Texas Mold Assessment Consultant Exam Actual Exam Latest Update - 150 Questions and 100% Verified Correct Answers Guaranteed A+
A fee of blank is required for any routine licensing examination or re-examination -
CORRECT ANSWER: $60
A license holder overseeing mold related activities, with exception of activities performed by a mold analysis laboratory, must ensure that a client is provided a copy of
the department consumer mold information sheet - CORRECT ANSWER: prior to the
initiation of any mold related activity
A mold remediation contractor or company shall notify the department of a mold remediation project - CORRECT ANSWER: no less than five working days prior to the anticipated start date of the activity
a musty odor indoors usually indicates - CORRECT ANSWER: microbial growth
a person is not required to be licensed under the Texas Malta settlement and remediation rules, to perform mold remediation in an area in which the mold contamination for the project affects a total surface area of - CORRECT ANSWER: less than 25 contiguous square feet
a spore trap sample is collected at a flow rate of 15 L per minute for seven minutes.
What is the sample volume - CORRECT ANSWER: 105 L
According to Table 2 of the EPA is mold remediation in schools in commercial buildings, if the total surface area affected is greater than 100 ft.² the recommended PPE is - CORRECT ANSWER: gloves, disposable full body clothing, headgear, foot coverings, full face respirator with HEPA filter
according to table 2 of the EPA's mold remediation in schools and commercial buildings, it is an recommended that a contaminated area of 25 contiguous square feet have
which of the following containments - CORRECT ANSWER: polyethylene sheeting
ceiling to floor around affected area with a slit entry and covering flat; maintaining area under negative pressure with HEPA filtered fan unit. Block supply and return air vents within the contaminated area
according to table one of the EPA's mold remediation in schools of commercial buildings, if clean water damage has occurred within 24 hours to 48 hours, it is
recommended that cellulose insulation be - CORRECT ANSWER: discarded and
replaced
- / 2
according to table one of the EPA's mold remediation in schools of commercial buildings, if clean water damage has occurred within 24 to 48 hours is recommended
that wallboard (drywall and gypsum) be - CORRECT ANSWER: dried in place if no
swelling has occurred and seems are intact
according to table. 2 of the EPA's "Mold remediation in schools and commercial buildings, the containment recommended for a contaminated area of less than 10 ft.² is -
CORRECT ANSWER: none
according to table. 2 of the EPA's "Mold remediation in schools and commercial buildings", it is recommended that a carpeted area of 50 square feet that has mold
contamination from clean water should be - CORRECT ANSWER: wet vacuumed,
HEPA vacuumed or discarded well-sealed plastic bags
According to the EPA is mold remediation in schools and commercial buildings, if the
total surface area by mold is 25 ft.² the recommended PPE is - CORRECT ANSWER:
Limited and full
according to the EPA is mold remediation in schools in commercial buildings, the HVAC filters during remediation should have a minimum MERV rating of - CORRECT
ANSWER: eight
according to the EPA mold remediation in schools in commercial buildings, it is recommended that wood surfaces that have mold growth caused by Clearwater be -
CORRECT ANSWER: wet vacuumed / HEPA vacuumed / damp wiped /Discarded
according to the EPA's "mold remediation in schools and commercial buildings" document, the EPA recommends the following for cleanup for non-porous hard surface
areas - CORRECT ANSWER: cleaned with detergent solution
according to the EPA's mold remediation in schools and commercial buildings, the recommended clean up method for books and papers with mold growth is - CORRECT
ANSWER: thoroughly dry then HEPA vacuum
according to the EPA's mold remediation in schools and commercial buildings, the
recommended containment type is based on the - CORRECT ANSWER: Area of mold
growth
according to the EPA's mold remediation in schools and commercial buildings, within forty eight hours of damage by clean water it is recommended that - CORRECT ANSWER: a carpet may be dried / wallboard maybe dried if there is no swelling / cellulose insulation should be discarded
according to the EPA's mold remediation in schools in commercial buildings, it is recommended that concrete or cinderblock surfaces that have mold growth caused by clean water be - CORRECT ANSWER: wet vacuumed and HEPA vacuumed