer: C
Rationale: Egress requirements for electronically controlled doors appear
in the Florida Building Code – Building.
5.Which voltage is most common for door access control power supplies?
A. 12 VDC
B. 48 VDC
C. 120 VAC
D. 6 VAC
Answer: A
Rationale: Most access control locking hardware and readers operate on 12
VDC.
6.
A fail-safe lock will:
- Lock when power is applied
- Unlock when power is lost 2 / 3
- Stay locked at all times
- Require a key to unlock only
Answer: B
Rationale: Fail-safe devices unlock during power loss for life-safety
requirements.
7.What is the primary purpose of a door position switch?
- Detect motion
- Detect if the door is open or closed
- Energize the lock
- Trigger alarms on fire
Answer: B
Rationale: DPS devices monitor door state for intrusion and access control
logic.
8.Which type of cable is most common for Wiegand reader connections?
- Coaxial
- Multi-conductor shielded
- Fiber optic
- Twin axial
Answer: B
Rationale: Wiegand interfaces use shielded multi-conductor cable to
reduce noise.
9.Under NEC, what is the maximum voltage for a Class 2 circuit?
A. 12 V
B. 30 V
C. 150 V
D. 600 V
Answer: B
Rationale: Class 2 circuits are limited to 30 volts for safety.