Florida Certified Journeyman Electrician Exam Questions And Correct Answers (Verified Answers) Plus Rationale2026 Q&A| Instant Download Pdf
- What is the minimum size copper grounding electrode conductor for a
200-amp residential service?
A. 4 AWG
B. 6 AWG
C. 4 AWG
D. 2 AWG
Rationale: NEC 250.66 requires 4 AWG copper for 2/0 service
conductor sizing typical for 200-amp services.
2.What is the standard nominal voltage for a single-phase residential system in Florida?
A. 120/480 V
B. 120/240 V
C. 240/480 V
D. 208/120 V
Rationale: 120/240 V is the standard split-phase service for dwellings.
- / 3
3.
Minimum burial depth for PVC conduit under a residential driveway is:
- 6 inches
- 12 inches
- 18 inches
- 24 inches
Rationale: NEC Table 300.5 requires 24 inches under residential driveways
for PVC.
4.Maximum number of 90-degree bends allowed in one conduit run without a pull point?
- 180 degrees
- 360 degrees
- 270 degrees
- 450 degrees
Rationale: NEC 358.26 limits total bends to 360 degrees.
5.Type of breaker required for bedroom circuits?
A. GFCI
- Standard
C. AFCI
D. HACR
Rationale: NEC 210.12 requires AFCI protection in bedrooms.
6.Minimum height of receptacle outlets above countertops in kitchens?
- 8 inches 2 / 3
- 10 inches
- Not specified by NEC
- 14 inches
Rationale: NEC has no minimum height requirement, only spacing
requirements.
7.What is the color for the grounded conductor?
- Red
- Blue
- White or gray
- Yellow
Rationale: NEC 200.6 defines grounded conductor color coding.
8.GFCI protection is required for receptacles within how many feet of a sink?
- 3 ft
- 6 ft
- 8 ft
- 10 ft
Rationale: NEC 210.8 requires GFCI within 6 ft of water source.
9.Minimum working clearance in front of 600-V electrical equipment?
- 24 inches
- 36 inches
- 48 inches
- 60 inches
- / 3
Rationale: NEC 110.26(A)(1) requires 3 ft working clearance.