NATE Gas Heating Service (Air) Exam (Latest Update 2026 / 2027) Questions and Verified Answers | 100% Correct | Grade A

Question:

How should a limit safe check be performed on a gas furnace

Answer:

Jump out the control for at least 10 min

Question:

How is an induced draft pressure switch tested for proper operation

Answer:

De energize the draft inductor motor and test the switch with a nanometer

  • / 4

Question:

Which of the following are input signals to a high efficiency furnace control board

Answer:

The pressure switch, the pilot valve and limit valve

Question:

Which of the following are output signals from a high efficiency furnace control board

Answer:

The thermostat, main gas valve, and igniter

Question:

Where should high efficiency condensing furnaces get their combustion air from

Answer:

From outside of the home only

  • / 4

Question:

Which of the following is not a cause of insufficient or low gas input

Answer:

A plugged orifice

Question:

A customer complains that there is not enough supply air coming through the registers Tech A checked the unit temp rise inspected the air filter and adjusted a loose fan belt

Tech B inspected the air filter observed the blower motor operation checked for duct obstructions and made sure that balancing dampers are in the correct position

Answer:

Tech B

  • / 4

Question:

Tech A was called because not enough heat was being generated at the furnace The tech checked the heat exchanger and flue pipe and burners. He also tested inlet and outlet gas pressure to the furnace. His measurement was 4" WC to the main gas valve and 2" WC out of the gas valve

Answer:

A faulty gas valve

Question:

Which of the following would not be a cause of a faulty thermostat on a standing pilot furnace

Answer:

The furnace is short cycling

Question:

A new high-efficiency furnace has been installed, and the furnace seems to come on too often. Which of the following would most likely be the problem?

Answer:

Improper selection made of the dip

  • / 4

User Reviews

★★★★★ (5.0/5 based on 1 reviews)
Login to Review
S
Student
May 21, 2025
★★★★★

The detailed explanations offered by this document was a perfect resource for my project. A remarkable purchase!

Download Document

Buy This Document