• wonderlic tests
  • EXAM REVIEW
  • NCCCO Examination
  • Summary
  • Class notes
  • QUESTIONS & ANSWERS
  • NCLEX EXAM
  • Exam (elaborations)
  • Study guide
  • Latest nclex materials
  • HESI EXAMS
  • EXAMS AND CERTIFICATIONS
  • HESI ENTRANCE EXAM
  • ATI EXAM
  • NR AND NUR Exams
  • Gizmos
  • PORTAGE LEARNING
  • Ihuman Case Study
  • LETRS
  • NURS EXAM
  • NSG Exam
  • Testbanks
  • Vsim
  • Latest WGU
  • AQA PAPERS AND MARK SCHEME
  • DMV
  • WGU EXAM
  • exam bundles
  • Study Material
  • Study Notes
  • Test Prep

EXAM 300 QUESTIONS AND CORRECT

Exam (elaborations) Dec 15, 2025 ★★★★★ (5.0/5)
Loading...

Loading document viewer...

Page 0 of 0

Document Text

ARDMS Davies Breast Sonography ACTUAL

EXAM 300 QUESTIONS AND CORRECT

ANSWERS -

Which artifact may cause structures to look deeper than they actually are?

  • Side lobe
  • Shadowing
  • Refraction
  • Propagation speed error
  • Slice thickness - CORRECT ANSWER-D. propagation speed error

The optimum operating frequency for a broad-bandwidth transducer would

be:

  • 6 MHz
  • 7 MHz
  • 8 MHz
  • 9 MHz
  • 10 MHz - CORRECT ANSWER-C. 8

In breast sonography, which of the following is NOT significantly affected by the limited field of view when imaging superficial structures?

  • Contrast resolution
  • Spatial resolution
  • Axial resolution
  • Lateral resolution
  • Temporal resolution - CORRECT ANSWER-E. temporal resolution

Which of the following affects the actual intensity of the sound utilized for imaging?

A. TGC

  • Output power
  • Overall gain
  • Dynamic range
  • Harmonics - CORRECT ANSWER-B. output power 1 / 4

The dynamic range of a display is the:

A, Number of gray shades

  • Depth of focal zone
  • Intensity of sound utilized
  • Image scale
  • Output power - CORRECT ANSWER-A. number of gray shades

6.Using color/power Doppler while a patient hums to better delineate a mass is called:

  • Aliasing
  • Spectral mirroring
  • Ring-down
  • Harmonics
  • Fremitus - CORRECT ANSWER-E. fremitus

7. A standoff pad thicker than 1 cm is NOT recommended because it will:

  • Make the skin line look thicker than normal.
  • Affect the optimal placement of the fixed elevation plane focus.
  • Compress the mammary layer and make it look fibrotic.
  • Cause enhancement of echoes in the mammary zone.
  • Cause decreased penetration and an inability to see the chest wall. - CORRECT ANSWER-B. affect
  • the optimal placement of the fixed elevation plane focus

Which type of transducer does NOT allow the sonographer to vary the focusing capabilities?

  • Electronic linear array
  • Electronic convex array
  • Annular array
  • Mechanical sector
  • Electronic sector - CORRECT ANSWER-D. mechanical sector
  • / 4
  • When taking patient history for a breast sonogram, what information from a
  • previous mammogram would NOT be considered relevant?

  • Symmetry of breasts
  • Location of a questionable lesion
  • Size of a questionable lesion
  • Date and results of a previous mammogram
  • Name of the radiographer - CORRECT ANSWER-E. Name of radiologist

10. Image amplitude is affected by:

  • Power
  • Overall gain
  • Time gain compensation (TGC)
  • A and B
  • A, B, and C - CORRECT ANSWER-E. Power, TGC, Overall gain
  • High-frequency transducers used in breast imaging provide excellent

resolution of breast tissues but limited:

  • Focusing options
  • Gain adjustment
  • Penetration
  • Gray scale
  • Scan lines - CORRECT ANSWER-C. penetration

2. When using the 123-ABC method of annotation, "B" would indicate:

  • Mass is close to the nipple.
  • Mass is medium shade of gray
  • Mass is in the mammary zone.
  • Mass is benign.
  • Mass requires biopsy. - CORRECT ANSWER-C. mass is in the mammary zone
  • In the 123-ABC method of annotation, the numbers denote the: 3 / 4
  • Distance from nipple
  • Depth of the mass
  • Number of masses
  • Stage of cancer
  • Sequence of imaging - CORRECT ANSWER-A. distance from nipple
  • Which method of patient positioning is best for evaluating the medial aspect of the breast?
  • Posterior oblique
  • Lateral decubitus
  • Upright
  • D.Trendelenburg

  • Supine - CORRECT ANSWER-E. supine

15. The two-handed technique is used to image:

  • Both breasts at the same time
  • An extremely large breast
  • The main breast duct and nipple
  • Multiple masses within the breast
  • A palpable mass that is mobile - CORRECT ANSWER-C. the main breast duct and the nipple
  • Which of the following transducers would be the best choice for breast
  • imaging?

  • 5 MHz phased array
  • 3.5-5 MHz curved linear array
  • 8 MHz annular array
  • 10 MHz linear array
  • 12 MHz mechanical sector - CORRECT ANSWER-D. 10 MHz linear array

17. Selecting multiple focal zones will:

  • Decrease frame rate
  • Increase frame rate
  • / 4

User Reviews

★★★★★ (5.0/5 based on 1 reviews)
Login to Review
S
Student
May 21, 2025
★★★★★

The in-depth analysis offered by this document enhanced my understanding. A remarkable purchase!

Download Document

Buy This Document

$1.00 One-time purchase
Buy Now
  • Full access to this document
  • Download anytime
  • No expiration

Document Information

Category: Exam (elaborations)
Added: Dec 15, 2025
Description:

ARDMS Davies Breast Sonography ACTUAL EXAM 300 QUESTIONS AND CORRECT ANSWERS - Which artifact may cause structures to look deeper than they actually are? A. Side lobe B. Shadowing C. Refraction D. ...

Unlock Now
$ 1.00