Wisconsin Dwelling Contractor Qualifier Exam Practice Questions And Correct Answers (Verified Answers) Plus Rationales 2026 Q&A | Instant Download Pdf
- Which of the following is the primary purpose of the Wisconsin
- To regulate commercial building construction
- To ensure the safety, health, and welfare of dwelling occupants
- To control zoning and land use
- To manage environmental impact assessments
- To ensure the safety, health, and welfare of dwelling occupants
Uniform Dwelling Code (UDC)?
Rationale: The UDC establishes minimum standards for residential
construction to protect the safety, health, and welfare of occupants. 1 / 4
- When must a dwelling contractor obtain a permit before starting
- Only for electrical work
- Only for projects over $50,000
- Before beginning any construction, alteration, or repair regulated by
- Only for structural alterations
- Before beginning any construction, alteration, or repair regulated by the
work?
the UDC
UDC
Rationale: Permits ensure that all work meets the UDC standards and is
inspected for compliance.
- What is the minimum required ceiling height for habitable rooms in a
- 6 feet 6 inches
- 7 feet 0 inches
- 7 feet 6 inches
- 8 feet 0 inches
- 7 feet 0 inches
dwelling under the Wisconsin UDC?
Rationale: UDC specifies a minimum ceiling height of 7 feet for habitable
rooms to ensure adequate living space.
- Which type of insulation is generally required in exterior walls of new
dwellings?
A. R-11 2 / 4
B. R-13
C. R-19
D. R-21
B. R-13
Rationale: UDC specifies R-13 insulation for 2x4 exterior walls in new
dwellings to meet thermal efficiency requirements.
- What is the maximum spacing allowed for wood floor joists supporting
- 12 inches on center
- 16 inches on center
- 24 inches on center
- 32 inches on center
- 16 inches on center
a typical residential floor?
Rationale: Standard residential floor joist spacing is 16 inches on center to
provide adequate structural support.
- Which of the following is required for egress windows in a basement
- Minimum 20 inches width
- Minimum 5.7 square feet opening
- Minimum 18 inches height
- Maximum sill height of 72 inches 3 / 4
bedroom?
- Minimum 5.7 square feet opening
Rationale: UDC mandates a minimum net clear opening of 5.7 sq. ft for
emergency escape and rescue windows in basement bedrooms.
- How far must smoke alarms be installed from bathrooms containing a
- 3 feet
- 5 feet
- 10 feet
- 12 feet
- 3 feet
bathtub or shower?
Rationale: To reduce false alarms while still providing protection, smoke
alarms must be at least 3 feet from bathrooms with showers.
- Which of the following materials is NOT permitted for use as a
- Concrete block
- Pressure-treated wood
- Particleboard
- Poured concrete
- Particleboard
structural wall under the UDC?
Rationale: Particleboard is not permitted as a primary structural wall
material due to insufficient strength and moisture resistance.
- / 4