What is the best way for steel girders (I-beams) in basement concrete wall pockets to be installed?
- Lay on tar paper
- 1/2" gap on three sides
- Lay on poly sheeting
- Lay on wood shims - ---Answers----b. 1/2" gap on three
sides
How are hurricane ties attached at the roof structure?
- Joist to rafter
- Inside edge of top plate to rafter
- Outside edge of top plate
- Stud to top plate - ---Answers----b. Inside edge of top plate
to rafter
CDX is what type material?
- Exterior grade plywood
- Interior grade plywood
- Paint grade plywood
- Oriented strand board - ---Answers----a. Exterior grade
plywood 1 / 4
Step cracks in a masonry wall at the top corner of a window angled up and away are caused by?
- Rusted lintel
- Settled header
- Rusted hurricane ties
- Poor window installation - ---Answers----a. Rusted lintel
A standard air conditioning system can easily be converted to a heat pump by the addition of a few key components.
- True
- False - ---Answers----b. False
An accumulator prevents what from entering the compressor?
- Water
- Liquid refrigerant
- Oil
- Gaseous refrigerant - ---Answers----b. Liquid refrigerant
In a heat pump during the cooling cycle, which coil acts as the evaporator? In the heating cycle, which coil acts as the evaporator?
- Indoor/Outdoor 2 / 4
- Outdoor/Indoor
- Indoor/Indoor
- Outdoor/Outdoor - ---Answers----a. Indoor/Outdoor
The ___ _____directs hot refrigerant to the indoor coil in the _____cycle in a heat pump.
- Multi-cycle valve - heating
- Reversing valve - cooling
- Reversing valve - heating - ---Answers----c. Reversing
valve - heating
Under certain operating conditions, _____ will form on the outdoor coil. This can cause a/an ____ in efficiency.
- Moss - increase
- Frost - decrease
- Frost - increase
- Mold - decrease - ---Answers----b. Frost - decrease
The defrost cycle is initiated by ____ and ____.
- Homeowner and temperature
- Time and temperature
- Time and humidity
- Temperature and humidity - ---Answers----b. Time and
- / 4
temperature
The most common cause of insufficient airflow in an A/C system is?
- Dirty coil
- Dirty filter
- Oversized ducts
- Both a and b - ---Answers----d. Both a and b
Ductwork should be ____ enough to handle the volume of air needed for correct A/C operation.
- Large
- Small
- Square
- Round - ---Answers----a. Large
In heavy snowfall areas, it is good practice to mount the heat pump's outdoor unit on a/an _____ to prevent snow from blocking the coil.
- Wood platform
- Concrete platform
- Elevated platform
- Plastic platform - ---Answers----c. Elevated platform
Why are heat pumps labeled not to be operated unless power is on for a minimum of
- / 4