Waterproofing Technician Certification Exam 100 Practice Questions And Correct Answers (Verified Answers) Plus Rationales 2026 Q&A | Instant Download Pdf
- What is the primary purpose of waterproofing in construction?
- Improve aesthetics
- Reduce thermal conductivity
- Protect structures from water intrusion
- Strengthen structural members
- Protect structures from water intrusion
Rationale: Waterproofing prevents moisture penetration that can damage
structural and interior components.
- Which membrane type is commonly torch-applied?
A. PVC
B. TPO 1 / 4
C. EPDM
- Modified bitumen
- Modified bitumen
Rationale: Torch application is standard for modified bitumen membranes.
- Which test measures concrete moisture vapor emission rate?
- Blaine test
- Calcium chloride test
- Slump test
- Compression test
- Calcium chloride test
Rationale: This test quantifies moisture vapor emission from concrete
slabs.
- A below-grade foundation wall requires which waterproofing approach?
- Surface sealer only
- Vapor retarder only
- Continuous membrane with drainage
- Interior paint coating
- Continuous membrane with drainage
Rationale: Below-grade areas must combine waterproofing with drainage
to control hydrostatic pressure.
- Which membrane is fully adhered using solvent-based adhesive? 2 / 4
A. EPDM
- Bentonite
- Hot-applied rubberized asphalt
- Polyurethane foam
A. EPDM
Rationale: EPDM sheets are commonly bonded with solvent-based or
water-based adhesives.
6. Hydrostatic pressure occurs when:
- Water evaporates rapidly
- Soil dries out
- Groundwater pushes against the structure
- Air pressure exceeds water pressure
- Groundwater pushes against the structure
Rationale: Hydrostatic pressure results from standing water exerting force
on a structure.
- Which material expands when hydrated and is used for self-sealing
- Acrylic
- Bentonite
- Silicone
- Polysulfide
- Bentonite
applications?
Rationale: Bentonite clay swells when wet, sealing gaps automatically. 3 / 4
8. A key advantage of liquid-applied membranes is:
- Requires heat for installation
- Automatically forms seams
- Seamless application
- Only usable indoors
- Seamless application
Rationale: Liquid membranes cure as a continuous, joint-free barrier.
- What is the minimum recommended slope for a low-slope roof?
- 0%
B. 0.25:12
C. 0.5:12
D. 2:12
C. 0.5:12
Rationale: A minimum slope of 0.5:12 ensures proper drainage.
- Which instrument detects leaks in roofing systems?
- Refractometer
- Moisture meter
- Thermometer
- Tensiometer
- Moisture meter
Rationale: Moisture meters measure trapped moisture to identify leak
paths.
- / 4