VERSION 1
The chemical symbol for lead is - ANSWER-Pb
As a qualified and trained lead inspector, you should be very suspect of housing units built before due to the fact that the very well may contain some lead-based paint - ANSWER-1978
EPA Soil Regulations - ANSWER-- 400 ppm for playgrounds/children's areas - 1200 ppm for rest of yard - There must be 9 sq ft of soil to classify with soil testing
- At 5000 ppm, MUST remediate/abate (remove & replace, paving, or
bioremediation)
THE NLLAP for laboratories was established by - ANSWER-EPA
Which governmental agency has taken action to virtually remove lead from
gasoline products: - ANSWER-NIOSH
In what year did the Federal Government enact the Lead-Based Paint Poisoning
Prevention Act (LBPPPA): - ANSWER-1971
- / 4
What is the common source of lead poisoning in children: - ANSWER-lead-based
paint dust
OSHA Lead Standards for exposures above the action level require: - ANSWER-
exposure monitoring, medical surveillance, and medical removal
The basic Federal Law governing waste disposal is known as: - ANSWER-RCRA
When conducting an LBP survey, if two components of the same type have or are
suspected to have a different painting history: - ANSWER-both must be tested
An XRF analyzer works by exposing a paint surface to radiation emitted from a seated source inside the instrument. The source of this radiation is generally known as - ANSWER-cobalt or cadmium
Title X was issued in 1992 by - ANSWER-HUD?
Any certified lead inspector is VERY careful when handling an XRF analyzer.Great care should be taken not to ________ due to the fact that the instrument contains a verified source of radioactive material. - ANSWER-All of the above
How often should a wipe test be taken on the surface of the XRF and analyzed for radioactive levels - ANSWER-Every 3 years?
An XRF analyzer instrument is a technically complicated tool. Under no
circumstances should one: - ANSWER-tamper with or attempt to replace the
radiation source
Exposure to radiation is affect by: - ANSWER-STD 2 / 4
Lead is one of the following - ANSWER-a heavy metal
Even with the safe use of radioactive material, the possible risk of exposure requires that inspectors be proactive in protecting themselves. Therefore, OSHA
recommends that all inspectors using an XRF analyzer wear: - ANSWER-
dosimeters
What shell bonds to the nucleus the greatest? - ANSWER-K shell
The NIST Standard of reference material that is closest to 1.0 mg/cm2 is? - ANSWER-Yellow
In a 4 hour inspection, how often must you perform calibration check(s) of your XRF analyzer? - ANSWER-Once
mg/cm2 is the scientific symbol for: - ANSWER-milligram per sqaured centimeter
Lead has been used for: - ANSWER-All of the above
In a 10 hour inspection, a lead paint inspector must perform a minimum of __ calibration checks - ANSWER-4
For buildings that have been built prior to 1960 with 1040 or more similar units, the inspector must test what percentage of the units common areas and exterior sites? - ANSWER-5.7 (chart)
- / 4
During the Roman Empire, lead production was estimated at ___ tons per year - ANSWER-80,000 tons
For buildings that have been built prior to 1960-1977 with 1000 or more similar units the inspector must test what percent of the units common areas and exterior sites? - ANSWER-2.9
Which of the following does HUD not consider a recognized substrate? - ANSWER-Paper
The major source of lead for most adults is: - ANSWER-occupational exposure
Lead causes permanent damage to: - ANSWER-All of the above
Which of the following is THE MAIN hazard for children's lead poisoning: -
ANSWER-exposure through dust and soil
What is the source of radiation in all XRF Analyzers used to test lead based paint?
- ANSWER-Cobalt-57 AND Cadmium-109
Due to discrepancies of regulations, many inspectors encounter difference between federal, state, or local, standards. The "rule of thumb" is to: - ANSWER-comply with more stringent standards
What is emitted from radioactive sourec in the XRF: - ANSWER-Gamma rays
The decay rate of cobalt-57 is approximately: - ANSWER-9 months