Contractor Exam Questions And Correct

Class notes Jan 3, 2026 ★★★★☆ (4.0/5)
Loading...

Loading document viewer...

Page 0 of 0

Document Text

CA D62 Air And Water Balancing Contractor Exam Questions And Correct Answers (Verified Answers) Plus Rationale2026 Q&A| Instant Download Pdf

  • What is the primary purpose of air balancing in HVAC systems?
  • Reduce energy costs
  • Improve system aesthetics
  • Ensure proper airflow to all areas
  • Increase humidity levels

Rationale: Proper air balancing ensures each space receives the

correct airflow as designed for comfort and system efficiency.

  • What instrument is typically used to measure air velocity in ducts?
  • Thermometer
  • Anemometer
  • Manometer
  • Hygrometer

Rationale: Anemometers are specifically designed to measure air

velocity, which is crucial for balancing airflow.

  • In water system balancing, what is the main parameter to measure?
  • Water color
  • pH level
  • Flow rate
  • Temperature

Rationale: Flow rate is measured to ensure each branch of the system

receives the correct amount of water for proper operation.

  • What does a manometer measure?
  • Air temperature
  • Electrical resistance
  • Pressure differences 1 / 3
  • Relative humidity

Rationale: Manometers measure pressure differences, which are

critical in diagnosing airflow or water pressure issues.

  • Which of the following is a common method for air balancing?
  • Color matching
  • Duct traverse
  • Water sampling
  • Pipe insulation

Rationale: Duct traverse involves measuring airflow at multiple

points across a duct to determine proper balancing.

  • What is the main effect of an unbalanced air system?
  • Lower energy costs
  • Uneven temperature distribution
  • Improved air quality
  • Reduced noise

Rationale: An unbalanced system causes some areas to be too hot or

cold because airflow is not properly distributed.

  • What is the purpose of a flow hood in air balancing?
  • Increase airflow
  • Measure duct pressure
  • Measure airflow at diffusers and grilles
  • Reduce duct leakage

Rationale: Flow hoods capture and measure air exiting diffusers to

confirm the system delivers design airflow.

  • Which factor affects water flow in hydronic systems?
  • Pipe color
  • Water temperature
  • Pipe diameter and valve settings
  • Humidity

Rationale: Pipe diameter and valve settings directly control water

flow and distribution in a system.

  • What unit is airflow commonly measured in?
  • Gallons per minute (GPM)
  • Pounds per square inch (PSI)
  • Cubic feet per minute (CFM)
  • BTU/hr 2 / 3

Rationale: Airflow in HVAC systems is measured in CFM to quantify

the volume of air moving through the system.

  • What is the typical method to balance a fan coil unit?
  • Adjust thermostat
  • Adjust valves to achieve design flow
  • Replace filters
  • Paint coils

Rationale: Balancing fan coil units involves adjusting water or air

valves to ensure each unit receives the correct flow.

  • What instrument is used to measure water pressure in a hydronic
  • system?

  • Thermocouple
  • Hygrometer
  • Pressure gauge
  • Anemometer

Rationale: Pressure gauges are standard instruments to measure

water pressure in piping systems.

  • What is the effect of oversized ducts on airflow?
  • Increase velocity
  • Reduce noise
  • Reduce velocity and potential system efficiency
  • Improve system control

Rationale: Oversized ducts reduce air velocity, which can cause poor

mixing and uneven distribution.

  • Which is a common sign of an unbalanced water system?
  • Corrosion in pipes
  • Excessive noise only
  • Some radiators or terminals too hot or cold
  • Low water pH

Rationale: Uneven heating or cooling across terminals indicates

improper water distribution and balancing issues.

  • What is the purpose of an orifice plate in water systems?
  • Measure temperature
  • Filter impurities
  • Restrict flow for measurement and balancing
  • Increase pressure
  • / 3

User Reviews

★★★★☆ (4.0/5 based on 1 reviews)
Login to Review
S
Student
May 21, 2025
★★★★☆

With its practical examples, this document enhanced my understanding. Definitely a outstanding choice!

Download Document

Buy This Document

$1.00 One-time purchase
Buy Now
  • Full access to this document
  • Download anytime
  • No expiration

Document Information

Category: Class notes
Added: Jan 3, 2026
Description:

CA D62 Air And Water Balancing Contractor Exam Questions And Correct Answers (Verified Answers) Plus Rationale2026 Q&A| Instant Download Pdf 1. What is the primary purpose of air balancing in HVAC ...

Unlock Now
$ 1.00